{"id":{"repo_id":"wilfrid-laurier","oai_identifier":"oai:scholars.wlu.ca:etd-4064"},"canonical_url":"https://search.ndltd.org/etd/wilfrid-laurier/oai:scholars.wlu.ca:etd-4064","repository":{"repo_id":"wilfrid-laurier","name":"Wilfrid Laurier University","base_url":"https://scholars.wlu.ca/do/oai/"},"display":{"title":"TaylorKAN-ViT: Parameter-Efficient Vision Transformers for Medical Image Classification","abstract":"Effective and interpretable classification of medical images remains a critical challenge in computer-aided diagnosis, particularly in data-scarce and resource-constrained clinical settings where traditional deep learning models prove impractical. This study addresses the fundamental barrier to Vision Transformer adoption in medical imaging—massive parameter counts and data requirements—through a systematic two-phase methodology. Phase 1 evaluates three spline-based Kolmogorov–Arnold Network (KAN) variants to identify the optimal nonlinear approximation function for parameter-efficient medical image classification: SBTAYLOR-KAN (B-splines with Taylor series), SBRBF-KAN (B-splines with Radial Basis Functions), and SBWAVELET-KAN (B-splines with Morlet wavelets). Comprehensive experiments across brain MRI, chest X-rays, and tuberculosis datasets—without any image preprocessing beyond the datasets' original published forms—establish SBTAYLOR-KAN as the superior architecture, achieving up to 98.93% accuracy with only 2,872 parameters (>99% reduction versus ResNet50's ~24.18M) while maintaining 86% accuracy using merely 30% training data. Statistical validation through kappa coefficients, Matthews correlation, and cross-dataset generalization confirms its robustness and data efficiency. Building directly on these findings, Phase 2 integrates the optimal Taylor-KAN formulation into a Vision Transformer architecture, yielding TaylorKAN-ViT—an ultra-compact model that fundamentally reimagines efficient transformer design through a KAN-first approach. Unlike conventional ViTs that retrofit parameter reduction techniques while retaining MLP-heavy architectures, TaylorKAN-ViT replaces all nonlinear feed-forward mappings with the Taylor-series-approximated KAN modules identified in Phase 1. This enables dual-scale feature learning: KAN transformations capture fine-grained local patterns within image patches, while self-attention mechanisms model long-range global dependencies across the entire image. Despite comprising only 88.9K parameters and 4.9G FLOPs—representing ~99.3% parameter reduction compared to recent medical ViTs (MedKAFormer-T: 12.47M, MedViTV2-T: 12.3M)—TaylorKAN-ViT achieves competitive performance across four diverse benchmarks: 94.36% accuracy on PneumoniaMNIST, 95.90% on CPNX-ray, 61.00% on PAD-UFES-20, and 70.50% on Kvasir. The model demonstrates stable generalization even under limited-data and class-imbalanced conditions. These results demonstrate that clinical-grade medical image classification is achievable without large-scale models, establishing TaylorKAN-ViT as a practical, deployable solution for edge devices, mobile platforms, and resource-limited healthcare environments.","abstract_html":"Effective and interpretable classification of medical images remains a critical challenge in computer-aided diagnosis, particularly in data-scarce and resource-constrained clinical settings where traditional deep learning models prove impractical. This study addresses the fundamental barrier to Vision Transformer adoption in medical imaging—massive parameter counts and data requirements—through a systematic two-phase methodology. Phase 1 evaluates three spline-based Kolmogorov–Arnold Network (KAN) variants to identify the optimal nonlinear approximation function for parameter-efficient medical image classification: SBTAYLOR-KAN (B-splines with Taylor series), SBRBF-KAN (B-splines with Radial Basis Functions), and SBWAVELET-KAN (B-splines with Morlet wavelets). Comprehensive experiments across brain MRI, chest X-rays, and tuberculosis datasets—without any image preprocessing beyond the datasets&#x27; original published forms—establish SBTAYLOR-KAN as the superior architecture, achieving up to 98.93% accuracy with only 2,872 parameters (&gt;99% reduction versus ResNet50&#x27;s ~24.18M) while maintaining 86% accuracy using merely 30% training data. Statistical validation through kappa coefficients, Matthews correlation, and cross-dataset generalization confirms its robustness and data efficiency. Building directly on these findings, Phase 2 integrates the optimal Taylor-KAN formulation into a Vision Transformer architecture, yielding TaylorKAN-ViT—an ultra-compact model that fundamentally reimagines efficient transformer design through a KAN-first approach. Unlike conventional ViTs that retrofit parameter reduction techniques while retaining MLP-heavy architectures, TaylorKAN-ViT replaces all nonlinear feed-forward mappings with the Taylor-series-approximated KAN modules identified in Phase 1. This enables dual-scale feature learning: KAN transformations capture fine-grained local patterns within image patches, while self-attention mechanisms model long-range global dependencies across the entire image. Despite comprising only 88.9K parameters and 4.9G FLOPs—representing ~99.3% parameter reduction compared to recent medical ViTs (MedKAFormer-T: 12.47M, MedViTV2-T: 12.3M)—TaylorKAN-ViT achieves competitive performance across four diverse benchmarks: 94.36% accuracy on PneumoniaMNIST, 95.90% on CPNX-ray, 61.00% on PAD-UFES-20, and 70.50% on Kvasir. The model demonstrates stable generalization even under limited-data and class-imbalanced conditions. These results demonstrate that clinical-grade medical image classification is achievable without large-scale models, establishing TaylorKAN-ViT as a practical, deployable solution for edge devices, mobile platforms, and resource-limited healthcare environments.","abstract_has_math":false,"creators":["Fatema, Kaniz","Mohammed, Dr. Emad","Sehra, Dr. Sukhjit Singh"],"institution":"Wilfrid Laurier University","degree_name":"Master of Applied Computing","degree_level":null,"degree_discipline":"Physics and Computer Science","degree_department":null,"school":null,"contributors":["Dr. Emad Mohammed","Dr. Sukhjit Singh Sehra"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-01-01T08:00:00Z","date_published":"2026-01-01T08:00:00Z","updated_at":"2026-11-18T22:09:03Z","subjects":["Kolmogorov–Arnold Network (KAN)","Taylor Series Approximation","TaylorKAN-ViT","Transformer Model","Small dataset","parameter efficiency.","Engineering","Life Sciences","Medicine and Health Sciences"],"languages":["en"],"rights":["2 Publicly accessible"],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://scholars.wlu.ca/etd/2901","outbound_label":"Repository record","outbound_source":"dc:identifier","record_url":"https://scholars.wlu.ca/etd/2901","record_label":"Repository record","record_kind":"record","record_source":"dc:identifier","download_url":"https://scholars.wlu.ca/context/etd/article/4064/viewcontent/Kaniz_Fatema_TaylorKAN_ViT_Final.pdf","download_label":"Download PDF","download_source":"dc:identifier","access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://scholars.wlu.ca/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Ascholars.wlu.ca%3Aetd-4064","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dr. Emad Mohammed","Dr. Sukhjit Singh Sehra"]},{"key":"dc:contributor.role","label":"Dc Contributor Role","values":["Supervision, Formal analysis, Investigation, Project administration, Validation, Editing, Review","Visualization, Validation, Writing – review and editing"]},{"key":"dc:creator","label":"Author","values":["Fatema, Kaniz","Mohammed, Dr. Emad","Sehra, Dr. Sukhjit Singh"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date","label":"Dc Date","values":["2026-01-01T08:00:00Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-04-20T07:00:00Z"]},{"key":"dc:publisher","label":"Institution","values":["Wilfrid Laurier University"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Physics and Computer Science"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Applied Computing"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Wilfrid Laurier University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Kolmogorov–Arnold Network (KAN)","Taylor Series Approximation","TaylorKAN-ViT","Transformer Model","Small dataset","parameter efficiency.","Engineering","Life Sciences","Medicine and Health Sciences"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["2 Publicly accessible"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://scholars.wlu.ca/etd/2901","https://scholars.wlu.ca/context/etd/article/4064/viewcontent/Kaniz_Fatema_TaylorKAN_ViT_Final.pdf"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description","label":"Description","values":["Effective and interpretable classification of medical images remains a critical challenge in computer-aided diagnosis, particularly in data-scarce and resource-constrained clinical settings where traditional deep learning models prove impractical. This study addresses the fundamental barrier to Vision Transformer adoption in medical imaging—massive parameter counts and data requirements—through a systematic two-phase methodology. Phase 1 evaluates three spline-based Kolmogorov–Arnold Network (KAN) variants to identify the optimal nonlinear approximation function for parameter-efficient medical image classification: SBTAYLOR-KAN (B-splines with Taylor series), SBRBF-KAN (B-splines with Radial Basis Functions), and SBWAVELET-KAN (B-splines with Morlet wavelets). Comprehensive experiments across brain MRI, chest X-rays, and tuberculosis datasets—without any image preprocessing beyond the datasets' original published forms—establish SBTAYLOR-KAN as the superior architecture, achieving up to 98.93% accuracy with only 2,872 parameters (>99% reduction versus ResNet50's ~24.18M) while maintaining 86% accuracy using merely 30% training data. Statistical validation through kappa coefficients, Matthews correlation, and cross-dataset generalization confirms its robustness and data efficiency. Building directly on these findings, Phase 2 integrates the optimal Taylor-KAN formulation into a Vision Transformer architecture, yielding TaylorKAN-ViT—an ultra-compact model that fundamentally reimagines efficient transformer design through a KAN-first approach. Unlike conventional ViTs that retrofit parameter reduction techniques while retaining MLP-heavy architectures, TaylorKAN-ViT replaces all nonlinear feed-forward mappings with the Taylor-series-approximated KAN modules identified in Phase 1. This enables dual-scale feature learning: KAN transformations capture fine-grained local patterns within image patches, while self-attention mechanisms model long-range global dependencies across the entire image. Despite comprising only 88.9K parameters and 4.9G FLOPs—representing ~99.3% parameter reduction compared to recent medical ViTs (MedKAFormer-T: 12.47M, MedViTV2-T: 12.3M)—TaylorKAN-ViT achieves competitive performance across four diverse benchmarks: 94.36% accuracy on PneumoniaMNIST, 95.90% on CPNX-ray, 61.00% on PAD-UFES-20, and 70.50% on Kvasir. The model demonstrates stable generalization even under limited-data and class-imbalanced conditions. These results demonstrate that clinical-grade medical image classification is achievable without large-scale models, establishing TaylorKAN-ViT as a practical, deployable solution for edge devices, mobile platforms, and resource-limited healthcare environments."]},{"key":"dc:format","label":"Dc Format","values":["application/pdf"]},{"key":"dc:title","label":"Title","values":["TaylorKAN-ViT: Parameter-Efficient Vision Transformers for Medical Image Classification"]}]}],"canonical_facts":{"dc:contributor":["Dr. Emad Mohammed","Dr. Sukhjit Singh Sehra"],"dc:contributor.role":["Supervision, Formal analysis, Investigation, Project administration, Validation, Editing, Review","Visualization, Validation, Writing – review and editing"],"dc:creator":["Fatema, Kaniz","Mohammed, Dr. Emad","Sehra, Dr. Sukhjit Singh"],"dc:date":["2026-01-01T08:00:00Z"],"dc:date.available":["2026-04-20T07:00:00Z"],"dc:description":["Effective and interpretable classification of medical images remains a critical challenge in computer-aided diagnosis, particularly in data-scarce and resource-constrained clinical settings where traditional deep learning models prove impractical. This study addresses the fundamental barrier to Vision Transformer adoption in medical imaging—massive parameter counts and data requirements—through a systematic two-phase methodology. Phase 1 evaluates three spline-based Kolmogorov–Arnold Network (KAN) variants to identify the optimal nonlinear approximation function for parameter-efficient medical image classification: SBTAYLOR-KAN (B-splines with Taylor series), SBRBF-KAN (B-splines with Radial Basis Functions), and SBWAVELET-KAN (B-splines with Morlet wavelets). Comprehensive experiments across brain MRI, chest X-rays, and tuberculosis datasets—without any image preprocessing beyond the datasets' original published forms—establish SBTAYLOR-KAN as the superior architecture, achieving up to 98.93% accuracy with only 2,872 parameters (>99% reduction versus ResNet50's ~24.18M) while maintaining 86% accuracy using merely 30% training data. Statistical validation through kappa coefficients, Matthews correlation, and cross-dataset generalization confirms its robustness and data efficiency. Building directly on these findings, Phase 2 integrates the optimal Taylor-KAN formulation into a Vision Transformer architecture, yielding TaylorKAN-ViT—an ultra-compact model that fundamentally reimagines efficient transformer design through a KAN-first approach. Unlike conventional ViTs that retrofit parameter reduction techniques while retaining MLP-heavy architectures, TaylorKAN-ViT replaces all nonlinear feed-forward mappings with the Taylor-series-approximated KAN modules identified in Phase 1. This enables dual-scale feature learning: KAN transformations capture fine-grained local patterns within image patches, while self-attention mechanisms model long-range global dependencies across the entire image. Despite comprising only 88.9K parameters and 4.9G FLOPs—representing ~99.3% parameter reduction compared to recent medical ViTs (MedKAFormer-T: 12.47M, MedViTV2-T: 12.3M)—TaylorKAN-ViT achieves competitive performance across four diverse benchmarks: 94.36% accuracy on PneumoniaMNIST, 95.90% on CPNX-ray, 61.00% on PAD-UFES-20, and 70.50% on Kvasir. The model demonstrates stable generalization even under limited-data and class-imbalanced conditions. These results demonstrate that clinical-grade medical image classification is achievable without large-scale models, establishing TaylorKAN-ViT as a practical, deployable solution for edge devices, mobile platforms, and resource-limited healthcare environments."],"dc:format":["application/pdf"],"dc:identifier":["https://scholars.wlu.ca/etd/2901","https://scholars.wlu.ca/context/etd/article/4064/viewcontent/Kaniz_Fatema_TaylorKAN_ViT_Final.pdf"],"dc:language":["en"],"dc:publisher":["Wilfrid Laurier University"],"dc:rights":["2 Publicly accessible"],"dc:subject":["Kolmogorov–Arnold Network (KAN)","Taylor Series Approximation","TaylorKAN-ViT","Transformer Model","Small dataset","parameter efficiency.","Engineering","Life Sciences","Medicine and Health Sciences"],"dc:title":["TaylorKAN-ViT: Parameter-Efficient Vision Transformers for Medical Image Classification"],"dc:type":["Thesis"],"thesis:degree_discipline":["Physics and Computer Science"],"thesis:degree_name":["Master of Applied Computing"],"thesis:institution_name":["Wilfrid Laurier University"]},"updated_at":"2026-11-18T22:09:03Z"}