{"id":{"repo_id":"wustl","oai_identifier":"oai:repository.library.washu.edu:etd-1252"},"canonical_url":"https://search.ndltd.org/etd/wustl/oai:repository.library.washu.edu:etd-1252","repository":{"repo_id":"wustl","name":"Washington University in St. Louis","base_url":"https://openscholarship.wustl.edu/do/oai/"},"display":{"title":"Optical Measurements in Gas-Liquid Stirred Tanks","abstract":"This dissertation outlines the development of novel, in-situ and relatively inexpensive optical measurement techniques for use in opaque multiphase reactors at elevated temperature: 350 ┬░C) and pressure: 180 bar) environments where conventional measurement techniques either cannot be used or are difficult or expensive to implement. Important parameters: such as gas holdup, specific interfacial area, bubble velocity, bubble chord lengths, liquid level, and phase transition) in opaque, multiphase reactors at industrially relevant conditions are lacking in the literature. A miniaturized 4-point probe is developed and methodology outlined that can simultaneously capture local gas holdup, interfacial area, size, and velocities of bubbles in a multiphase stirred tank reactor where small bubble sizes can be expected, especially at elevated pressures and/or high agitation rates. The miniaturized 4-point probe accurately captures bubble dynamics of bubbles as small as 850 microns at elevated temperature and pressure. Single-point probes are also developed that are moveable under high pressure that can measure liquid level in a reactor as well as the volumetric expansion of carbon dioxide expanded liquids: CXLs are an emerging green technology). A reflectance-based probe: a 7-fiber, hexagonally packed bundle) that detects critical opalescence and thus the phase transition of complex, multicomponent systems from the subcritical to the supercritical state is also developed for the investigation of CXLs. Most importantly, detailed instructions for construction of all of the above optical probe technologies are provided in a step-by-step manner.","abstract_html":"This dissertation outlines the development of novel, in-situ and relatively inexpensive optical measurement techniques for use in opaque multiphase reactors at elevated temperature: 350 ┬░C) and pressure: 180 bar) environments where conventional measurement techniques either cannot be used or are difficult or expensive to implement. Important parameters: such as gas holdup, specific interfacial area, bubble velocity, bubble chord lengths, liquid level, and phase transition) in opaque, multiphase reactors at industrially relevant conditions are lacking in the literature. A miniaturized 4-point probe is developed and methodology outlined that can simultaneously capture local gas holdup, interfacial area, size, and velocities of bubbles in a multiphase stirred tank reactor where small bubble sizes can be expected, especially at elevated pressures and/or high agitation rates. The miniaturized 4-point probe accurately captures bubble dynamics of bubbles as small as 850 microns at elevated temperature and pressure. Single-point probes are also developed that are moveable under high pressure that can measure liquid level in a reactor as well as the volumetric expansion of carbon dioxide expanded liquids: CXLs are an emerging green technology). A reflectance-based probe: a 7-fiber, hexagonally packed bundle) that detects critical opalescence and thus the phase transition of complex, multicomponent systems from the subcritical to the supercritical state is also developed for the investigation of CXLs. Most importantly, detailed instructions for construction of all of the above optical probe technologies are provided in a step-by-step manner.","abstract_has_math":false,"creators":["Mueller, Sean"],"institution":null,"degree_name":"Doctor of Philosophy (PhD)","degree_level":"Dissertation","degree_discipline":"Energy, Environmental and Chemical Engineering","degree_department":null,"school":null,"contributors":["Milorad Dudukovic"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-27T07:23:07Z","subjects":["Engineering","Chemical","General","bubble","gas liquid","optical","probe","reactor","stirred tank"],"languages":["English (en)"],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.library.washu.edu/etd/253"],"render_values":[{"text":"https://repository.library.washu.edu/etd/253","href":"https://repository.library.washu.edu/etd/253","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.7936/K7833Q3X","outbound_label":"DOI","outbound_source":"dc:identifier.doi","record_url":"https://doi.org/10.7936/K7833Q3X","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier.doi","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Awustl%3Aoai%3Arepository.library.washu.edu%3Aetd-1252","prefix":"oai_dc"},"source_record":{"url":"https://openscholarship.wustl.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Arepository.library.washu.edu%3Aetd-1252","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Milorad Dudukovic"]},{"key":"dc:creator","label":"Author","values":["Mueller, Sean"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2010-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2009-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Energy, Environmental and Chemical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Doctor of Philosophy (PhD)"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Engineering","Chemical","General","bubble","gas liquid","optical","probe","reactor","stirred tank"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["English (en)"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://repository.library.washu.edu/etd/253"]},{"key":"dc:identifier.doi","label":"DOI","values":["https://doi.org/10.7936/K7833Q3X"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This dissertation outlines the development of novel, in-situ and relatively inexpensive optical measurement techniques for use in opaque multiphase reactors at elevated temperature: 350 ┬░C) and pressure: 180 bar) environments where conventional measurement techniques either cannot be used or are difficult or expensive to implement. Important parameters: such as gas holdup, specific interfacial area, bubble velocity, bubble chord lengths, liquid level, and phase transition) in opaque, multiphase reactors at industrially relevant conditions are lacking in the literature. A miniaturized 4-point probe is developed and methodology outlined that can simultaneously capture local gas holdup, interfacial area, size, and velocities of bubbles in a multiphase stirred tank reactor where small bubble sizes can be expected, especially at elevated pressures and/or high agitation rates. The miniaturized 4-point probe accurately captures bubble dynamics of bubbles as small as 850 microns at elevated temperature and pressure. Single-point probes are also developed that are moveable under high pressure that can measure liquid level in a reactor as well as the volumetric expansion of carbon dioxide expanded liquids: CXLs are an emerging green technology). A reflectance-based probe: a 7-fiber, hexagonally packed bundle) that detects critical opalescence and thus the phase transition of complex, multicomponent systems from the subcritical to the supercritical state is also developed for the investigation of CXLs. Most importantly, detailed instructions for construction of all of the above optical probe technologies are provided in a step-by-step manner."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>Permanent URL: http://dx.doi.org/10.7936/K7833Q3X"]},{"key":"dc:title","label":"Title","values":["Optical Measurements in Gas-Liquid Stirred Tanks"]}]}],"canonical_facts":{"dc:contributor":["Milorad Dudukovic"],"dc:creator":["Mueller, Sean"],"dc:date.available":["2010-01-01T08:00:00Z"],"dc:date.created":["2009-01-01T08:00:00Z"],"dc:description.abstract":["This dissertation outlines the development of novel, in-situ and relatively inexpensive optical measurement techniques for use in opaque multiphase reactors at elevated temperature: 350 ┬░C) and pressure: 180 bar) environments where conventional measurement techniques either cannot be used or are difficult or expensive to implement. Important parameters: such as gas holdup, specific interfacial area, bubble velocity, bubble chord lengths, liquid level, and phase transition) in opaque, multiphase reactors at industrially relevant conditions are lacking in the literature. A miniaturized 4-point probe is developed and methodology outlined that can simultaneously capture local gas holdup, interfacial area, size, and velocities of bubbles in a multiphase stirred tank reactor where small bubble sizes can be expected, especially at elevated pressures and/or high agitation rates. The miniaturized 4-point probe accurately captures bubble dynamics of bubbles as small as 850 microns at elevated temperature and pressure. Single-point probes are also developed that are moveable under high pressure that can measure liquid level in a reactor as well as the volumetric expansion of carbon dioxide expanded liquids: CXLs are an emerging green technology). A reflectance-based probe: a 7-fiber, hexagonally packed bundle) that detects critical opalescence and thus the phase transition of complex, multicomponent systems from the subcritical to the supercritical state is also developed for the investigation of CXLs. Most importantly, detailed instructions for construction of all of the above optical probe technologies are provided in a step-by-step manner."],"dc:description.note":["<p>Permanent URL: http://dx.doi.org/10.7936/K7833Q3X"],"dc:identifier":["https://repository.library.washu.edu/etd/253"],"dc:identifier.doi":["https://doi.org/10.7936/K7833Q3X"],"dc:language":["English (en)"],"dc:subject":["Engineering","Chemical","General","bubble","gas liquid","optical","probe","reactor","stirred tank"],"dc:title":["Optical Measurements in Gas-Liquid Stirred Tanks"],"thesis:degree_discipline":["Energy, Environmental and Chemical Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["Doctor of Philosophy (PhD)"]},"updated_at":"2026-11-27T07:23:07Z"}