{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-11532"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-11532","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"The connection between the current penetration-based national ambient air quality standard and dose can be considered questionable.","abstract":"This research examined the bias between penetration (as PM2.5) and deposition (as deposited submicrometer particulate DSP) due to the variability of ambient air particle size distributions. A size mobility particle analyzer and portable dust monitor were used to measure count and mass data at three locations in Morgantown West Virginia It was found that over 50% of the median diameters are less than 1µm. A correlation between deposition and penetration was found even though the PM 2.5 criterion is not a good indication of dose. This was due to a lack of variability in the measured distributions. Further research is needed to determine if this finding is supportable over longer time periods and larger areas.","abstract_html":"This research examined the bias between penetration (as PM2.5) and deposition (as deposited submicrometer particulate DSP) due to the variability of ambient air particle size distributions. A size mobility particle analyzer and portable dust monitor were used to measure count and mass data at three locations in Morgantown West Virginia It was found that over 50% of the median diameters are less than 1µm. A correlation between deposition and penetration was found even though the PM 2.5 criterion is not a good indication of dose. This was due to a lack of variability in the measured distributions. Further research is needed to determine if this finding is supportable over longer time periods and larger areas.","abstract_has_math":false,"creators":["Berakis, Michael T."],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Dianne L. McMullin","Michael A. McCawley","Ralph W. Plummer"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:19:47Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/10430"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/10430","href":"https://researchrepository.wvu.edu/etd/10430","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.10430","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.10430","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-11532","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Dianne L. McMullin","Michael A. McCawley","Ralph W. Plummer"]},{"key":"dc:creator","label":"Author","values":["Berakis, Michael T."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["1999-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.10430","https://researchrepository.wvu.edu/etd/10430"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This research examined the bias between penetration (as PM2.5) and deposition (as deposited submicrometer particulate DSP) due to the variability of ambient air particle size distributions. A size mobility particle analyzer and portable dust monitor were used to measure count and mass data at three locations in Morgantown West Virginia It was found that over 50% of the median diameters are less than 1µm. A correlation between deposition and penetration was found even though the PM 2.5 criterion is not a good indication of dose. This was due to a lack of variability in the measured distributions. Further research is needed to determine if this finding is supportable over longer time periods and larger areas."]},{"key":"dc:title","label":"Title","values":["The connection between the current penetration-based national ambient air quality standard and dose can be considered questionable."]}]}],"canonical_facts":{"dc:contributor":["Dianne L. McMullin","Michael A. McCawley","Ralph W. Plummer"],"dc:creator":["Berakis, Michael T."],"dc:date.available":["2023-02-17T08:00:00Z"],"dc:date.created":["1999-01-01T08:00:00Z"],"dc:description.abstract":["This research examined the bias between penetration (as PM2.5) and deposition (as deposited submicrometer particulate DSP) due to the variability of ambient air particle size distributions. A size mobility particle analyzer and portable dust monitor were used to measure count and mass data at three locations in Morgantown West Virginia It was found that over 50% of the median diameters are less than 1µm. A correlation between deposition and penetration was found even though the PM 2.5 criterion is not a good indication of dose. This was due to a lack of variability in the measured distributions. Further research is needed to determine if this finding is supportable over longer time periods and larger areas."],"dc:identifier":["https://doi.org/10.33915/etd.10430","https://researchrepository.wvu.edu/etd/10430"],"dc:title":["The connection between the current penetration-based national ambient air quality standard and dose can be considered questionable."],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:19:47Z"}