{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-11660"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-11660","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Processing improvement of MoirÃ© interferometry for accurate crack-tip deformation measurement.","abstract":"Recent research advancement of moiré interferometry has incorporated phase shifting, a technique for better accuracy and easier digital image processing. However, moiré interferometry with phase shifting also revealed some sensitivity problems. Background noise associated with the topography of the specimen and optical effect produces rough and discontinuous displacement fields, which makes it difficult to obtain accurate strains and stresses. In this research, two alternate methods that improve the sensitivity of moiré interferometry, with and without phase shifting is developed. The result is a smoother displacement fields with higher sensitivity at the crack tip area. A single edge notched bend specimen was used in the experiment and the result was compared to numerical analysis using the finite element software package ABAQUS TM. The comparison of the crack-tip principal and effective strains between the two alternate methods and finite element shows good agreement. Sensitivity at the crack tip area was higher compared to result from moiré interferometry with phase shifting. The two alternate methods were proven to be better than moiré interferometry with phase shifting alone.","abstract_html":"Recent research advancement of moiré interferometry has incorporated phase shifting, a technique for better accuracy and easier digital image processing. However, moiré interferometry with phase shifting also revealed some sensitivity problems. Background noise associated with the topography of the specimen and optical effect produces rough and discontinuous displacement fields, which makes it difficult to obtain accurate strains and stresses. In this research, two alternate methods that improve the sensitivity of moiré interferometry, with and without phase shifting is developed. The result is a smoother displacement fields with higher sensitivity at the crack tip area. A single edge notched bend specimen was used in the experiment and the result was compared to numerical analysis using the finite element software package ABAQUS TM. The comparison of the crack-tip principal and effective strains between the two alternate methods and finite element shows good agreement. Sensitivity at the crack tip area was higher compared to result from moiré interferometry with phase shifting. The two alternate methods were proven to be better than moiré interferometry with phase shifting alone.","abstract_has_math":false,"creators":["Kamil, Ridha"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Bruce Kang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:12:54Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/10558"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/10558","href":"https://researchrepository.wvu.edu/etd/10558","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.10558","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.10558","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-11660","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Bruce Kang"]},{"key":"dc:creator","label":"Author","values":["Kamil, Ridha"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2001-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.10558","https://researchrepository.wvu.edu/etd/10558"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Recent research advancement of moiré interferometry has incorporated phase shifting, a technique for better accuracy and easier digital image processing. However, moiré interferometry with phase shifting also revealed some sensitivity problems. Background noise associated with the topography of the specimen and optical effect produces rough and discontinuous displacement fields, which makes it difficult to obtain accurate strains and stresses. In this research, two alternate methods that improve the sensitivity of moiré interferometry, with and without phase shifting is developed. The result is a smoother displacement fields with higher sensitivity at the crack tip area. A single edge notched bend specimen was used in the experiment and the result was compared to numerical analysis using the finite element software package ABAQUS TM. The comparison of the crack-tip principal and effective strains between the two alternate methods and finite element shows good agreement. Sensitivity at the crack tip area was higher compared to result from moiré interferometry with phase shifting. The two alternate methods were proven to be better than moiré interferometry with phase shifting alone."]},{"key":"dc:title","label":"Title","values":["Processing improvement of MoirÃ© interferometry for accurate crack-tip deformation measurement."]}]}],"canonical_facts":{"dc:contributor":["Bruce Kang"],"dc:creator":["Kamil, Ridha"],"dc:date.available":["2023-02-17T08:00:00Z"],"dc:date.created":["2001-01-01T08:00:00Z"],"dc:description.abstract":["Recent research advancement of moiré interferometry has incorporated phase shifting, a technique for better accuracy and easier digital image processing. However, moiré interferometry with phase shifting also revealed some sensitivity problems. Background noise associated with the topography of the specimen and optical effect produces rough and discontinuous displacement fields, which makes it difficult to obtain accurate strains and stresses. In this research, two alternate methods that improve the sensitivity of moiré interferometry, with and without phase shifting is developed. The result is a smoother displacement fields with higher sensitivity at the crack tip area. A single edge notched bend specimen was used in the experiment and the result was compared to numerical analysis using the finite element software package ABAQUS TM. The comparison of the crack-tip principal and effective strains between the two alternate methods and finite element shows good agreement. Sensitivity at the crack tip area was higher compared to result from moiré interferometry with phase shifting. The two alternate methods were proven to be better than moiré interferometry with phase shifting alone."],"dc:identifier":["https://doi.org/10.33915/etd.10558","https://researchrepository.wvu.edu/etd/10558"],"dc:title":["Processing improvement of MoirÃ© interferometry for accurate crack-tip deformation measurement."],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:12:54Z"}