{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-11767"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-11767","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis.","abstract":"There are two classifications of femoral implants ñ cemented and cementless. The object of this study was to assess the effect of bone viscoelasticity on cemented and cementless implant stability. A cemented implant design was evaluated via a 3-D FE model. The results showed a small 1.41% increase in stem subsidence with inclusion of bone viscoelasticity. This is explained by the low stresses at the cement-bone interface. A 2-D FE model was utilized to evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ > 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% to 82.6%) in all cases. It is concluded that there is a ìthresholdî with respect to the degree of press-fit beyond which no additional gains in fixation are achieved.","abstract_html":"There are two classifications of femoral implants ñ cemented and cementless. The object of this study was to assess the effect of bone viscoelasticity on cemented and cementless implant stability. A cemented implant design was evaluated via a 3-D FE model. The results showed a small 1.41% increase in stem subsidence with inclusion of bone viscoelasticity. This is explained by the low stresses at the cement-bone interface. A 2-D FE model was utilized to evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ &gt; 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% to 82.6%) in all cases. It is concluded that there is a ìthresholdî with respect to the degree of press-fit beyond which no additional gains in fixation are achieved.","abstract_has_math":false,"creators":["Shultz, Travis Ray"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Timothy L. Norman"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:13:02Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/10665"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/10665","href":"https://researchrepository.wvu.edu/etd/10665","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.10665","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.10665","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-11767","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Timothy L. Norman"]},{"key":"dc:creator","label":"Author","values":["Shultz, Travis Ray"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-02-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2002-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.10665","https://researchrepository.wvu.edu/etd/10665"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There are two classifications of femoral implants ñ cemented and cementless. The object of this study was to assess the effect of bone viscoelasticity on cemented and cementless implant stability. A cemented implant design was evaluated via a 3-D FE model. The results showed a small 1.41% increase in stem subsidence with inclusion of bone viscoelasticity. This is explained by the low stresses at the cement-bone interface. A 2-D FE model was utilized to evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ > 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% to 82.6%) in all cases. It is concluded that there is a ìthresholdî with respect to the degree of press-fit beyond which no additional gains in fixation are achieved."]},{"key":"dc:title","label":"Title","values":["The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis."]}]}],"canonical_facts":{"dc:contributor":["Timothy L. Norman"],"dc:creator":["Shultz, Travis Ray"],"dc:date.available":["2023-02-17T08:00:00Z"],"dc:date.created":["2002-01-01T08:00:00Z"],"dc:description.abstract":["There are two classifications of femoral implants ñ cemented and cementless. The object of this study was to assess the effect of bone viscoelasticity on cemented and cementless implant stability. A cemented implant design was evaluated via a 3-D FE model. The results showed a small 1.41% increase in stem subsidence with inclusion of bone viscoelasticity. This is explained by the low stresses at the cement-bone interface. A 2-D FE model was utilized to evaluate the effects of coefficient of friction, press-fit and bone viscoelasticity on stem fixation. The push-out load increased with µ for each value of δ, but minimal increases in the push-out load (2.9% to 4.9%) were observed for δ > 0.10mm. Bone viscoelasticity reduced the push-out load (2.6% to 82.6%) in all cases. It is concluded that there is a ìthresholdî with respect to the degree of press-fit beyond which no additional gains in fixation are achieved."],"dc:identifier":["https://doi.org/10.33915/etd.10665","https://researchrepository.wvu.edu/etd/10665"],"dc:title":["The effects of cortical bone viscoelasticity on the fixation/stability of cemented and cementless femoral implants: A finite element analysis."],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:13:02Z"}