{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-12486"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-12486","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Performance of Peltier Cooled Technology During Preconcentration of Volatile Organic Compounds Analyzed by Gas Chromatography-Mass Spectrometry (GC-MS) using NIOSH Manual of Analytical Methods (NMAM) 3900","abstract":"Using evacuated canisters for whole-air sampling allows for sampling without specific knowledge of the environment and potential analytes. Evacuated canisters are able to tolerate concentrations ranging from parts per trillion (PPT) to parts per million (PPM). The U.S. Environmental Protection Agency (EPA) has used evacuated canisters for years to sample volatile organic compounds (VOCs) from ambient air using their method TO-15 (LeBouf, et al., 2019). The GC-MS system used for the development of NMAM 3900 used liquid nitrogen to cool sorbent traps in the preconcentrator. Liquid nitrogen allows for cooling of specified points below ambient temperature. An alternative to liquid nitrogen for cooling is Peltier cooled technology. Advantages of using Peltier cooled technology include cost saving as well as extended run times with continuous operation because it does not need to have a continuous supply of liquid nitrogen to cool the system. This research assessed the use of systems equipped with Peltier cooled technology for NMAM 3900. Parts per billion and parts per million levels were evaluated on the Peltier system for 20 volatile organic compounds. To determine the performance of the system for the compounds, bias, precision, and accuracy were calculated for each targeted analyte. At the PPB concentration level, a total of 15 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed the NIOSH accuracy criterion (± 25% error). At the PPM concentration level, a total of 16 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, acetonitrile, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed for this criterion. At both PPB and PPM levels, acetaldehyde, acetone, ethanol, and isopropyl alcohol failed to pass the NIOSH accuracy criterion. Polar compounds did not perform well on this system due to the water management system. Overall, this method performs well for the compounds which passed and is beneficial to individuals looking to sample for these compounds and avoid the additional cost of using liquid nitrogen preconcentration.","abstract_html":"Using evacuated canisters for whole-air sampling allows for sampling without specific knowledge of the environment and potential analytes. Evacuated canisters are able to tolerate concentrations ranging from parts per trillion (PPT) to parts per million (PPM). The U.S. Environmental Protection Agency (EPA) has used evacuated canisters for years to sample volatile organic compounds (VOCs) from ambient air using their method TO-15 (LeBouf, et al., 2019). The GC-MS system used for the development of NMAM 3900 used liquid nitrogen to cool sorbent traps in the preconcentrator. Liquid nitrogen allows for cooling of specified points below ambient temperature. An alternative to liquid nitrogen for cooling is Peltier cooled technology. Advantages of using Peltier cooled technology include cost saving as well as extended run times with continuous operation because it does not need to have a continuous supply of liquid nitrogen to cool the system. This research assessed the use of systems equipped with Peltier cooled technology for NMAM 3900. Parts per billion and parts per million levels were evaluated on the Peltier system for 20 volatile organic compounds. To determine the performance of the system for the compounds, bias, precision, and accuracy were calculated for each targeted analyte. At the PPB concentration level, a total of 15 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed the NIOSH accuracy criterion (± 25% error). At the PPM concentration level, a total of 16 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, acetonitrile, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed for this criterion. At both PPB and PPM levels, acetaldehyde, acetone, ethanol, and isopropyl alcohol failed to pass the NIOSH accuracy criterion. Polar compounds did not perform well on this system due to the water management system. Overall, this method performs well for the compounds which passed and is beneficial to individuals looking to sample for these compounds and avoid the additional cost of using liquid nitrogen preconcentration.","abstract_has_math":false,"creators":["Fernandez, Elizabeth Ann"],"institution":null,"degree_name":"PhD","degree_level":"Dissertation","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":["Jeremy Gouzd","Gary L. Winn","Travis Knuckles","Omar Al-Shebeeb","David Wyrick"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:20:09Z","subjects":["Industrial Hygiene","Gas Chromatography","Mass Spectrometry","Volatile Organic Compounds (VOCs)","Whole-air Sampling","Environmental Public Health","Occupational Health and Industrial Hygiene","Other Public Health"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0000-0002-6654-2166\">https://orcid.org/0000-0002-6654-2166</a></p>","https://researchrepository.wvu.edu/etd/11454"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0000-0002-6654-2166\">https://orcid.org/0000-0002-6654-2166</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/11454","href":"https://researchrepository.wvu.edu/etd/11454","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.11454","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.11454","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-12486","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jeremy Gouzd","Gary L. Winn","Travis Knuckles","Omar Al-Shebeeb","David Wyrick"]},{"key":"dc:creator","label":"Author","values":["Fernandez, Elizabeth Ann"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2025-12-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2022-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Industrial Hygiene","Gas Chromatography","Mass Spectrometry","Volatile Organic Compounds (VOCs)","Whole-air Sampling","Environmental Public Health","Occupational Health and Industrial Hygiene","Other Public Health"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0000-0002-6654-2166\">https://orcid.org/0000-0002-6654-2166</a></p>","https://doi.org/10.33915/etd.11454","https://researchrepository.wvu.edu/etd/11454"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Using evacuated canisters for whole-air sampling allows for sampling without specific knowledge of the environment and potential analytes. Evacuated canisters are able to tolerate concentrations ranging from parts per trillion (PPT) to parts per million (PPM). The U.S. Environmental Protection Agency (EPA) has used evacuated canisters for years to sample volatile organic compounds (VOCs) from ambient air using their method TO-15 (LeBouf, et al., 2019). The GC-MS system used for the development of NMAM 3900 used liquid nitrogen to cool sorbent traps in the preconcentrator. Liquid nitrogen allows for cooling of specified points below ambient temperature. An alternative to liquid nitrogen for cooling is Peltier cooled technology. Advantages of using Peltier cooled technology include cost saving as well as extended run times with continuous operation because it does not need to have a continuous supply of liquid nitrogen to cool the system. This research assessed the use of systems equipped with Peltier cooled technology for NMAM 3900. Parts per billion and parts per million levels were evaluated on the Peltier system for 20 volatile organic compounds. To determine the performance of the system for the compounds, bias, precision, and accuracy were calculated for each targeted analyte. At the PPB concentration level, a total of 15 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed the NIOSH accuracy criterion (± 25% error). At the PPM concentration level, a total of 16 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, acetonitrile, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed for this criterion. At both PPB and PPM levels, acetaldehyde, acetone, ethanol, and isopropyl alcohol failed to pass the NIOSH accuracy criterion. Polar compounds did not perform well on this system due to the water management system. Overall, this method performs well for the compounds which passed and is beneficial to individuals looking to sample for these compounds and avoid the additional cost of using liquid nitrogen preconcentration."]},{"key":"dc:title","label":"Title","values":["Performance of Peltier Cooled Technology During Preconcentration of Volatile Organic Compounds Analyzed by Gas Chromatography-Mass Spectrometry (GC-MS) using NIOSH Manual of Analytical Methods (NMAM) 3900"]}]}],"canonical_facts":{"dc:contributor":["Jeremy Gouzd","Gary L. Winn","Travis Knuckles","Omar Al-Shebeeb","David Wyrick"],"dc:creator":["Fernandez, Elizabeth Ann"],"dc:date.available":["2025-12-09T08:00:00Z"],"dc:date.created":["2022-01-01T08:00:00Z"],"dc:description.abstract":["Using evacuated canisters for whole-air sampling allows for sampling without specific knowledge of the environment and potential analytes. Evacuated canisters are able to tolerate concentrations ranging from parts per trillion (PPT) to parts per million (PPM). The U.S. Environmental Protection Agency (EPA) has used evacuated canisters for years to sample volatile organic compounds (VOCs) from ambient air using their method TO-15 (LeBouf, et al., 2019). The GC-MS system used for the development of NMAM 3900 used liquid nitrogen to cool sorbent traps in the preconcentrator. Liquid nitrogen allows for cooling of specified points below ambient temperature. An alternative to liquid nitrogen for cooling is Peltier cooled technology. Advantages of using Peltier cooled technology include cost saving as well as extended run times with continuous operation because it does not need to have a continuous supply of liquid nitrogen to cool the system. This research assessed the use of systems equipped with Peltier cooled technology for NMAM 3900. Parts per billion and parts per million levels were evaluated on the Peltier system for 20 volatile organic compounds. To determine the performance of the system for the compounds, bias, precision, and accuracy were calculated for each targeted analyte. At the PPB concentration level, a total of 15 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed the NIOSH accuracy criterion (± 25% error). At the PPM concentration level, a total of 16 compounds (2,3-butanedione, 2,3-hexandione, 2,3-pentanedione, acetonitrile, α-pinene, benzene, chloroform, d-limonene, ethylbenzene, m,p-xylene, methyl methacrylate, methylene chloride, n-hexane, o-xylene, styrene, toluene) passed for this criterion. At both PPB and PPM levels, acetaldehyde, acetone, ethanol, and isopropyl alcohol failed to pass the NIOSH accuracy criterion. Polar compounds did not perform well on this system due to the water management system. Overall, this method performs well for the compounds which passed and is beneficial to individuals looking to sample for these compounds and avoid the additional cost of using liquid nitrogen preconcentration."],"dc:identifier":["<p><a href=\"https://orcid.org/0000-0002-6654-2166\">https://orcid.org/0000-0002-6654-2166</a></p>","https://doi.org/10.33915/etd.11454","https://researchrepository.wvu.edu/etd/11454"],"dc:subject":["Industrial Hygiene","Gas Chromatography","Mass Spectrometry","Volatile Organic Compounds (VOCs)","Whole-air Sampling","Environmental Public Health","Occupational Health and Industrial Hygiene","Other Public Health"],"dc:title":["Performance of Peltier Cooled Technology During Preconcentration of Volatile Organic Compounds Analyzed by Gas Chromatography-Mass Spectrometry (GC-MS) using NIOSH Manual of Analytical Methods (NMAM) 3900"],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T09:20:09Z"}