{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-12504"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-12504","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS","abstract":"Introduction: Researchers have compared the differences between hand compaction of root-end filling bioceramics with compaction of these materials by hand followed by ultrasonic activation (hand/ultrasonic compaction). Additionally, most of these researchers did not utilize Micro-Computed Tomography (Micro-CT) analysis. The purpose of this study is to evaluate total porosity volume of three different bioceramics when compacted by hand alone versus hand/ultrasonic compaction using Micro-CT Analysis. Materials and methods: Seventy-two human maxillary central incisors were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection 3-mm from the apex at a 90° to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip. Samples were assigned to six groups (n = 12) according to the root-end filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with Micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results failed to indicate a significant difference between the groups compacted by hand alone and the groups compacted by hand/ultrasonic activation (p= 0.8087). Additionally, each technique among each of the materials failed to show significance, indicating that ultrasonic activation produces similar total porosity volume compared to hand compaction alone. Conclusion: Within the limitations of the present in vitro study, both hand compaction alone and ultrasonic activation resulted in similar total porosity volume.","abstract_html":"Introduction: Researchers have compared the differences between hand compaction of root-end filling bioceramics with compaction of these materials by hand followed by ultrasonic activation (hand/ultrasonic compaction). Additionally, most of these researchers did not utilize Micro-Computed Tomography (Micro-CT) analysis. The purpose of this study is to evaluate total porosity volume of three different bioceramics when compacted by hand alone versus hand/ultrasonic compaction using Micro-CT Analysis. Materials and methods: Seventy-two human maxillary central incisors were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection 3-mm from the apex at a 90° to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip. Samples were assigned to six groups (n = 12) according to the root-end filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with Micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results failed to indicate a significant difference between the groups compacted by hand alone and the groups compacted by hand/ultrasonic activation (p= 0.8087). Additionally, each technique among each of the materials failed to show significance, indicating that ultrasonic activation produces similar total porosity volume compared to hand compaction alone. Conclusion: Within the limitations of the present in vitro study, both hand compaction alone and ultrasonic activation resulted in similar total porosity volume.","abstract_has_math":false,"creators":["Wolford, Leslie P"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":null,"degree_department":null,"school":null,"contributors":["Samuel O. Dorn","R. Constance Wiener","Steven B. Whitaker"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:13:47Z","subjects":[": Dentistry","Endodontics","micro-CT","Bioceramics","Porosity","Filling","Root-end","Sealing.","Endodontics and Endodontology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/11994"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/11994","href":"https://researchrepository.wvu.edu/etd/11994","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.11994","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.11994","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-12504","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Samuel O. Dorn","R. Constance Wiener","Steven B. Whitaker"]},{"key":"dc:creator","label":"Author","values":["Wolford, Leslie P"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2023-03-09T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2023-01-01T08:00:00Z"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":[": Dentistry","Endodontics","micro-CT","Bioceramics","Porosity","Filling","Root-end","Sealing.","Endodontics and Endodontology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.11994","https://researchrepository.wvu.edu/etd/11994"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Introduction: Researchers have compared the differences between hand compaction of root-end filling bioceramics with compaction of these materials by hand followed by ultrasonic activation (hand/ultrasonic compaction). Additionally, most of these researchers did not utilize Micro-Computed Tomography (Micro-CT) analysis. The purpose of this study is to evaluate total porosity volume of three different bioceramics when compacted by hand alone versus hand/ultrasonic compaction using Micro-CT Analysis. Materials and methods: Seventy-two human maxillary central incisors were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection 3-mm from the apex at a 90° to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip. Samples were assigned to six groups (n = 12) according to the root-end filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with Micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results failed to indicate a significant difference between the groups compacted by hand alone and the groups compacted by hand/ultrasonic activation (p= 0.8087). Additionally, each technique among each of the materials failed to show significance, indicating that ultrasonic activation produces similar total porosity volume compared to hand compaction alone. Conclusion: Within the limitations of the present in vitro study, both hand compaction alone and ultrasonic activation resulted in similar total porosity volume."]},{"key":"dc:title","label":"Title","values":["A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS"]}]}],"canonical_facts":{"dc:contributor":["Samuel O. Dorn","R. Constance Wiener","Steven B. Whitaker"],"dc:creator":["Wolford, Leslie P"],"dc:date.available":["2023-03-09T08:00:00Z"],"dc:date.created":["2023-01-01T08:00:00Z"],"dc:description.abstract":["Introduction: Researchers have compared the differences between hand compaction of root-end filling bioceramics with compaction of these materials by hand followed by ultrasonic activation (hand/ultrasonic compaction). Additionally, most of these researchers did not utilize Micro-Computed Tomography (Micro-CT) analysis. The purpose of this study is to evaluate total porosity volume of three different bioceramics when compacted by hand alone versus hand/ultrasonic compaction using Micro-CT Analysis. Materials and methods: Seventy-two human maxillary central incisors were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection 3-mm from the apex at a 90° to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip. Samples were assigned to six groups (n = 12) according to the root-end filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with Micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results failed to indicate a significant difference between the groups compacted by hand alone and the groups compacted by hand/ultrasonic activation (p= 0.8087). Additionally, each technique among each of the materials failed to show significance, indicating that ultrasonic activation produces similar total porosity volume compared to hand compaction alone. Conclusion: Within the limitations of the present in vitro study, both hand compaction alone and ultrasonic activation resulted in similar total porosity volume."],"dc:identifier":["https://doi.org/10.33915/etd.11994","https://researchrepository.wvu.edu/etd/11994"],"dc:subject":[": Dentistry","Endodontics","micro-CT","Bioceramics","Porosity","Filling","Root-end","Sealing.","Endodontics and Endodontology"],"dc:title":["A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:13:47Z"}