{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-13020"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-13020","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Implant Overdenture Abutment Loosening under Hyperbaric Conditions","abstract":"Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments. The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive. Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were placed into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants were divided into three different hyperbaric pressure groups: the control (1 atm), 2.8 atm, and 4 atm. Each pressure group was subdivided into two groups: a one cycle (one scuba dive) group and a six cycles group (equivalent to six separate dives). A total of 6 implants were randomly assigned to each group: 1 atm and one cycle, 1 atm and six cycles, 2.8 atm and one cycle, 2.8 atm and six cycles, 4 atm and one cycle, and 4 atm and six cycles. LOCATOR® loosening was evaluated by obtaining the reverse torque values (RTVs) with a digital torque meter, then subtracting this from the initial tightening torque. The mean loss of torque for all groups were calculated, and a two-way ANOVA test was utilized to complete the statistical analysis. Results: Pressure change was not found to have a statistically significant effect on LOCATOR® loosening (and/or loss of torque). However, the number of cycles did significantly affect the loss of torque, with a confidence of 99%. Conclusions: Based on the statistical analyses, and eventually a two-way ANOVA test, there was no statistically significant effect of pressure on the loss of torque. That is, the LOCATORS® did not loosen more with pressure or loosen less with pressure. Yet, all groups did exhibit torque loss. When it comes to the number of cycles, there was a statistically significant effect between one and six cycles. For the 1 atm pressure, increasing the cycles from 1 to 6 caused a 1.54 field increase in loosening; for the 2.8 atm pressure, increasing the number of cycles caused a 1.38-fold increase in loosening; and, for the 4 atm pressure, increasing the number of cycles caused a 1.67-fold increase in loosening. The LOCATOR® loosening exhibited can be a result of the exposure to pressure. This exposure of pressure involves both the compression and decompression that occur to and from the pressure tested.","abstract_html":"Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments. The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive. Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were placed into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants were divided into three different hyperbaric pressure groups: the control (1 atm), 2.8 atm, and 4 atm. Each pressure group was subdivided into two groups: a one cycle (one scuba dive) group and a six cycles group (equivalent to six separate dives). A total of 6 implants were randomly assigned to each group: 1 atm and one cycle, 1 atm and six cycles, 2.8 atm and one cycle, 2.8 atm and six cycles, 4 atm and one cycle, and 4 atm and six cycles. LOCATOR® loosening was evaluated by obtaining the reverse torque values (RTVs) with a digital torque meter, then subtracting this from the initial tightening torque. The mean loss of torque for all groups were calculated, and a two-way ANOVA test was utilized to complete the statistical analysis. Results: Pressure change was not found to have a statistically significant effect on LOCATOR® loosening (and/or loss of torque). However, the number of cycles did significantly affect the loss of torque, with a confidence of 99%. Conclusions: Based on the statistical analyses, and eventually a two-way ANOVA test, there was no statistically significant effect of pressure on the loss of torque. That is, the LOCATORS® did not loosen more with pressure or loosen less with pressure. Yet, all groups did exhibit torque loss. When it comes to the number of cycles, there was a statistically significant effect between one and six cycles. For the 1 atm pressure, increasing the cycles from 1 to 6 caused a 1.54 field increase in loosening; for the 2.8 atm pressure, increasing the number of cycles caused a 1.38-fold increase in loosening; and, for the 4 atm pressure, increasing the number of cycles caused a 1.67-fold increase in loosening. The LOCATOR® loosening exhibited can be a result of the exposure to pressure. This exposure of pressure involves both the compression and decompression that occur to and from the pressure tested.","abstract_has_math":false,"creators":["Al-Saloum, Zana Jamal"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Restorative Dentistry","degree_department":null,"school":null,"contributors":["Jerry Bouquot","Shelby Alexander","Bryan Weaver"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:20:50Z","subjects":["Scuba Diving","Hyperbaric","locator","LOCATOR®","Overdenture","Boyle's Law","Zimmer TSV","Screw-Loosening","Dental Materials","Other Dentistry","Prosthodontics and Prosthodontology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0001-6208-3564\">https://orcid.org/0009-0001-6208-3564</a></p>","https://researchrepository.wvu.edu/etd/12325"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0009-0001-6208-3564\">https://orcid.org/0009-0001-6208-3564</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/12325","href":"https://researchrepository.wvu.edu/etd/12325","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.12325","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.12325","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-13020","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Jerry Bouquot","Shelby Alexander","Bryan Weaver"]},{"key":"dc:creator","label":"Author","values":["Al-Saloum, Zana Jamal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-05-10T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Restorative Dentistry"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Scuba Diving","Hyperbaric","locator","LOCATOR®","Overdenture","Boyle's Law","Zimmer TSV","Screw-Loosening","Dental Materials","Other Dentistry","Prosthodontics and Prosthodontology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0001-6208-3564\">https://orcid.org/0009-0001-6208-3564</a></p>","https://doi.org/10.33915/etd.12325","https://researchrepository.wvu.edu/etd/12325"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments. The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive. Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were placed into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants were divided into three different hyperbaric pressure groups: the control (1 atm), 2.8 atm, and 4 atm. Each pressure group was subdivided into two groups: a one cycle (one scuba dive) group and a six cycles group (equivalent to six separate dives). A total of 6 implants were randomly assigned to each group: 1 atm and one cycle, 1 atm and six cycles, 2.8 atm and one cycle, 2.8 atm and six cycles, 4 atm and one cycle, and 4 atm and six cycles. LOCATOR® loosening was evaluated by obtaining the reverse torque values (RTVs) with a digital torque meter, then subtracting this from the initial tightening torque. The mean loss of torque for all groups were calculated, and a two-way ANOVA test was utilized to complete the statistical analysis. Results: Pressure change was not found to have a statistically significant effect on LOCATOR® loosening (and/or loss of torque). However, the number of cycles did significantly affect the loss of torque, with a confidence of 99%. Conclusions: Based on the statistical analyses, and eventually a two-way ANOVA test, there was no statistically significant effect of pressure on the loss of torque. That is, the LOCATORS® did not loosen more with pressure or loosen less with pressure. Yet, all groups did exhibit torque loss. When it comes to the number of cycles, there was a statistically significant effect between one and six cycles. For the 1 atm pressure, increasing the cycles from 1 to 6 caused a 1.54 field increase in loosening; for the 2.8 atm pressure, increasing the number of cycles caused a 1.38-fold increase in loosening; and, for the 4 atm pressure, increasing the number of cycles caused a 1.67-fold increase in loosening. The LOCATOR® loosening exhibited can be a result of the exposure to pressure. This exposure of pressure involves both the compression and decompression that occur to and from the pressure tested."]},{"key":"dc:title","label":"Title","values":["Implant Overdenture Abutment Loosening under Hyperbaric Conditions"]}]}],"canonical_facts":{"dc:contributor":["Jerry Bouquot","Shelby Alexander","Bryan Weaver"],"dc:creator":["Al-Saloum, Zana Jamal"],"dc:date.available":["2024-05-10T07:00:00Z"],"dc:date.created":["2024-01-01T08:00:00Z"],"dc:description.abstract":["Objectives: To investigate the effect of various hyperbaric air pressures on the loosening of LOCATOR® (ZEST Anchors, LLC, Escondido, CA USA) overdenture abutments. The pressure conditions tested are meant to simulate scuba diving conditions in edentulous patients that are restored with implant-retained tissue-supported overdentures. Another sub-goal of this study is to determine whether or not there is a difference in LOCATOR® loosening when the sample is exposed to six cycles/dives as opposed to one cycle/dive. Methods: 36 ZimVie Tapered Screw Vent Implants with a 3.5mm diameter implant platform, and a 2.5mm diameter (and 1.5mm deep) internal hexagon were placed into resin blocks. LOCATOR® abutments were torqued to 30 N-cm with a digital torque meter. The implants were divided into three different hyperbaric pressure groups: the control (1 atm), 2.8 atm, and 4 atm. Each pressure group was subdivided into two groups: a one cycle (one scuba dive) group and a six cycles group (equivalent to six separate dives). A total of 6 implants were randomly assigned to each group: 1 atm and one cycle, 1 atm and six cycles, 2.8 atm and one cycle, 2.8 atm and six cycles, 4 atm and one cycle, and 4 atm and six cycles. LOCATOR® loosening was evaluated by obtaining the reverse torque values (RTVs) with a digital torque meter, then subtracting this from the initial tightening torque. The mean loss of torque for all groups were calculated, and a two-way ANOVA test was utilized to complete the statistical analysis. Results: Pressure change was not found to have a statistically significant effect on LOCATOR® loosening (and/or loss of torque). However, the number of cycles did significantly affect the loss of torque, with a confidence of 99%. Conclusions: Based on the statistical analyses, and eventually a two-way ANOVA test, there was no statistically significant effect of pressure on the loss of torque. That is, the LOCATORS® did not loosen more with pressure or loosen less with pressure. Yet, all groups did exhibit torque loss. When it comes to the number of cycles, there was a statistically significant effect between one and six cycles. For the 1 atm pressure, increasing the cycles from 1 to 6 caused a 1.54 field increase in loosening; for the 2.8 atm pressure, increasing the number of cycles caused a 1.38-fold increase in loosening; and, for the 4 atm pressure, increasing the number of cycles caused a 1.67-fold increase in loosening. The LOCATOR® loosening exhibited can be a result of the exposure to pressure. This exposure of pressure involves both the compression and decompression that occur to and from the pressure tested."],"dc:identifier":["<p><a href=\"https://orcid.org/0009-0001-6208-3564\">https://orcid.org/0009-0001-6208-3564</a></p>","https://doi.org/10.33915/etd.12325","https://researchrepository.wvu.edu/etd/12325"],"dc:subject":["Scuba Diving","Hyperbaric","locator","LOCATOR®","Overdenture","Boyle's Law","Zimmer TSV","Screw-Loosening","Dental Materials","Other Dentistry","Prosthodontics and Prosthodontology"],"dc:title":["Implant Overdenture Abutment Loosening under Hyperbaric Conditions"],"thesis:degree_discipline":["Restorative Dentistry"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:20:50Z"}