{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-13130"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-13130","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Evaluation of 50’ FRP Truss Bridges with Timber Decks","abstract":"Fiber-reinforced polymer (FRP) composites have become mainstream structural materials and are being utilized in many different structural applications because of their outstanding thermos-mechanical properties and other characteristics. These characteristics include exceptional corrosion resistance, energy absorption, durability, high strength-to-weight, stiffness-to-weight ratios, and others. Also, FRP composites are cost effective especially when accounting for the service life of such a material. In this study, testing and analysis were performed at both the component as well as a structural system levels. Herein, two FRP truss bridges of different widths with 50 ft. spans underwent extensive testing and analysis in accordance with AASHTO specifications. Data analyzed includes strains, deflections, and frequencies under static and dynamic loads. Individual members were tested to explain how the behavior of a member alone influences the response of a structural system. Structural responses of the two FRP truss bridges under static, vertical, and pseudo-static wind loads were analyzed and reported, and future design recommendations are made. FRP bridge components under axial compression testing exhibited crushing, local buckling, and lateral torsional buckling failures depending on the span to depth ratio of the components and also as a function of stiffness to induced stress ratio. In depth analysis and recommendations are presented pertaining to stress concentrations resulting from the manufacturing process of FRP composite shapes. Strain data of bridge members were analyzed to arrive at factors of safety for different categories of member shapes utilized in the structural systems. Further strain data analysis pertaining to members of a bridge system are related to the response phenomenon occurring in individual component testing.","abstract_html":"Fiber-reinforced polymer (FRP) composites have become mainstream structural materials and are being utilized in many different structural applications because of their outstanding thermos-mechanical properties and other characteristics. These characteristics include exceptional corrosion resistance, energy absorption, durability, high strength-to-weight, stiffness-to-weight ratios, and others. Also, FRP composites are cost effective especially when accounting for the service life of such a material. In this study, testing and analysis were performed at both the component as well as a structural system levels. Herein, two FRP truss bridges of different widths with 50 ft. spans underwent extensive testing and analysis in accordance with AASHTO specifications. Data analyzed includes strains, deflections, and frequencies under static and dynamic loads. Individual members were tested to explain how the behavior of a member alone influences the response of a structural system. Structural responses of the two FRP truss bridges under static, vertical, and pseudo-static wind loads were analyzed and reported, and future design recommendations are made. FRP bridge components under axial compression testing exhibited crushing, local buckling, and lateral torsional buckling failures depending on the span to depth ratio of the components and also as a function of stiffness to induced stress ratio. In depth analysis and recommendations are presented pertaining to stress concentrations resulting from the manufacturing process of FRP composite shapes. Strain data of bridge members were analyzed to arrive at factors of safety for different categories of member shapes utilized in the structural systems. Further strain data analysis pertaining to members of a bridge system are related to the response phenomenon occurring in individual component testing.","abstract_has_math":false,"creators":["Carey, Maxwell Browning"],"institution":null,"degree_name":"MS","degree_level":"Problem/Project Report","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":["Hota GangaRao","P. V. Vijay","Chao Zhang"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:20:58Z","subjects":["FRP","composite","pedestrian bridge","buckling","truss bridge","bridge testing","bridge analysis","bridge safety","Structural Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/12409"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/12409","href":"https://researchrepository.wvu.edu/etd/12409","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.12409","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.12409","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-13130","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Hota GangaRao","P. V. Vijay","Chao Zhang"]},{"key":"dc:creator","label":"Author","values":["Carey, Maxwell Browning"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2024-04-25T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2024-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Problem/Project Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["FRP","composite","pedestrian bridge","buckling","truss bridge","bridge testing","bridge analysis","bridge safety","Structural Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.12409","https://researchrepository.wvu.edu/etd/12409"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Fiber-reinforced polymer (FRP) composites have become mainstream structural materials and are being utilized in many different structural applications because of their outstanding thermos-mechanical properties and other characteristics. These characteristics include exceptional corrosion resistance, energy absorption, durability, high strength-to-weight, stiffness-to-weight ratios, and others. Also, FRP composites are cost effective especially when accounting for the service life of such a material. In this study, testing and analysis were performed at both the component as well as a structural system levels. Herein, two FRP truss bridges of different widths with 50 ft. spans underwent extensive testing and analysis in accordance with AASHTO specifications. Data analyzed includes strains, deflections, and frequencies under static and dynamic loads. Individual members were tested to explain how the behavior of a member alone influences the response of a structural system. Structural responses of the two FRP truss bridges under static, vertical, and pseudo-static wind loads were analyzed and reported, and future design recommendations are made. FRP bridge components under axial compression testing exhibited crushing, local buckling, and lateral torsional buckling failures depending on the span to depth ratio of the components and also as a function of stiffness to induced stress ratio. In depth analysis and recommendations are presented pertaining to stress concentrations resulting from the manufacturing process of FRP composite shapes. Strain data of bridge members were analyzed to arrive at factors of safety for different categories of member shapes utilized in the structural systems. Further strain data analysis pertaining to members of a bridge system are related to the response phenomenon occurring in individual component testing."]},{"key":"dc:title","label":"Title","values":["Evaluation of 50’ FRP Truss Bridges with Timber Decks"]}]}],"canonical_facts":{"dc:contributor":["Hota GangaRao","P. V. Vijay","Chao Zhang"],"dc:creator":["Carey, Maxwell Browning"],"dc:date.available":["2024-04-25T07:00:00Z"],"dc:date.created":["2024-01-01T08:00:00Z"],"dc:description.abstract":["Fiber-reinforced polymer (FRP) composites have become mainstream structural materials and are being utilized in many different structural applications because of their outstanding thermos-mechanical properties and other characteristics. These characteristics include exceptional corrosion resistance, energy absorption, durability, high strength-to-weight, stiffness-to-weight ratios, and others. Also, FRP composites are cost effective especially when accounting for the service life of such a material. In this study, testing and analysis were performed at both the component as well as a structural system levels. Herein, two FRP truss bridges of different widths with 50 ft. spans underwent extensive testing and analysis in accordance with AASHTO specifications. Data analyzed includes strains, deflections, and frequencies under static and dynamic loads. Individual members were tested to explain how the behavior of a member alone influences the response of a structural system. Structural responses of the two FRP truss bridges under static, vertical, and pseudo-static wind loads were analyzed and reported, and future design recommendations are made. FRP bridge components under axial compression testing exhibited crushing, local buckling, and lateral torsional buckling failures depending on the span to depth ratio of the components and also as a function of stiffness to induced stress ratio. In depth analysis and recommendations are presented pertaining to stress concentrations resulting from the manufacturing process of FRP composite shapes. Strain data of bridge members were analyzed to arrive at factors of safety for different categories of member shapes utilized in the structural systems. Further strain data analysis pertaining to members of a bridge system are related to the response phenomenon occurring in individual component testing."],"dc:identifier":["https://doi.org/10.33915/etd.12409","https://researchrepository.wvu.edu/etd/12409"],"dc:subject":["FRP","composite","pedestrian bridge","buckling","truss bridge","bridge testing","bridge analysis","bridge safety","Structural Engineering"],"dc:title":["Evaluation of 50’ FRP Truss Bridges with Timber Decks"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Problem/Project Report"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:20:58Z"}