{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-13641"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-13641","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY (micro-CT) ANALYSIS PART II","abstract":"Abstract A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS Andrew Marra, D.D.S. Introduction: Researchers have compared many endodontic root-end filling techniques for porosity, though few have used a micro-computed tomography analysis for comparisons. The purpose of this study was to evaluate total porosity volume of three different bio-ceramics filling materials with two techniques--hand compaction versus hand/ultrasonic compaction at an ultrasonic setting of 5% using Micro-CT Analysis. Methods: Seventy-two human single canaled extracted teeth were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection at 3-mm from the apex with a 90° slice to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip with a setting of 5%. Samples were assigned to six groups (n = 12 per group) according to the filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results did not show a significant difference between the total of hand compaction alone versus the hand/ultrasonic compaction (p-value = 0.603). There was no significant difference between each material when comparing hand compaction alone versus hand/ultrasonic compaction. MTA (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.318, BD (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.443, and BC (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.378. Conclusion: Within the limitations of this in vitro study, both hand compaction alone and hand/ultrasonic compaction resulted in similar total porosity volume.","abstract_html":"Abstract A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS Andrew Marra, D.D.S. Introduction: Researchers have compared many endodontic root-end filling techniques for porosity, though few have used a micro-computed tomography analysis for comparisons. The purpose of this study was to evaluate total porosity volume of three different bio-ceramics filling materials with two techniques--hand compaction versus hand/ultrasonic compaction at an ultrasonic setting of 5% using Micro-CT Analysis. Methods: Seventy-two human single canaled extracted teeth were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection at 3-mm from the apex with a 90° slice to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip with a setting of 5%. Samples were assigned to six groups (n = 12 per group) according to the filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results did not show a significant difference between the total of hand compaction alone versus the hand/ultrasonic compaction (p-value = 0.603). There was no significant difference between each material when comparing hand compaction alone versus hand/ultrasonic compaction. MTA (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.318, BD (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.443, and BC (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.378. Conclusion: Within the limitations of this in vitro study, both hand compaction alone and hand/ultrasonic compaction resulted in similar total porosity volume.","abstract_has_math":false,"creators":["Marra, Andrew M"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Not Listed","degree_department":null,"school":null,"contributors":["Samuel Dorn","Steven Whitaker","Constance Wiener"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:21:35Z","subjects":["Ultrasonics","Apicoectomy","Micro-CT","Bioceramics","Endodontics and Endodontology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0005-1360-2099\">https://orcid.org/0009-0005-1360-2099</a></p>","https://researchrepository.wvu.edu/etd/12952"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0009-0005-1360-2099\">https://orcid.org/0009-0005-1360-2099</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/12952","href":"https://researchrepository.wvu.edu/etd/12952","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.12952","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.12952","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-13641","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Samuel Dorn","Steven Whitaker","Constance Wiener"]},{"key":"dc:creator","label":"Author","values":["Marra, Andrew M"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Not Listed"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Ultrasonics","Apicoectomy","Micro-CT","Bioceramics","Endodontics and Endodontology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0005-1360-2099\">https://orcid.org/0009-0005-1360-2099</a></p>","https://doi.org/10.33915/etd.12952","https://researchrepository.wvu.edu/etd/12952"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Abstract A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS Andrew Marra, D.D.S. Introduction: Researchers have compared many endodontic root-end filling techniques for porosity, though few have used a micro-computed tomography analysis for comparisons. The purpose of this study was to evaluate total porosity volume of three different bio-ceramics filling materials with two techniques--hand compaction versus hand/ultrasonic compaction at an ultrasonic setting of 5% using Micro-CT Analysis. Methods: Seventy-two human single canaled extracted teeth were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection at 3-mm from the apex with a 90° slice to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip with a setting of 5%. Samples were assigned to six groups (n = 12 per group) according to the filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results did not show a significant difference between the total of hand compaction alone versus the hand/ultrasonic compaction (p-value = 0.603). There was no significant difference between each material when comparing hand compaction alone versus hand/ultrasonic compaction. MTA (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.318, BD (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.443, and BC (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.378. Conclusion: Within the limitations of this in vitro study, both hand compaction alone and hand/ultrasonic compaction resulted in similar total porosity volume."]},{"key":"dc:title","label":"Title","values":["A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY (micro-CT) ANALYSIS PART II"]}]}],"canonical_facts":{"dc:contributor":["Samuel Dorn","Steven Whitaker","Constance Wiener"],"dc:creator":["Marra, Andrew M"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Abstract A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY ANALYSIS Andrew Marra, D.D.S. Introduction: Researchers have compared many endodontic root-end filling techniques for porosity, though few have used a micro-computed tomography analysis for comparisons. The purpose of this study was to evaluate total porosity volume of three different bio-ceramics filling materials with two techniques--hand compaction versus hand/ultrasonic compaction at an ultrasonic setting of 5% using Micro-CT Analysis. Methods: Seventy-two human single canaled extracted teeth were selected for the study. All were subjected to orthograde endodontic treatment followed by root tip resection at 3-mm from the apex with a 90° slice to the long axis of the root. A standard retrograde preparation of 3-mm depth was created with an ultrasonic tip with a setting of 5%. Samples were assigned to six groups (n = 12 per group) according to the filling material and method used: ProRoot® MTA compacted by hand alone; ProRoot® MTA compacted by hand/ultrasonic compaction; Biodentine® compacted by hand alone; Biodentine® compacted by hand/ultrasonic compaction; EndoSequence® BC putty compacted by hand alone; and EndoSequence® BC compacted by hand/ultrasonic compaction. Teeth were scanned with micro-CT to evaluate total porosity volume. A Wilcoxon test was conducted to determine if there was a difference between the groups compacted by hand alone and the hand/ultrasonic compaction group. Results: The results did not show a significant difference between the total of hand compaction alone versus the hand/ultrasonic compaction (p-value = 0.603). There was no significant difference between each material when comparing hand compaction alone versus hand/ultrasonic compaction. MTA (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.318, BD (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.443, and BC (hand compaction alone versus hand/ultrasonic compactions) yielded a p-value of 0.378. Conclusion: Within the limitations of this in vitro study, both hand compaction alone and hand/ultrasonic compaction resulted in similar total porosity volume."],"dc:identifier":["<p><a href=\"https://orcid.org/0009-0005-1360-2099\">https://orcid.org/0009-0005-1360-2099</a></p>","https://doi.org/10.33915/etd.12952","https://researchrepository.wvu.edu/etd/12952"],"dc:subject":["Ultrasonics","Apicoectomy","Micro-CT","Bioceramics","Endodontics and Endodontology"],"dc:title":["A COMPARISON OF ENDODONTIC ROOT-END FILLING TECHNIQUES: A MICRO-COMPUTED TOMOGRAPHY (micro-CT) ANALYSIS PART II"],"thesis:degree_discipline":["Not Listed"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:21:35Z"}