{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-13735"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-13735","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Comparative Analysis of Electrode Encapsulation Reliability: Planar vs. Thermoformed Interdigitated Neural Electrodes in Biomedical Engineering","abstract":"Durable dielectric encapsulation is crucial for the long-term function of implantable neural electrodes; however, the reliability of curved, thermoformed coatings remains underexplored. This study addresses that gap by comparing planar (non-thermoformed) and thermoformed interdigitated neural electrodes (IDEs) encapsulated in Polyimide-2611. Both device types underwent accelerated in vitro aging in phosphate‑buffered saline (PBS) at 67 °C for approximately 91 days, simulating two years of physiological exposure. Post-accelerated aging evaluation included electrochemical impedance spectroscopy (EIS) from 0.1 Hz to 100 kHz to monitor moisture‑induced leakage, and high‑voltage breakdown testing under saline immersion to assess dielectric strength. After aging, all electrodes maintained impedance magnitudes above 10⁹ Ω at 0.1 Hz, 10⁶ Ω at 1 kHz, and 10⁴ Ω at 100 kHz. Initial breakdown voltages for Channel 1 averaged 3.4 kV for planar electrodes and 3.2 kV for thermoformed electrodes, indicating comparable insulation performance. Failure‑mode analysis localized leaks to the integration procedure at the solder pad interface rather than to the bulk polyimide film. These results demonstrate that thermoforming enables anatomically conformal electrode geometries without compromising long‑term encapsulation integrity, supporting the development of flexible neural interfaces.","abstract_html":"Durable dielectric encapsulation is crucial for the long-term function of implantable neural electrodes; however, the reliability of curved, thermoformed coatings remains underexplored. This study addresses that gap by comparing planar (non-thermoformed) and thermoformed interdigitated neural electrodes (IDEs) encapsulated in Polyimide-2611. Both device types underwent accelerated in vitro aging in phosphate‑buffered saline (PBS) at 67 °C for approximately 91 days, simulating two years of physiological exposure. Post-accelerated aging evaluation included electrochemical impedance spectroscopy (EIS) from 0.1 Hz to 100 kHz to monitor moisture‑induced leakage, and high‑voltage breakdown testing under saline immersion to assess dielectric strength. After aging, all electrodes maintained impedance magnitudes above 10⁹ Ω at 0.1 Hz, 10⁶ Ω at 1 kHz, and 10⁴ Ω at 100 kHz. Initial breakdown voltages for Channel 1 averaged 3.4 kV for planar electrodes and 3.2 kV for thermoformed electrodes, indicating comparable insulation performance. Failure‑mode analysis localized leaks to the integration procedure at the solder pad interface rather than to the bulk polyimide film. These results demonstrate that thermoforming enables anatomically conformal electrode geometries without compromising long‑term encapsulation integrity, supporting the development of flexible neural interfaces.","abstract_has_math":false,"creators":["Peyerl, Tatum"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Chemical and Biomedical Engineering","degree_department":null,"school":null,"contributors":["Stephen Cain","Loren Rieth","Xueyan Song"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:21:44Z","subjects":["Neural Electrodes","Electrode Lifetime","Accelerated Aging","Encapsulation","Polyimide","Thermoforming Electrodes","Bioelectrical and Neuroengineering","Biological Engineering","Biomaterials","Biomedical Devices and Instrumentation"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0009-8310-7244\">https://orcid.org/0009-0009-8310-7244</a></p>","https://researchrepository.wvu.edu/etd/13011"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0009-0009-8310-7244\">https://orcid.org/0009-0009-8310-7244</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/13011","href":"https://researchrepository.wvu.edu/etd/13011","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.13011","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.13011","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-13735","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stephen Cain","Loren Rieth","Xueyan Song"]},{"key":"dc:creator","label":"Author","values":["Peyerl, Tatum"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2025-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Chemical and Biomedical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Neural Electrodes","Electrode Lifetime","Accelerated Aging","Encapsulation","Polyimide","Thermoforming Electrodes","Bioelectrical and Neuroengineering","Biological Engineering","Biomaterials","Biomedical Devices and Instrumentation"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0009-8310-7244\">https://orcid.org/0009-0009-8310-7244</a></p>","https://doi.org/10.33915/etd.13011","https://researchrepository.wvu.edu/etd/13011"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Durable dielectric encapsulation is crucial for the long-term function of implantable neural electrodes; however, the reliability of curved, thermoformed coatings remains underexplored. This study addresses that gap by comparing planar (non-thermoformed) and thermoformed interdigitated neural electrodes (IDEs) encapsulated in Polyimide-2611. Both device types underwent accelerated in vitro aging in phosphate‑buffered saline (PBS) at 67 °C for approximately 91 days, simulating two years of physiological exposure. Post-accelerated aging evaluation included electrochemical impedance spectroscopy (EIS) from 0.1 Hz to 100 kHz to monitor moisture‑induced leakage, and high‑voltage breakdown testing under saline immersion to assess dielectric strength. After aging, all electrodes maintained impedance magnitudes above 10⁹ Ω at 0.1 Hz, 10⁶ Ω at 1 kHz, and 10⁴ Ω at 100 kHz. Initial breakdown voltages for Channel 1 averaged 3.4 kV for planar electrodes and 3.2 kV for thermoformed electrodes, indicating comparable insulation performance. Failure‑mode analysis localized leaks to the integration procedure at the solder pad interface rather than to the bulk polyimide film. These results demonstrate that thermoforming enables anatomically conformal electrode geometries without compromising long‑term encapsulation integrity, supporting the development of flexible neural interfaces."]},{"key":"dc:title","label":"Title","values":["Comparative Analysis of Electrode Encapsulation Reliability: Planar vs. Thermoformed Interdigitated Neural Electrodes in Biomedical Engineering"]}]}],"canonical_facts":{"dc:contributor":["Stephen Cain","Loren Rieth","Xueyan Song"],"dc:creator":["Peyerl, Tatum"],"dc:date.created":["2025-01-01T08:00:00Z"],"dc:description.abstract":["Durable dielectric encapsulation is crucial for the long-term function of implantable neural electrodes; however, the reliability of curved, thermoformed coatings remains underexplored. This study addresses that gap by comparing planar (non-thermoformed) and thermoformed interdigitated neural electrodes (IDEs) encapsulated in Polyimide-2611. Both device types underwent accelerated in vitro aging in phosphate‑buffered saline (PBS) at 67 °C for approximately 91 days, simulating two years of physiological exposure. Post-accelerated aging evaluation included electrochemical impedance spectroscopy (EIS) from 0.1 Hz to 100 kHz to monitor moisture‑induced leakage, and high‑voltage breakdown testing under saline immersion to assess dielectric strength. After aging, all electrodes maintained impedance magnitudes above 10⁹ Ω at 0.1 Hz, 10⁶ Ω at 1 kHz, and 10⁴ Ω at 100 kHz. Initial breakdown voltages for Channel 1 averaged 3.4 kV for planar electrodes and 3.2 kV for thermoformed electrodes, indicating comparable insulation performance. Failure‑mode analysis localized leaks to the integration procedure at the solder pad interface rather than to the bulk polyimide film. These results demonstrate that thermoforming enables anatomically conformal electrode geometries without compromising long‑term encapsulation integrity, supporting the development of flexible neural interfaces."],"dc:identifier":["<p><a href=\"https://orcid.org/0009-0009-8310-7244\">https://orcid.org/0009-0009-8310-7244</a></p>","https://doi.org/10.33915/etd.13011","https://researchrepository.wvu.edu/etd/13011"],"dc:subject":["Neural Electrodes","Electrode Lifetime","Accelerated Aging","Encapsulation","Polyimide","Thermoforming Electrodes","Bioelectrical and Neuroengineering","Biological Engineering","Biomaterials","Biomedical Devices and Instrumentation"],"dc:title":["Comparative Analysis of Electrode Encapsulation Reliability: Planar vs. Thermoformed Interdigitated Neural Electrodes in Biomedical Engineering"],"thesis:degree_discipline":["Chemical and Biomedical Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:21:44Z"}