{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-13910"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-13910","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments","abstract":"Abstract Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. This dissertation looks at the ongoing issue of tiny airborne particles created during medical and dental procedures and evaluates ways to reduce the risk of exposure for healthcare workers and patients to these particles. The first study focuses on the size, how long particles stay in the air, and how far they travel from common medical procedures that create aerosols, showing that tiny particles (less than 5 µm) can stay in the air long enough to escape basic droplet controls. As a transition, the second study compares three air curtain configurations, i.e., Push, Pull, and Push-Pull, in a purpose-built dual-compartment chamber and demonstrates that a well-tuned Push-Pull arrangement consistently delivers the best containment (≈95% under optimized conditions), maintains performance when modest obstructions are introduced, and outperforms single-stream designs. The third study translates the chamber results to realistic clinical rooms by applying Reynolds and Euler number as a dimensionless parameter for scaling and regression based predictions. The scaled models indicate that Push-Pull system can achieve comparable containment in full scale settings, when properly calibrated and integrated with existing ventilation. These studies show that combining targeted engineering controls with routine ventilation and personal protective equipment reduces aerosol escape from procedural zones. The studies also provide partial parameters (jet velocity, nozzle geometry, and pressure balance) to guide clinical implementation.","abstract_html":"Abstract Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. This dissertation looks at the ongoing issue of tiny airborne particles created during medical and dental procedures and evaluates ways to reduce the risk of exposure for healthcare workers and patients to these particles. The first study focuses on the size, how long particles stay in the air, and how far they travel from common medical procedures that create aerosols, showing that tiny particles (less than 5 µm) can stay in the air long enough to escape basic droplet controls. As a transition, the second study compares three air curtain configurations, i.e., Push, Pull, and Push-Pull, in a purpose-built dual-compartment chamber and demonstrates that a well-tuned Push-Pull arrangement consistently delivers the best containment (≈95% under optimized conditions), maintains performance when modest obstructions are introduced, and outperforms single-stream designs. The third study translates the chamber results to realistic clinical rooms by applying Reynolds and Euler number as a dimensionless parameter for scaling and regression based predictions. The scaled models indicate that Push-Pull system can achieve comparable containment in full scale settings, when properly calibrated and integrated with existing ventilation. These studies show that combining targeted engineering controls with routine ventilation and personal protective equipment reduces aerosol escape from procedural zones. The studies also provide partial parameters (jet velocity, nozzle geometry, and pressure balance) to guide clinical implementation.","abstract_has_math":false,"creators":["Mutairi, Manal"],"institution":null,"degree_name":"PhD","degree_level":"Dissertation","degree_discipline":"Occupational & Environmental Health Sciences","degree_department":null,"school":null,"contributors":["Michael McCawley","Sijin Wen","Christopher Martin","Marcus Cervantes"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:21:57Z","subjects":["bioaerosols","aerosol-generating procedures","infection control","air curtain","push-pull system","containment efficiency","jet velocity","stopping distance Reynolds number","scaling methodology","Elementary Particles and Fields and String Theory","Environmental Public Health","Fluid Dynamics","Occupational Health and Industrial Hygiene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0000-4846-5809\">https://orcid.org/0009-0000-4846-5809</a></p>","https://researchrepository.wvu.edu/etd/13179"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0009-0000-4846-5809\">https://orcid.org/0009-0000-4846-5809</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/13179","href":"https://researchrepository.wvu.edu/etd/13179","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.13179","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.13179","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-13910","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Michael McCawley","Sijin Wen","Christopher Martin","Marcus Cervantes"]},{"key":"dc:creator","label":"Author","values":["Mutairi, Manal"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Occupational & Environmental Health Sciences"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["bioaerosols","aerosol-generating procedures","infection control","air curtain","push-pull system","containment efficiency","jet velocity","stopping distance Reynolds number","scaling methodology","Elementary Particles and Fields and String Theory","Environmental Public Health","Fluid Dynamics","Occupational Health and Industrial Hygiene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0000-4846-5809\">https://orcid.org/0009-0000-4846-5809</a></p>","https://doi.org/10.33915/etd.13179","https://researchrepository.wvu.edu/etd/13179"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Abstract Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. This dissertation looks at the ongoing issue of tiny airborne particles created during medical and dental procedures and evaluates ways to reduce the risk of exposure for healthcare workers and patients to these particles. The first study focuses on the size, how long particles stay in the air, and how far they travel from common medical procedures that create aerosols, showing that tiny particles (less than 5 µm) can stay in the air long enough to escape basic droplet controls. As a transition, the second study compares three air curtain configurations, i.e., Push, Pull, and Push-Pull, in a purpose-built dual-compartment chamber and demonstrates that a well-tuned Push-Pull arrangement consistently delivers the best containment (≈95% under optimized conditions), maintains performance when modest obstructions are introduced, and outperforms single-stream designs. The third study translates the chamber results to realistic clinical rooms by applying Reynolds and Euler number as a dimensionless parameter for scaling and regression based predictions. The scaled models indicate that Push-Pull system can achieve comparable containment in full scale settings, when properly calibrated and integrated with existing ventilation. These studies show that combining targeted engineering controls with routine ventilation and personal protective equipment reduces aerosol escape from procedural zones. The studies also provide partial parameters (jet velocity, nozzle geometry, and pressure balance) to guide clinical implementation."]},{"key":"dc:title","label":"Title","values":["Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments"]}]}],"canonical_facts":{"dc:contributor":["Michael McCawley","Sijin Wen","Christopher Martin","Marcus Cervantes"],"dc:creator":["Mutairi, Manal"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:description.abstract":["Abstract Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments. This dissertation looks at the ongoing issue of tiny airborne particles created during medical and dental procedures and evaluates ways to reduce the risk of exposure for healthcare workers and patients to these particles. The first study focuses on the size, how long particles stay in the air, and how far they travel from common medical procedures that create aerosols, showing that tiny particles (less than 5 µm) can stay in the air long enough to escape basic droplet controls. As a transition, the second study compares three air curtain configurations, i.e., Push, Pull, and Push-Pull, in a purpose-built dual-compartment chamber and demonstrates that a well-tuned Push-Pull arrangement consistently delivers the best containment (≈95% under optimized conditions), maintains performance when modest obstructions are introduced, and outperforms single-stream designs. The third study translates the chamber results to realistic clinical rooms by applying Reynolds and Euler number as a dimensionless parameter for scaling and regression based predictions. The scaled models indicate that Push-Pull system can achieve comparable containment in full scale settings, when properly calibrated and integrated with existing ventilation. These studies show that combining targeted engineering controls with routine ventilation and personal protective equipment reduces aerosol escape from procedural zones. The studies also provide partial parameters (jet velocity, nozzle geometry, and pressure balance) to guide clinical implementation."],"dc:identifier":["<p><a href=\"https://orcid.org/0009-0000-4846-5809\">https://orcid.org/0009-0000-4846-5809</a></p>","https://doi.org/10.33915/etd.13179","https://researchrepository.wvu.edu/etd/13179"],"dc:subject":["bioaerosols","aerosol-generating procedures","infection control","air curtain","push-pull system","containment efficiency","jet velocity","stopping distance Reynolds number","scaling methodology","Elementary Particles and Fields and String Theory","Environmental Public Health","Fluid Dynamics","Occupational Health and Industrial Hygiene"],"dc:title":["Comparison of Push-Pull Air Curtain to Overhead Downdraft Systems on Aerosol Containment and Distribution in Controlled Environments"],"thesis:degree_discipline":["Occupational & Environmental Health Sciences"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T09:21:57Z"}