{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-14224"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-14224","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Multi-Sensor Fusion for Manual Wheelchair State Estimation","abstract":"Kathylee Pinnock Branford Manual wheelchairs are essential to mobility and independence, yet accurately characterizing wheelchair motion in real-world environments remains challenging. Inertial measurement units (IMUs) provide a practical means of estimating wheelchair kinematics, but existing trajectory-reconstruction studies have largely been limited to short, controlled trials. This report developed and evaluated a four-IMU framework comprising one sensor on each rear wheel and two sensors on the wheelchair frame. Three orientation algorithms (VQF, Mahony AHRS, and Madgwick AHRS), two accelerometer ranges (±2 g and ± 4 g), and calibrated and uncalibrated sensor data were evaluated during indoor motion-capture trials and a outdoor campus route. Indoor trajectories were most accurately reconstructed using frame-based Madgwick AHRS, with two dimensional position RMSE as low as 0.116 m for the fused estimate in the repeated-turning trial. Outdoors, the ±2 g configuration produced substantially lower trajectory and slope errors than the ±4 g configuration. For the representative calibrated ±2 g trial, ChairL-VQF produced the lowest GPS-referenced two-dimensional position RMSE (8.67 m), while ChairR-VQF produced the lowest full-trial relative loop-closure error (0.29%). Terrain and ramp slope were estimated most accurately using ChairR-Madgwick AHRS, with RMSE values of 1.21° and 2.22°, respectively. Calibration had little effect on the ±2 g results but was essential for the ±4 g configuration, for which uncalibrated data produced implausible trajectory estimates. These findings support the use of calibrated ±2 g sensors, with VQF prioritized for long-duration trajectory reconstruction and Madgwick AHRS prioritized for slope estimation.","abstract_html":"Kathylee Pinnock Branford Manual wheelchairs are essential to mobility and independence, yet accurately characterizing wheelchair motion in real-world environments remains challenging. Inertial measurement units (IMUs) provide a practical means of estimating wheelchair kinematics, but existing trajectory-reconstruction studies have largely been limited to short, controlled trials. This report developed and evaluated a four-IMU framework comprising one sensor on each rear wheel and two sensors on the wheelchair frame. Three orientation algorithms (VQF, Mahony AHRS, and Madgwick AHRS), two accelerometer ranges (±2 g and ± 4 g), and calibrated and uncalibrated sensor data were evaluated during indoor motion-capture trials and a outdoor campus route. Indoor trajectories were most accurately reconstructed using frame-based Madgwick AHRS, with two dimensional position RMSE as low as 0.116 m for the fused estimate in the repeated-turning trial. Outdoors, the ±2 g configuration produced substantially lower trajectory and slope errors than the ±4 g configuration. For the representative calibrated ±2 g trial, ChairL-VQF produced the lowest GPS-referenced two-dimensional position RMSE (8.67 m), while ChairR-VQF produced the lowest full-trial relative loop-closure error (0.29%). Terrain and ramp slope were estimated most accurately using ChairR-Madgwick AHRS, with RMSE values of 1.21° and 2.22°, respectively. Calibration had little effect on the ±2 g results but was essential for the ±4 g configuration, for which uncalibrated data produced implausible trajectory estimates. These findings support the use of calibrated ±2 g sensors, with VQF prioritized for long-duration trajectory reconstruction and Madgwick AHRS prioritized for slope estimation.","abstract_has_math":false,"creators":["Pinnock Branford, Kathylee"],"institution":null,"degree_name":"MS","degree_level":"Problem/Project Report","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":["Stephen M. Cain","Nicholas Szczecinski","Natalia Schmid"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:28:06Z","subjects":["spinal cord injury","manual wheelchair users","inertial measurement units","free-living monitoring","shoulder exposure","wheelchair propulsion","upper extremity loading","activities of daily living","environmental accessibility","Biomechanical Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0002-2991-7384\">https://orcid.org/0009-0002-2991-7384</a></p>","https://researchrepository.wvu.edu/etd/13492"],"render_values":[{"text":"<p><a href=\"https://orcid.org/0009-0002-2991-7384\">https://orcid.org/0009-0002-2991-7384</a></p>","href":null,"code":true},{"text":"https://researchrepository.wvu.edu/etd/13492","href":"https://researchrepository.wvu.edu/etd/13492","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.13492","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.13492","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-14224","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Stephen M. Cain","Nicholas Szczecinski","Natalia Schmid"]},{"key":"dc:creator","label":"Author","values":["Pinnock Branford, Kathylee"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2026-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Problem/Project Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["spinal cord injury","manual wheelchair users","inertial measurement units","free-living monitoring","shoulder exposure","wheelchair propulsion","upper extremity loading","activities of daily living","environmental accessibility","Biomechanical Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["<p><a href=\"https://orcid.org/0009-0002-2991-7384\">https://orcid.org/0009-0002-2991-7384</a></p>","https://doi.org/10.33915/etd.13492","https://researchrepository.wvu.edu/etd/13492"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Kathylee Pinnock Branford Manual wheelchairs are essential to mobility and independence, yet accurately characterizing wheelchair motion in real-world environments remains challenging. Inertial measurement units (IMUs) provide a practical means of estimating wheelchair kinematics, but existing trajectory-reconstruction studies have largely been limited to short, controlled trials. This report developed and evaluated a four-IMU framework comprising one sensor on each rear wheel and two sensors on the wheelchair frame. Three orientation algorithms (VQF, Mahony AHRS, and Madgwick AHRS), two accelerometer ranges (±2 g and ± 4 g), and calibrated and uncalibrated sensor data were evaluated during indoor motion-capture trials and a outdoor campus route. Indoor trajectories were most accurately reconstructed using frame-based Madgwick AHRS, with two dimensional position RMSE as low as 0.116 m for the fused estimate in the repeated-turning trial. Outdoors, the ±2 g configuration produced substantially lower trajectory and slope errors than the ±4 g configuration. For the representative calibrated ±2 g trial, ChairL-VQF produced the lowest GPS-referenced two-dimensional position RMSE (8.67 m), while ChairR-VQF produced the lowest full-trial relative loop-closure error (0.29%). Terrain and ramp slope were estimated most accurately using ChairR-Madgwick AHRS, with RMSE values of 1.21° and 2.22°, respectively. Calibration had little effect on the ±2 g results but was essential for the ±4 g configuration, for which uncalibrated data produced implausible trajectory estimates. These findings support the use of calibrated ±2 g sensors, with VQF prioritized for long-duration trajectory reconstruction and Madgwick AHRS prioritized for slope estimation."]},{"key":"dc:description.note","label":"Dc Description Note","values":["<p>I addressed the requested changes </p>"]},{"key":"dc:title","label":"Title","values":["Multi-Sensor Fusion for Manual Wheelchair State Estimation"]}]}],"canonical_facts":{"dc:contributor":["Stephen M. Cain","Nicholas Szczecinski","Natalia Schmid"],"dc:creator":["Pinnock Branford, Kathylee"],"dc:date.created":["2026-01-01T08:00:00Z"],"dc:description.abstract":["Kathylee Pinnock Branford Manual wheelchairs are essential to mobility and independence, yet accurately characterizing wheelchair motion in real-world environments remains challenging. Inertial measurement units (IMUs) provide a practical means of estimating wheelchair kinematics, but existing trajectory-reconstruction studies have largely been limited to short, controlled trials. This report developed and evaluated a four-IMU framework comprising one sensor on each rear wheel and two sensors on the wheelchair frame. Three orientation algorithms (VQF, Mahony AHRS, and Madgwick AHRS), two accelerometer ranges (±2 g and ± 4 g), and calibrated and uncalibrated sensor data were evaluated during indoor motion-capture trials and a outdoor campus route. Indoor trajectories were most accurately reconstructed using frame-based Madgwick AHRS, with two dimensional position RMSE as low as 0.116 m for the fused estimate in the repeated-turning trial. Outdoors, the ±2 g configuration produced substantially lower trajectory and slope errors than the ±4 g configuration. For the representative calibrated ±2 g trial, ChairL-VQF produced the lowest GPS-referenced two-dimensional position RMSE (8.67 m), while ChairR-VQF produced the lowest full-trial relative loop-closure error (0.29%). Terrain and ramp slope were estimated most accurately using ChairR-Madgwick AHRS, with RMSE values of 1.21° and 2.22°, respectively. Calibration had little effect on the ±2 g results but was essential for the ±4 g configuration, for which uncalibrated data produced implausible trajectory estimates. These findings support the use of calibrated ±2 g sensors, with VQF prioritized for long-duration trajectory reconstruction and Madgwick AHRS prioritized for slope estimation."],"dc:description.note":["<p>I addressed the requested changes </p>"],"dc:identifier":["<p><a href=\"https://orcid.org/0009-0002-2991-7384\">https://orcid.org/0009-0002-2991-7384</a></p>","https://doi.org/10.33915/etd.13492","https://researchrepository.wvu.edu/etd/13492"],"dc:subject":["spinal cord injury","manual wheelchair users","inertial measurement units","free-living monitoring","shoulder exposure","wheelchair propulsion","upper extremity loading","activities of daily living","environmental accessibility","Biomechanical Engineering"],"dc:title":["Multi-Sensor Fusion for Manual Wheelchair State Estimation"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Problem/Project Report"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:28:06Z"}