{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-2406"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-2406","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Standardization of test methods for property evaluation of FRP bars","abstract":"The objective of this research is to verify/modify/develop standardized test methods for evaluating mechanical properties of Fiber Reinforced Polymer (FRP) bars by conducting limited complementary tests to determine/verify their mechanical properties. Both short and long-term tests were conducted as a part of this research. Short-term tests included tension, flexure, shear and bond property evaluations. Long-term tests included evaluation of moisture absorption and flexural tests on aged bars. A total of 229 FRP bars with different fibers (carbon, glass and aramid), varying diameters (# 3 to #8) and surface textures (ribbed, sand-coated, and sand-coated with helical wraps) were tested under this research.;Tension tests were conducted using grips made of split schedule 80 steel pipes that were bonded to the bars using a commercially available resin. Grip lengths based on diameter of FRP bars were established to be varying from 8&inches; to 13.3&inches; for #3 to #8 bars, respectively. Average tensile strengths of FRP bars were found to be 256 ksi (ribbed carbon ), 83 to 77 ksi (ribbed glass), 82 to 67 ksi ( sand coated glass), and 173 ksi (sand coated aramid). (Abstract shortened by UMI.).","abstract_html":"The objective of this research is to verify/modify/develop standardized test methods for evaluating mechanical properties of Fiber Reinforced Polymer (FRP) bars by conducting limited complementary tests to determine/verify their mechanical properties. Both short and long-term tests were conducted as a part of this research. Short-term tests included tension, flexure, shear and bond property evaluations. Long-term tests included evaluation of moisture absorption and flexural tests on aged bars. A total of 229 FRP bars with different fibers (carbon, glass and aramid), varying diameters (# 3 to #8) and surface textures (ribbed, sand-coated, and sand-coated with helical wraps) were tested under this research.;Tension tests were conducted using grips made of split schedule 80 steel pipes that were bonded to the bars using a commercially available resin. Grip lengths based on diameter of FRP bars were established to be varying from 8&amp;inches; to 13.3&amp;inches; for #3 to #8 bars, respectively. Average tensile strengths of FRP bars were found to be 256 ksi (ribbed carbon ), 83 to 77 ksi (ribbed glass), 82 to 67 ksi ( sand coated glass), and 173 ksi (sand coated aramid). (Abstract shortened by UMI.).","abstract_has_math":false,"creators":["Tripathi, Vijay Kumar"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:18:32Z","subjects":["Civil engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/1403"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/1403","href":"https://researchrepository.wvu.edu/etd/1403","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.1403","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.1403","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-2406","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Tripathi, Vijay Kumar"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2003-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.1403","https://researchrepository.wvu.edu/etd/1403"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research is to verify/modify/develop standardized test methods for evaluating mechanical properties of Fiber Reinforced Polymer (FRP) bars by conducting limited complementary tests to determine/verify their mechanical properties. Both short and long-term tests were conducted as a part of this research. Short-term tests included tension, flexure, shear and bond property evaluations. Long-term tests included evaluation of moisture absorption and flexural tests on aged bars. A total of 229 FRP bars with different fibers (carbon, glass and aramid), varying diameters (# 3 to #8) and surface textures (ribbed, sand-coated, and sand-coated with helical wraps) were tested under this research.;Tension tests were conducted using grips made of split schedule 80 steel pipes that were bonded to the bars using a commercially available resin. Grip lengths based on diameter of FRP bars were established to be varying from 8&inches; to 13.3&inches; for #3 to #8 bars, respectively. Average tensile strengths of FRP bars were found to be 256 ksi (ribbed carbon ), 83 to 77 ksi (ribbed glass), 82 to 67 ksi ( sand coated glass), and 173 ksi (sand coated aramid). (Abstract shortened by UMI.)."]},{"key":"dc:title","label":"Title","values":["Standardization of test methods for property evaluation of FRP bars"]}]}],"canonical_facts":{"dc:creator":["Tripathi, Vijay Kumar"],"dc:date.available":["2019-01-17T08:00:00Z"],"dc:date.created":["2003-12-01T08:00:00Z"],"dc:description.abstract":["The objective of this research is to verify/modify/develop standardized test methods for evaluating mechanical properties of Fiber Reinforced Polymer (FRP) bars by conducting limited complementary tests to determine/verify their mechanical properties. Both short and long-term tests were conducted as a part of this research. Short-term tests included tension, flexure, shear and bond property evaluations. Long-term tests included evaluation of moisture absorption and flexural tests on aged bars. A total of 229 FRP bars with different fibers (carbon, glass and aramid), varying diameters (# 3 to #8) and surface textures (ribbed, sand-coated, and sand-coated with helical wraps) were tested under this research.;Tension tests were conducted using grips made of split schedule 80 steel pipes that were bonded to the bars using a commercially available resin. Grip lengths based on diameter of FRP bars were established to be varying from 8&inches; to 13.3&inches; for #3 to #8 bars, respectively. Average tensile strengths of FRP bars were found to be 256 ksi (ribbed carbon ), 83 to 77 ksi (ribbed glass), 82 to 67 ksi ( sand coated glass), and 173 ksi (sand coated aramid). (Abstract shortened by UMI.)."],"dc:identifier":["https://doi.org/10.33915/etd.1403","https://researchrepository.wvu.edu/etd/1403"],"dc:subject":["Civil engineering"],"dc:title":["Standardization of test methods for property evaluation of FRP bars"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:18:32Z"}