{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-2667"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-2667","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Investigation of moisture sensitivity of hot mix asphalt concrete","abstract":"The objective of this research project is to evaluate impact of change in AASHTO T 283 test method on Superpave mix designs in West Virginia. The Lottman test method and Tunnicliff and Root test method were combined into Modified Lottman test procedure and published as AASHTO T 283 in 1985 and revised in 1989. Research was done to establish how the Superpave compaction and conditioning method affect the test results. As a result of this research, AASHTO T 283 test method was revised in 2003. In the 2003 version, use of gyratory compactor was allowed and changes were made to sample preparation, air void tolerance level, sample conditioning method, and method of testing samples. The major change was a mandatory freeze-thaw cycle to condition samples.;This research examined the application of the current AASHTO T 283 applied to West Virginia mixes. It was concluded that this is not a reliable test method for moisture sensitivity. The 2003 version of the test does not improve the ability of the test to identify moisture sensitive mixes. (Abstract shortened by UMI.).","abstract_html":"The objective of this research project is to evaluate impact of change in AASHTO T 283 test method on Superpave mix designs in West Virginia. The Lottman test method and Tunnicliff and Root test method were combined into Modified Lottman test procedure and published as AASHTO T 283 in 1985 and revised in 1989. Research was done to establish how the Superpave compaction and conditioning method affect the test results. As a result of this research, AASHTO T 283 test method was revised in 2003. In the 2003 version, use of gyratory compactor was allowed and changes were made to sample preparation, air void tolerance level, sample conditioning method, and method of testing samples. The major change was a mandatory freeze-thaw cycle to condition samples.;This research examined the application of the current AASHTO T 283 applied to West Virginia mixes. It was concluded that this is not a reliable test method for moisture sensitivity. The 2003 version of the test does not improve the ability of the test to identify moisture sensitive mixes. (Abstract shortened by UMI.).","abstract_has_math":false,"creators":["Viswanathan, Anu Ganesan"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:14:39Z","subjects":["Civil engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/1664"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/1664","href":"https://researchrepository.wvu.edu/etd/1664","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.1664","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.1664","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-2667","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Viswanathan, Anu Ganesan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2005-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.1664","https://researchrepository.wvu.edu/etd/1664"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The objective of this research project is to evaluate impact of change in AASHTO T 283 test method on Superpave mix designs in West Virginia. The Lottman test method and Tunnicliff and Root test method were combined into Modified Lottman test procedure and published as AASHTO T 283 in 1985 and revised in 1989. Research was done to establish how the Superpave compaction and conditioning method affect the test results. As a result of this research, AASHTO T 283 test method was revised in 2003. In the 2003 version, use of gyratory compactor was allowed and changes were made to sample preparation, air void tolerance level, sample conditioning method, and method of testing samples. The major change was a mandatory freeze-thaw cycle to condition samples.;This research examined the application of the current AASHTO T 283 applied to West Virginia mixes. It was concluded that this is not a reliable test method for moisture sensitivity. The 2003 version of the test does not improve the ability of the test to identify moisture sensitive mixes. (Abstract shortened by UMI.)."]},{"key":"dc:title","label":"Title","values":["Investigation of moisture sensitivity of hot mix asphalt concrete"]}]}],"canonical_facts":{"dc:creator":["Viswanathan, Anu Ganesan"],"dc:date.available":["2019-01-17T08:00:00Z"],"dc:date.created":["2005-12-01T08:00:00Z"],"dc:description.abstract":["The objective of this research project is to evaluate impact of change in AASHTO T 283 test method on Superpave mix designs in West Virginia. The Lottman test method and Tunnicliff and Root test method were combined into Modified Lottman test procedure and published as AASHTO T 283 in 1985 and revised in 1989. Research was done to establish how the Superpave compaction and conditioning method affect the test results. As a result of this research, AASHTO T 283 test method was revised in 2003. In the 2003 version, use of gyratory compactor was allowed and changes were made to sample preparation, air void tolerance level, sample conditioning method, and method of testing samples. The major change was a mandatory freeze-thaw cycle to condition samples.;This research examined the application of the current AASHTO T 283 applied to West Virginia mixes. It was concluded that this is not a reliable test method for moisture sensitivity. The 2003 version of the test does not improve the ability of the test to identify moisture sensitive mixes. (Abstract shortened by UMI.)."],"dc:identifier":["https://doi.org/10.33915/etd.1664","https://researchrepository.wvu.edu/etd/1664"],"dc:subject":["Civil engineering"],"dc:title":["Investigation of moisture sensitivity of hot mix asphalt concrete"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:14:39Z"}