{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-3035"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-3035","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Experimental validation of the \"target hood static pressure\" balancing method for exhaust ventilation systems","abstract":"An experimental trial of a new method to balance industrial exhaust ventilation systems was performed. Although balance by design is considered preferable, many ventilation systems incorporate dampers to balance the system to a different airflow distribution after installation. The \"target hood static pressure\" method aims to minimize the time, effort, frustration and confusion invested in the balancing effort. It requires only one and one-half adjustment rounds, can be prepared as a computerized spreadsheet, and substitutes hood static pressure readings for airflow traverse readings. The method also minimizes the system static pressure to the least possible, thereby keeping friction losses at a minimum. Since the resulting distribution errors range less than the measurement error of pitot tube measurements, no method can be demonstrated as being better.","abstract_html":"An experimental trial of a new method to balance industrial exhaust ventilation systems was performed. Although balance by design is considered preferable, many ventilation systems incorporate dampers to balance the system to a different airflow distribution after installation. The &quot;target hood static pressure&quot; method aims to minimize the time, effort, frustration and confusion invested in the balancing effort. It requires only one and one-half adjustment rounds, can be prepared as a computerized spreadsheet, and substitutes hood static pressure readings for airflow traverse readings. The method also minimizes the system static pressure to the least possible, thereby keeping friction losses at a minimum. Since the resulting distribution errors range less than the measurement error of pitot tube measurements, no method can be demonstrated as being better.","abstract_has_math":false,"creators":["Dodrill, Michael Winifred"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:15:01Z","subjects":["Occupational safety","Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/2031"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/2031","href":"https://researchrepository.wvu.edu/etd/2031","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.2031","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.2031","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-3035","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Dodrill, Michael Winifred"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2004-12-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Occupational safety","Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.2031","https://researchrepository.wvu.edu/etd/2031"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["An experimental trial of a new method to balance industrial exhaust ventilation systems was performed. Although balance by design is considered preferable, many ventilation systems incorporate dampers to balance the system to a different airflow distribution after installation. The \"target hood static pressure\" method aims to minimize the time, effort, frustration and confusion invested in the balancing effort. It requires only one and one-half adjustment rounds, can be prepared as a computerized spreadsheet, and substitutes hood static pressure readings for airflow traverse readings. The method also minimizes the system static pressure to the least possible, thereby keeping friction losses at a minimum. Since the resulting distribution errors range less than the measurement error of pitot tube measurements, no method can be demonstrated as being better."]},{"key":"dc:title","label":"Title","values":["Experimental validation of the \"target hood static pressure\" balancing method for exhaust ventilation systems"]}]}],"canonical_facts":{"dc:creator":["Dodrill, Michael Winifred"],"dc:date.available":["2019-01-17T08:00:00Z"],"dc:date.created":["2004-12-01T08:00:00Z"],"dc:description.abstract":["An experimental trial of a new method to balance industrial exhaust ventilation systems was performed. Although balance by design is considered preferable, many ventilation systems incorporate dampers to balance the system to a different airflow distribution after installation. The \"target hood static pressure\" method aims to minimize the time, effort, frustration and confusion invested in the balancing effort. It requires only one and one-half adjustment rounds, can be prepared as a computerized spreadsheet, and substitutes hood static pressure readings for airflow traverse readings. The method also minimizes the system static pressure to the least possible, thereby keeping friction losses at a minimum. Since the resulting distribution errors range less than the measurement error of pitot tube measurements, no method can be demonstrated as being better."],"dc:identifier":["https://doi.org/10.33915/etd.2031","https://researchrepository.wvu.edu/etd/2031"],"dc:subject":["Occupational safety","Mechanical engineering"],"dc:title":["Experimental validation of the \"target hood static pressure\" balancing method for exhaust ventilation systems"],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:15:01Z"}