{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-3361"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-3361","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Sensitivity comparison evaluation of computer-generated three dimensional surface topography to conventional maxillofacial radiographic imagery","abstract":"Objectives. LumenIQ's ImageIQ software enhances conventional radiographs by adding 3-D depth. This study evaluated whether a preference exists for ImageIQ format versus conventional radiographs, determined whether ImageIQ format is as sensitive as 2-D radiographs when detecting existing periodontal defects and simulated periodontal defects. Methods. 34 dental practitioners compared 12 radiographic cases with ImagelQ format. A panel of evaluators classified periodontal defects from 2-D radiographs and ImageIQ images. Simulated periodontal defects were radiographed with various radiographic variables altered, converted to ImageIQ 3-D format, and measured to evaluate the ImageIQ format compared to the 2-D control. Results . ImageIQ format showed improved image clarity and detail over the 2-D. Changes in x-ray beam exposure time, beam angulation, and bone quality had no effect on the ImageIQ format. ImageIQ format improved the accuracy of periodontal defect classification by 14.3% over 2-D. Conclusions . ImageIQ may provide a reliable diagnostic alternative to conventional two-dimensional radiographs.","abstract_html":"Objectives. LumenIQ&#x27;s ImageIQ software enhances conventional radiographs by adding 3-D depth. This study evaluated whether a preference exists for ImageIQ format versus conventional radiographs, determined whether ImageIQ format is as sensitive as 2-D radiographs when detecting existing periodontal defects and simulated periodontal defects. Methods. 34 dental practitioners compared 12 radiographic cases with ImagelQ format. A panel of evaluators classified periodontal defects from 2-D radiographs and ImageIQ images. Simulated periodontal defects were radiographed with various radiographic variables altered, converted to ImageIQ 3-D format, and measured to evaluate the ImageIQ format compared to the 2-D control. Results . ImageIQ format showed improved image clarity and detail over the 2-D. Changes in x-ray beam exposure time, beam angulation, and bone quality had no effect on the ImageIQ format. ImageIQ format improved the accuracy of periodontal defect classification by 14.3% over 2-D. Conclusions . ImageIQ may provide a reliable diagnostic alternative to conventional two-dimensional radiographs.","abstract_has_math":false,"creators":["Hazey, Michael A., III"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Not Listed","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:15:35Z","subjects":["Dentistry","Medical imaging"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/2357"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/2357","href":"https://researchrepository.wvu.edu/etd/2357","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.2357","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.2357","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-3361","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Hazey, Michael A., III"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-05-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Not Listed"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Dentistry","Medical imaging"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.2357","https://researchrepository.wvu.edu/etd/2357"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objectives. LumenIQ's ImageIQ software enhances conventional radiographs by adding 3-D depth. This study evaluated whether a preference exists for ImageIQ format versus conventional radiographs, determined whether ImageIQ format is as sensitive as 2-D radiographs when detecting existing periodontal defects and simulated periodontal defects. Methods. 34 dental practitioners compared 12 radiographic cases with ImagelQ format. A panel of evaluators classified periodontal defects from 2-D radiographs and ImageIQ images. Simulated periodontal defects were radiographed with various radiographic variables altered, converted to ImageIQ 3-D format, and measured to evaluate the ImageIQ format compared to the 2-D control. Results . ImageIQ format showed improved image clarity and detail over the 2-D. Changes in x-ray beam exposure time, beam angulation, and bone quality had no effect on the ImageIQ format. ImageIQ format improved the accuracy of periodontal defect classification by 14.3% over 2-D. Conclusions . ImageIQ may provide a reliable diagnostic alternative to conventional two-dimensional radiographs."]},{"key":"dc:title","label":"Title","values":["Sensitivity comparison evaluation of computer-generated three dimensional surface topography to conventional maxillofacial radiographic imagery"]}]}],"canonical_facts":{"dc:creator":["Hazey, Michael A., III"],"dc:date.available":["2019-01-17T08:00:00Z"],"dc:date.created":["2006-05-01T07:00:00Z"],"dc:description.abstract":["Objectives. LumenIQ's ImageIQ software enhances conventional radiographs by adding 3-D depth. This study evaluated whether a preference exists for ImageIQ format versus conventional radiographs, determined whether ImageIQ format is as sensitive as 2-D radiographs when detecting existing periodontal defects and simulated periodontal defects. Methods. 34 dental practitioners compared 12 radiographic cases with ImagelQ format. A panel of evaluators classified periodontal defects from 2-D radiographs and ImageIQ images. Simulated periodontal defects were radiographed with various radiographic variables altered, converted to ImageIQ 3-D format, and measured to evaluate the ImageIQ format compared to the 2-D control. Results . ImageIQ format showed improved image clarity and detail over the 2-D. Changes in x-ray beam exposure time, beam angulation, and bone quality had no effect on the ImageIQ format. ImageIQ format improved the accuracy of periodontal defect classification by 14.3% over 2-D. Conclusions . ImageIQ may provide a reliable diagnostic alternative to conventional two-dimensional radiographs."],"dc:identifier":["https://doi.org/10.33915/etd.2357","https://researchrepository.wvu.edu/etd/2357"],"dc:subject":["Dentistry","Medical imaging"],"dc:title":["Sensitivity comparison evaluation of computer-generated three dimensional surface topography to conventional maxillofacial radiographic imagery"],"thesis:degree_discipline":["Not Listed"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:15:35Z"}