{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-4247"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-4247","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Technical and economic effectiveness for repair with FRP of concrete T-beam bridges: Case study for PennDOT-District 3","abstract":"The bridge inventory of the Pennsylvania Department of Transportation-District 3 (PennDOT-D3) includes 128 concrete T-Beam bridges built in 1920 to 1960. Due to deterioration over time, a significant number of these bridges are in need of repair or replacement. Traditional methods of repair require temporary bridge-closures and do not provide long-term effective solutions. Moreover, the cost of replacement is not financially viable. Thus, PennDOT D-3 sponsored this project to investigate the technical and economic suitability of a relatively new technology, widely used for seismic retrofit, consisting of externally bonded Fiber-Reinforce Polymer (FRP) for repair and retrofit of concrete T-Beam bridges in particular, but applicable to other bridge structures in PA.;This thesis discusses a case-study project for innovative rehabilitation of cast-in-place concrete T-Beam bridges in PennDOT-D3. The 128 bridges considered are simply-supported structures of 20 to 60-ft span that provide much needed service throughout the District. Although specific to PennDOT-D3 this study presents a general prescription for the possible adoption of FRP for bridge repair and retrofit.;This study describes a method for cataloging candidate bridges from an inventory based on suitability and favorability for repair with externally bonded FRP composites. The rationale for the classification of a set of characteristics is described. This classification is based on inspection data (photographical indication of damage and field verification for representative bridges) and age, span, and ADT/ADTT. From these characteristics, three suitable levels are identified: Class 1 (high), Class 2 (moderate) and Class 3 (low). Correspondingly, 3 repair protocols are recommended: Major (repair contracted out through competitive bid), Moderate (repair performed as a joint effort between state engineers and contractors), and Minor (repair performed entirely by an in-house crew). Comparisons are given for both cost-benefit (future worth) and construction methods for both FRP and conventional repair for these 3 levels. Also, from a synthesis of classification characteristics and repair levels, a prescription for the selection of candidate bridges for trial repair is presented, to implement the technology on Phase II of this project currently underway.","abstract_html":"The bridge inventory of the Pennsylvania Department of Transportation-District 3 (PennDOT-D3) includes 128 concrete T-Beam bridges built in 1920 to 1960. Due to deterioration over time, a significant number of these bridges are in need of repair or replacement. Traditional methods of repair require temporary bridge-closures and do not provide long-term effective solutions. Moreover, the cost of replacement is not financially viable. Thus, PennDOT D-3 sponsored this project to investigate the technical and economic suitability of a relatively new technology, widely used for seismic retrofit, consisting of externally bonded Fiber-Reinforce Polymer (FRP) for repair and retrofit of concrete T-Beam bridges in particular, but applicable to other bridge structures in PA.;This thesis discusses a case-study project for innovative rehabilitation of cast-in-place concrete T-Beam bridges in PennDOT-D3. The 128 bridges considered are simply-supported structures of 20 to 60-ft span that provide much needed service throughout the District. Although specific to PennDOT-D3 this study presents a general prescription for the possible adoption of FRP for bridge repair and retrofit.;This study describes a method for cataloging candidate bridges from an inventory based on suitability and favorability for repair with externally bonded FRP composites. The rationale for the classification of a set of characteristics is described. This classification is based on inspection data (photographical indication of damage and field verification for representative bridges) and age, span, and ADT/ADTT. From these characteristics, three suitable levels are identified: Class 1 (high), Class 2 (moderate) and Class 3 (low). Correspondingly, 3 repair protocols are recommended: Major (repair contracted out through competitive bid), Moderate (repair performed as a joint effort between state engineers and contractors), and Minor (repair performed entirely by an in-house crew). Comparisons are given for both cost-benefit (future worth) and construction methods for both FRP and conventional repair for these 3 levels. Also, from a synthesis of classification characteristics and repair levels, a prescription for the selection of candidate bridges for trial repair is presented, to implement the technology on Phase II of this project currently underway.","abstract_has_math":false,"creators":["Brayack, Daniel A."],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Civil and Environmental Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:18:40Z","subjects":["Civil engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/3243"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/3243","href":"https://researchrepository.wvu.edu/etd/3243","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.3243","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.3243","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-4247","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Brayack, Daniel A."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-01-17T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2006-08-01T07:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil and Environmental Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.3243","https://researchrepository.wvu.edu/etd/3243"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["The bridge inventory of the Pennsylvania Department of Transportation-District 3 (PennDOT-D3) includes 128 concrete T-Beam bridges built in 1920 to 1960. Due to deterioration over time, a significant number of these bridges are in need of repair or replacement. Traditional methods of repair require temporary bridge-closures and do not provide long-term effective solutions. Moreover, the cost of replacement is not financially viable. Thus, PennDOT D-3 sponsored this project to investigate the technical and economic suitability of a relatively new technology, widely used for seismic retrofit, consisting of externally bonded Fiber-Reinforce Polymer (FRP) for repair and retrofit of concrete T-Beam bridges in particular, but applicable to other bridge structures in PA.;This thesis discusses a case-study project for innovative rehabilitation of cast-in-place concrete T-Beam bridges in PennDOT-D3. The 128 bridges considered are simply-supported structures of 20 to 60-ft span that provide much needed service throughout the District. Although specific to PennDOT-D3 this study presents a general prescription for the possible adoption of FRP for bridge repair and retrofit.;This study describes a method for cataloging candidate bridges from an inventory based on suitability and favorability for repair with externally bonded FRP composites. The rationale for the classification of a set of characteristics is described. This classification is based on inspection data (photographical indication of damage and field verification for representative bridges) and age, span, and ADT/ADTT. From these characteristics, three suitable levels are identified: Class 1 (high), Class 2 (moderate) and Class 3 (low). Correspondingly, 3 repair protocols are recommended: Major (repair contracted out through competitive bid), Moderate (repair performed as a joint effort between state engineers and contractors), and Minor (repair performed entirely by an in-house crew). Comparisons are given for both cost-benefit (future worth) and construction methods for both FRP and conventional repair for these 3 levels. Also, from a synthesis of classification characteristics and repair levels, a prescription for the selection of candidate bridges for trial repair is presented, to implement the technology on Phase II of this project currently underway."]},{"key":"dc:title","label":"Title","values":["Technical and economic effectiveness for repair with FRP of concrete T-beam bridges: Case study for PennDOT-District 3"]}]}],"canonical_facts":{"dc:creator":["Brayack, Daniel A."],"dc:date.available":["2019-01-17T08:00:00Z"],"dc:date.created":["2006-08-01T07:00:00Z"],"dc:description.abstract":["The bridge inventory of the Pennsylvania Department of Transportation-District 3 (PennDOT-D3) includes 128 concrete T-Beam bridges built in 1920 to 1960. Due to deterioration over time, a significant number of these bridges are in need of repair or replacement. Traditional methods of repair require temporary bridge-closures and do not provide long-term effective solutions. Moreover, the cost of replacement is not financially viable. Thus, PennDOT D-3 sponsored this project to investigate the technical and economic suitability of a relatively new technology, widely used for seismic retrofit, consisting of externally bonded Fiber-Reinforce Polymer (FRP) for repair and retrofit of concrete T-Beam bridges in particular, but applicable to other bridge structures in PA.;This thesis discusses a case-study project for innovative rehabilitation of cast-in-place concrete T-Beam bridges in PennDOT-D3. The 128 bridges considered are simply-supported structures of 20 to 60-ft span that provide much needed service throughout the District. Although specific to PennDOT-D3 this study presents a general prescription for the possible adoption of FRP for bridge repair and retrofit.;This study describes a method for cataloging candidate bridges from an inventory based on suitability and favorability for repair with externally bonded FRP composites. The rationale for the classification of a set of characteristics is described. This classification is based on inspection data (photographical indication of damage and field verification for representative bridges) and age, span, and ADT/ADTT. From these characteristics, three suitable levels are identified: Class 1 (high), Class 2 (moderate) and Class 3 (low). Correspondingly, 3 repair protocols are recommended: Major (repair contracted out through competitive bid), Moderate (repair performed as a joint effort between state engineers and contractors), and Minor (repair performed entirely by an in-house crew). Comparisons are given for both cost-benefit (future worth) and construction methods for both FRP and conventional repair for these 3 levels. Also, from a synthesis of classification characteristics and repair levels, a prescription for the selection of candidate bridges for trial repair is presented, to implement the technology on Phase II of this project currently underway."],"dc:identifier":["https://doi.org/10.33915/etd.3243","https://researchrepository.wvu.edu/etd/3243"],"dc:subject":["Civil engineering"],"dc:title":["Technical and economic effectiveness for repair with FRP of concrete T-beam bridges: Case study for PennDOT-District 3"],"thesis:degree_discipline":["Civil and Environmental Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:18:40Z"}