{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-5106"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-5106","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Noise monitoring assessment of a northewest fabrication company.","abstract":"This report documents the findings, observations, and recommendations of the investigator's noise assessment survey, performed at a northwest company fabrication building located in Washington State. The assessment was performed at the request of the company's safety management staff and the fabrication building's industrial hygienist between June 6 and July 22, 2014. The goal of the noise assessment was to determine the risk of employees developing noise-induced hearing loss from their work at the company; to update the company's hearing conservation program; and to provide noise reduction recommendations. During the assessment, noise monitoring data was collected through the use of personal noise dosimetry and through the use of a sound level meter. A total of 34 samples were collected from 32 employees using personal dosimetry. Samples collected represented a full shift time weighted averages, spanning both the 1st and 2nd shifts. A total of 147 sound level meter measurements were also collected throughout the assessment simultaneously with the personal noise dosimetry. Data analysis of noise monitoring samples indicated the presence of a possible noise overexposure for 3 employees of the company. In accordance with internal company policy and Washington state health and safety regulations, the findings from the noise assessment reinforced the continued inclusion of the over-exposed employees into the company's hearing conservation program. Noise reduction strategy recommendations included a combination of engineering and administrative controls, in addition to the company's use of a broad range of hearing protection devices.","abstract_html":"This report documents the findings, observations, and recommendations of the investigator&#x27;s noise assessment survey, performed at a northwest company fabrication building located in Washington State. The assessment was performed at the request of the company&#x27;s safety management staff and the fabrication building&#x27;s industrial hygienist between June 6 and July 22, 2014. The goal of the noise assessment was to determine the risk of employees developing noise-induced hearing loss from their work at the company; to update the company&#x27;s hearing conservation program; and to provide noise reduction recommendations. During the assessment, noise monitoring data was collected through the use of personal noise dosimetry and through the use of a sound level meter. A total of 34 samples were collected from 32 employees using personal dosimetry. Samples collected represented a full shift time weighted averages, spanning both the 1st and 2nd shifts. A total of 147 sound level meter measurements were also collected throughout the assessment simultaneously with the personal noise dosimetry. Data analysis of noise monitoring samples indicated the presence of a possible noise overexposure for 3 employees of the company. In accordance with internal company policy and Washington state health and safety regulations, the findings from the noise assessment reinforced the continued inclusion of the over-exposed employees into the company&#x27;s hearing conservation program. Noise reduction strategy recommendations included a combination of engineering and administrative controls, in addition to the company&#x27;s use of a broad range of hearing protection devices.","abstract_has_math":false,"creators":["Thurdekoos, Amelia Rae"],"institution":null,"degree_name":"MS","degree_level":"Problem/Project Report","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:22:36Z","subjects":["Hearing","Conservation","Program Noise","Industrial Hygiene"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/3988"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/3988","href":"https://researchrepository.wvu.edu/etd/3988","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.3988","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.3988","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-5106","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Thurdekoos, Amelia Rae"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-01-01T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2016-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Problem/Project Report"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Hearing","Conservation","Program Noise","Industrial Hygiene"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.3988","https://researchrepository.wvu.edu/etd/3988"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This report documents the findings, observations, and recommendations of the investigator's noise assessment survey, performed at a northwest company fabrication building located in Washington State. The assessment was performed at the request of the company's safety management staff and the fabrication building's industrial hygienist between June 6 and July 22, 2014. The goal of the noise assessment was to determine the risk of employees developing noise-induced hearing loss from their work at the company; to update the company's hearing conservation program; and to provide noise reduction recommendations. During the assessment, noise monitoring data was collected through the use of personal noise dosimetry and through the use of a sound level meter. A total of 34 samples were collected from 32 employees using personal dosimetry. Samples collected represented a full shift time weighted averages, spanning both the 1st and 2nd shifts. A total of 147 sound level meter measurements were also collected throughout the assessment simultaneously with the personal noise dosimetry. Data analysis of noise monitoring samples indicated the presence of a possible noise overexposure for 3 employees of the company. In accordance with internal company policy and Washington state health and safety regulations, the findings from the noise assessment reinforced the continued inclusion of the over-exposed employees into the company's hearing conservation program. Noise reduction strategy recommendations included a combination of engineering and administrative controls, in addition to the company's use of a broad range of hearing protection devices."]},{"key":"dc:title","label":"Title","values":["Noise monitoring assessment of a northewest fabrication company."]}]}],"canonical_facts":{"dc:creator":["Thurdekoos, Amelia Rae"],"dc:date.available":["2021-01-01T08:00:00Z"],"dc:date.created":["2016-01-01T08:00:00Z"],"dc:description.abstract":["This report documents the findings, observations, and recommendations of the investigator's noise assessment survey, performed at a northwest company fabrication building located in Washington State. The assessment was performed at the request of the company's safety management staff and the fabrication building's industrial hygienist between June 6 and July 22, 2014. The goal of the noise assessment was to determine the risk of employees developing noise-induced hearing loss from their work at the company; to update the company's hearing conservation program; and to provide noise reduction recommendations. During the assessment, noise monitoring data was collected through the use of personal noise dosimetry and through the use of a sound level meter. A total of 34 samples were collected from 32 employees using personal dosimetry. Samples collected represented a full shift time weighted averages, spanning both the 1st and 2nd shifts. A total of 147 sound level meter measurements were also collected throughout the assessment simultaneously with the personal noise dosimetry. Data analysis of noise monitoring samples indicated the presence of a possible noise overexposure for 3 employees of the company. In accordance with internal company policy and Washington state health and safety regulations, the findings from the noise assessment reinforced the continued inclusion of the over-exposed employees into the company's hearing conservation program. Noise reduction strategy recommendations included a combination of engineering and administrative controls, in addition to the company's use of a broad range of hearing protection devices."],"dc:identifier":["https://doi.org/10.33915/etd.3988","https://researchrepository.wvu.edu/etd/3988"],"dc:subject":["Hearing","Conservation","Program Noise","Industrial Hygiene"],"dc:title":["Noise monitoring assessment of a northewest fabrication company."],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Problem/Project Report"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:22:36Z"}