{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-5358"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-5358","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Development of a separation riser with flow pulsations for small coal particles","abstract":"Removing sulfur before combustion is essential to lower the sulfur dioxide produced during combustion. Common separation processes have large obstacles including usage of large quantities of water, the need to dry the coal after separation, and additional environmental hazards created during the separation process. The current exploratory research concentrates on coal particles in the size range of 105< dp<210 microns. A small scale circulating fluidized bed was constructed with the addition of a gas pulsation generator. Various superficial gas velocities, u0, were used in conjunction with various rates of pulsations. The system was able to segregate dirtier coal from cleaner coal with various efficiencies for different flow conditions. The most favorable flow conditions were found to be: 1Hz flow pulsations and a superficial gas velocity of 0.8581ms-1 which reduced the mass percent sulfur of the initial sample of coal from 1.66% to 1.37%.","abstract_html":"Removing sulfur before combustion is essential to lower the sulfur dioxide produced during combustion. Common separation processes have large obstacles including usage of large quantities of water, the need to dry the coal after separation, and additional environmental hazards created during the separation process. The current exploratory research concentrates on coal particles in the size range of 105&lt; dp&lt;210 microns. A small scale circulating fluidized bed was constructed with the addition of a gas pulsation generator. Various superficial gas velocities, u0, were used in conjunction with various rates of pulsations. The system was able to segregate dirtier coal from cleaner coal with various efficiencies for different flow conditions. The most favorable flow conditions were found to be: 1Hz flow pulsations and a superficial gas velocity of 0.8581ms-1 which reduced the mass percent sulfur of the initial sample of coal from 1.66% to 1.37%.","abstract_has_math":false,"creators":["Musser, Jordan M. H."],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Mechanical and Aerospace Engineering","degree_department":null,"school":null,"contributors":[],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:17:37Z","subjects":["Mechanical engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/4321"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/4321","href":"https://researchrepository.wvu.edu/etd/4321","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.4321","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.4321","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-5358","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:creator","label":"Author","values":["Musser, Jordan M. H."]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2007-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical and Aerospace Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Mechanical engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.4321","https://researchrepository.wvu.edu/etd/4321"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Removing sulfur before combustion is essential to lower the sulfur dioxide produced during combustion. Common separation processes have large obstacles including usage of large quantities of water, the need to dry the coal after separation, and additional environmental hazards created during the separation process. The current exploratory research concentrates on coal particles in the size range of 105< dp<210 microns. A small scale circulating fluidized bed was constructed with the addition of a gas pulsation generator. Various superficial gas velocities, u0, were used in conjunction with various rates of pulsations. The system was able to segregate dirtier coal from cleaner coal with various efficiencies for different flow conditions. The most favorable flow conditions were found to be: 1Hz flow pulsations and a superficial gas velocity of 0.8581ms-1 which reduced the mass percent sulfur of the initial sample of coal from 1.66% to 1.37%."]},{"key":"dc:title","label":"Title","values":["Development of a separation riser with flow pulsations for small coal particles"]}]}],"canonical_facts":{"dc:creator":["Musser, Jordan M. H."],"dc:date.created":["2007-01-01T08:00:00Z"],"dc:description.abstract":["Removing sulfur before combustion is essential to lower the sulfur dioxide produced during combustion. Common separation processes have large obstacles including usage of large quantities of water, the need to dry the coal after separation, and additional environmental hazards created during the separation process. The current exploratory research concentrates on coal particles in the size range of 105< dp<210 microns. A small scale circulating fluidized bed was constructed with the addition of a gas pulsation generator. Various superficial gas velocities, u0, were used in conjunction with various rates of pulsations. The system was able to segregate dirtier coal from cleaner coal with various efficiencies for different flow conditions. The most favorable flow conditions were found to be: 1Hz flow pulsations and a superficial gas velocity of 0.8581ms-1 which reduced the mass percent sulfur of the initial sample of coal from 1.66% to 1.37%."],"dc:identifier":["https://doi.org/10.33915/etd.4321","https://researchrepository.wvu.edu/etd/4321"],"dc:subject":["Mechanical engineering"],"dc:title":["Development of a separation riser with flow pulsations for small coal particles"],"thesis:degree_discipline":["Mechanical and Aerospace Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:17:37Z"}