{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-6700"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-6700","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Dynamic calibration of drifting sensor arrays for real-time monitoring","abstract":"Traditional sensor calibration is restricted to mathematically relating the steady-state sensor responses to the target analyte concentrations to realize environment monitoring. However, commonly-used chemical sensors usually require a relatively long time, on the order of minutes, to reach steady-state operation, and exhibit nonlinear drifting behaviors. To achieve real-time monitoring of rapidly-changing environments while accommodating drifting behaviors, this work develops statistical methods for both forward descriptive calibration and inverse dynamic calibration of sensor arrays.;Forward calibration is performed based on experimental data. In this work, multivariate Gaussian processes (GPs) were adapted to obtain the forward calibration model, which quantifies the sensor response as a function of the analyte concentration, the drifting variables, and the sensors' exposure time. The multivariate GP method synergistically models all calibration data collected under a range of drifting conditions, and seeks to produce the calibration model of highest quality with the given experimental data. The forward calibration model is a descriptive model, relating sensors' time-dependent responses to a static environment specified by several variables, hence it is not able to assist in real-time monitoring of rapidly-changing environments.;To achieve real-time monitoring of analyte concentrations while fully utilizing the efficiency of forward calibration rendered by multivariate GPs, an inverse calibration method was developed. This inverse model takes the form of a transfer function regression, infers the time-varying analyte concentrations from the dynamic sensor responses, and thus can be coupled with sensors for real-time monitoring. The inverse transfer function model is estimated from the pseudo-calibration data generated by the forward multivariate GP model, which captures the sensors' dynamic and drifting behaviors as reflected in the real experimental data.;Simulated sensor arrays have been developed from real sensor data, and were used to demonstrate the calibration methods developed in this work.","abstract_html":"Traditional sensor calibration is restricted to mathematically relating the steady-state sensor responses to the target analyte concentrations to realize environment monitoring. However, commonly-used chemical sensors usually require a relatively long time, on the order of minutes, to reach steady-state operation, and exhibit nonlinear drifting behaviors. To achieve real-time monitoring of rapidly-changing environments while accommodating drifting behaviors, this work develops statistical methods for both forward descriptive calibration and inverse dynamic calibration of sensor arrays.;Forward calibration is performed based on experimental data. In this work, multivariate Gaussian processes (GPs) were adapted to obtain the forward calibration model, which quantifies the sensor response as a function of the analyte concentration, the drifting variables, and the sensors&#x27; exposure time. The multivariate GP method synergistically models all calibration data collected under a range of drifting conditions, and seeks to produce the calibration model of highest quality with the given experimental data. The forward calibration model is a descriptive model, relating sensors&#x27; time-dependent responses to a static environment specified by several variables, hence it is not able to assist in real-time monitoring of rapidly-changing environments.;To achieve real-time monitoring of analyte concentrations while fully utilizing the efficiency of forward calibration rendered by multivariate GPs, an inverse calibration method was developed. This inverse model takes the form of a transfer function regression, infers the time-varying analyte concentrations from the dynamic sensor responses, and thus can be coupled with sensors for real-time monitoring. The inverse transfer function model is estimated from the pseudo-calibration data generated by the forward multivariate GP model, which captures the sensors&#x27; dynamic and drifting behaviors as reflected in the real experimental data.;Simulated sensor arrays have been developed from real sensor data, and were used to demonstrate the calibration methods developed in this work.","abstract_has_math":false,"creators":["Geng, Zongyu"],"institution":null,"degree_name":"PhD","degree_level":"Dissertation","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":["Feng Yang","Wafik Iskander","Majid Jaridi","Natalia A Schmid","Nianqiang Wu"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:23:25Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/5659"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/5659","href":"https://researchrepository.wvu.edu/etd/5659","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.5659","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.5659","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-6700","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Feng Yang","Wafik Iskander","Majid Jaridi","Natalia A Schmid","Nianqiang Wu"]},{"key":"dc:creator","label":"Author","values":["Geng, Zongyu"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2015-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.5659","https://researchrepository.wvu.edu/etd/5659"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Traditional sensor calibration is restricted to mathematically relating the steady-state sensor responses to the target analyte concentrations to realize environment monitoring. However, commonly-used chemical sensors usually require a relatively long time, on the order of minutes, to reach steady-state operation, and exhibit nonlinear drifting behaviors. To achieve real-time monitoring of rapidly-changing environments while accommodating drifting behaviors, this work develops statistical methods for both forward descriptive calibration and inverse dynamic calibration of sensor arrays.;Forward calibration is performed based on experimental data. In this work, multivariate Gaussian processes (GPs) were adapted to obtain the forward calibration model, which quantifies the sensor response as a function of the analyte concentration, the drifting variables, and the sensors' exposure time. The multivariate GP method synergistically models all calibration data collected under a range of drifting conditions, and seeks to produce the calibration model of highest quality with the given experimental data. The forward calibration model is a descriptive model, relating sensors' time-dependent responses to a static environment specified by several variables, hence it is not able to assist in real-time monitoring of rapidly-changing environments.;To achieve real-time monitoring of analyte concentrations while fully utilizing the efficiency of forward calibration rendered by multivariate GPs, an inverse calibration method was developed. This inverse model takes the form of a transfer function regression, infers the time-varying analyte concentrations from the dynamic sensor responses, and thus can be coupled with sensors for real-time monitoring. The inverse transfer function model is estimated from the pseudo-calibration data generated by the forward multivariate GP model, which captures the sensors' dynamic and drifting behaviors as reflected in the real experimental data.;Simulated sensor arrays have been developed from real sensor data, and were used to demonstrate the calibration methods developed in this work."]},{"key":"dc:title","label":"Title","values":["Dynamic calibration of drifting sensor arrays for real-time monitoring"]}]}],"canonical_facts":{"dc:contributor":["Feng Yang","Wafik Iskander","Majid Jaridi","Natalia A Schmid","Nianqiang Wu"],"dc:creator":["Geng, Zongyu"],"dc:date.created":["2015-01-01T08:00:00Z"],"dc:description.abstract":["Traditional sensor calibration is restricted to mathematically relating the steady-state sensor responses to the target analyte concentrations to realize environment monitoring. However, commonly-used chemical sensors usually require a relatively long time, on the order of minutes, to reach steady-state operation, and exhibit nonlinear drifting behaviors. To achieve real-time monitoring of rapidly-changing environments while accommodating drifting behaviors, this work develops statistical methods for both forward descriptive calibration and inverse dynamic calibration of sensor arrays.;Forward calibration is performed based on experimental data. In this work, multivariate Gaussian processes (GPs) were adapted to obtain the forward calibration model, which quantifies the sensor response as a function of the analyte concentration, the drifting variables, and the sensors' exposure time. The multivariate GP method synergistically models all calibration data collected under a range of drifting conditions, and seeks to produce the calibration model of highest quality with the given experimental data. The forward calibration model is a descriptive model, relating sensors' time-dependent responses to a static environment specified by several variables, hence it is not able to assist in real-time monitoring of rapidly-changing environments.;To achieve real-time monitoring of analyte concentrations while fully utilizing the efficiency of forward calibration rendered by multivariate GPs, an inverse calibration method was developed. This inverse model takes the form of a transfer function regression, infers the time-varying analyte concentrations from the dynamic sensor responses, and thus can be coupled with sensors for real-time monitoring. The inverse transfer function model is estimated from the pseudo-calibration data generated by the forward multivariate GP model, which captures the sensors' dynamic and drifting behaviors as reflected in the real experimental data.;Simulated sensor arrays have been developed from real sensor data, and were used to demonstrate the calibration methods developed in this work."],"dc:identifier":["https://doi.org/10.33915/etd.5659","https://researchrepository.wvu.edu/etd/5659"],"dc:title":["Dynamic calibration of drifting sensor arrays for real-time monitoring"],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T09:23:25Z"}