{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-7771"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-7771","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Impact of the Nanopore Size on Estimation of Gas-in-Place for Marcellus Shale Gas Reservoirs","abstract":"Nanopores, pores less than 10 nanometers as defined for this study, have significant impact on the flow, production, and storage potential. These impacts, in turn, effect gas-in-place calculations and overall reservoir estimations.;This research studies a dry-gas reservoir in the Marcellus Shale. A dry-gas reservoir exhibits the same behavior as a wet gas reservoir under confinement effects of nanopores. Therefore, the published correlation for estimating the impact of nanopore size on the critical hydrocarbon properties are utilized in this study.;By use of the gas compositional analysis, the effects on the gas-in-place calculations of the confined pores were compared to the traditional reservoir calculations for unconfined pores. After applying the corrections to the critical temperature and pressure, the z-factor was found by the use of a z-factor chart. This z-factor was incorporated into the gas-in-place calculations and created an easily interpreted reservoir result in millions of cubic feet of gas.;Concluding the study, it was found that the gas-in-place calculations deviate by up to 8% when using confined pores versus unconfined pores. The pore sizes of 2nm, 4nm, and 5nm changed the gas-in-place calculation by -8%, 2% and 6% respectively when compared to the unconfined pore size range of 10nm-100nm. The actual field data for the calculations created a simple comparison of gas-in-place calculations of 2nm, 4nm, 5nm, and >10nm pore sizes, yielding 2 MMCF, 2.2 MMCF, 2.3 MMCF and 2.16 MMCF of gas-in-place per acre foot.","abstract_html":"Nanopores, pores less than 10 nanometers as defined for this study, have significant impact on the flow, production, and storage potential. These impacts, in turn, effect gas-in-place calculations and overall reservoir estimations.;This research studies a dry-gas reservoir in the Marcellus Shale. A dry-gas reservoir exhibits the same behavior as a wet gas reservoir under confinement effects of nanopores. Therefore, the published correlation for estimating the impact of nanopore size on the critical hydrocarbon properties are utilized in this study.;By use of the gas compositional analysis, the effects on the gas-in-place calculations of the confined pores were compared to the traditional reservoir calculations for unconfined pores. After applying the corrections to the critical temperature and pressure, the z-factor was found by the use of a z-factor chart. This z-factor was incorporated into the gas-in-place calculations and created an easily interpreted reservoir result in millions of cubic feet of gas.;Concluding the study, it was found that the gas-in-place calculations deviate by up to 8% when using confined pores versus unconfined pores. The pore sizes of 2nm, 4nm, and 5nm changed the gas-in-place calculation by -8%, 2% and 6% respectively when compared to the unconfined pore size range of 10nm-100nm. The actual field data for the calculations created a simple comparison of gas-in-place calculations of 2nm, 4nm, 5nm, and &gt;10nm pore sizes, yielding 2 MMCF, 2.2 MMCF, 2.3 MMCF and 2.16 MMCF of gas-in-place per acre foot.","abstract_has_math":false,"creators":["Stockdale, Alexandra Power"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Petroleum and Natural Gas Engineering","degree_department":null,"school":null,"contributors":["Kashy Aminian","Samuel Ameri","Keith Heasley"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:24:35Z","subjects":[],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/6730"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/6730","href":"https://researchrepository.wvu.edu/etd/6730","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.6730","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.6730","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-7771","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Kashy Aminian","Samuel Ameri","Keith Heasley"]},{"key":"dc:creator","label":"Author","values":["Stockdale, Alexandra Power"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.created","label":"Dc Date Created","values":["2015-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Petroleum and Natural Gas Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.6730","https://researchrepository.wvu.edu/etd/6730"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Nanopores, pores less than 10 nanometers as defined for this study, have significant impact on the flow, production, and storage potential. These impacts, in turn, effect gas-in-place calculations and overall reservoir estimations.;This research studies a dry-gas reservoir in the Marcellus Shale. A dry-gas reservoir exhibits the same behavior as a wet gas reservoir under confinement effects of nanopores. Therefore, the published correlation for estimating the impact of nanopore size on the critical hydrocarbon properties are utilized in this study.;By use of the gas compositional analysis, the effects on the gas-in-place calculations of the confined pores were compared to the traditional reservoir calculations for unconfined pores. After applying the corrections to the critical temperature and pressure, the z-factor was found by the use of a z-factor chart. This z-factor was incorporated into the gas-in-place calculations and created an easily interpreted reservoir result in millions of cubic feet of gas.;Concluding the study, it was found that the gas-in-place calculations deviate by up to 8% when using confined pores versus unconfined pores. The pore sizes of 2nm, 4nm, and 5nm changed the gas-in-place calculation by -8%, 2% and 6% respectively when compared to the unconfined pore size range of 10nm-100nm. The actual field data for the calculations created a simple comparison of gas-in-place calculations of 2nm, 4nm, 5nm, and >10nm pore sizes, yielding 2 MMCF, 2.2 MMCF, 2.3 MMCF and 2.16 MMCF of gas-in-place per acre foot."]},{"key":"dc:title","label":"Title","values":["Impact of the Nanopore Size on Estimation of Gas-in-Place for Marcellus Shale Gas Reservoirs"]}]}],"canonical_facts":{"dc:contributor":["Kashy Aminian","Samuel Ameri","Keith Heasley"],"dc:creator":["Stockdale, Alexandra Power"],"dc:date.created":["2015-01-01T08:00:00Z"],"dc:description.abstract":["Nanopores, pores less than 10 nanometers as defined for this study, have significant impact on the flow, production, and storage potential. These impacts, in turn, effect gas-in-place calculations and overall reservoir estimations.;This research studies a dry-gas reservoir in the Marcellus Shale. A dry-gas reservoir exhibits the same behavior as a wet gas reservoir under confinement effects of nanopores. Therefore, the published correlation for estimating the impact of nanopore size on the critical hydrocarbon properties are utilized in this study.;By use of the gas compositional analysis, the effects on the gas-in-place calculations of the confined pores were compared to the traditional reservoir calculations for unconfined pores. After applying the corrections to the critical temperature and pressure, the z-factor was found by the use of a z-factor chart. This z-factor was incorporated into the gas-in-place calculations and created an easily interpreted reservoir result in millions of cubic feet of gas.;Concluding the study, it was found that the gas-in-place calculations deviate by up to 8% when using confined pores versus unconfined pores. The pore sizes of 2nm, 4nm, and 5nm changed the gas-in-place calculation by -8%, 2% and 6% respectively when compared to the unconfined pore size range of 10nm-100nm. The actual field data for the calculations created a simple comparison of gas-in-place calculations of 2nm, 4nm, 5nm, and >10nm pore sizes, yielding 2 MMCF, 2.2 MMCF, 2.3 MMCF and 2.16 MMCF of gas-in-place per acre foot."],"dc:identifier":["https://doi.org/10.33915/etd.6730","https://researchrepository.wvu.edu/etd/6730"],"dc:title":["Impact of the Nanopore Size on Estimation of Gas-in-Place for Marcellus Shale Gas Reservoirs"],"thesis:degree_discipline":["Petroleum and Natural Gas Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:24:35Z"}