{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-8452"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-8452","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Chemometric Calibration of Surface enchanced Raman Spectra for Quantitative Analysis","abstract":"Raman spectroscopy, recognized as a powerful analytical technique, has been widely employed in many fields especially in the detection of hazard material containing in food or water. However, multiplexed analyte quantification based on Raman spectra remains a challenge due to the difficulties in accurate and precise modeling of the relationship between multiple analyte concentrations and dense spectral data with noise. In this work, a statistical procedure was developed to efficiently generate high-quality calibration models quantifying the analyte concentrations versus spectra relationship. The resulting calibration models are able to provide estimated concentration ranges (which reflect both point and uncertainty estimates) for the analytes of interest in an unknown sample based on its observed Raman spectrum. The calibration procedure integrates three unique methodology components. (i) Stochastic kriging with time-series errors was adapted to model Raman spectra as a function on analyte concentrations. (ii) Built on the kriging modeling, bootstrap resampling methods were adapted to quantify the uncertainty of analyte concentration estimates. (iii) Based on the uncertainty quantification capability, a two-stage experimental design method was developed for efficient sampling: How to use a minimum amount of experimental effort to achieve calibration models with desired uncertainty of analyte estimates? Simulation studies were derived from laboratory experimental data, and used to demonstrate the efficiency of the calibration procedure over the methods.","abstract_html":"Raman spectroscopy, recognized as a powerful analytical technique, has been widely employed in many fields especially in the detection of hazard material containing in food or water. However, multiplexed analyte quantification based on Raman spectra remains a challenge due to the difficulties in accurate and precise modeling of the relationship between multiple analyte concentrations and dense spectral data with noise. In this work, a statistical procedure was developed to efficiently generate high-quality calibration models quantifying the analyte concentrations versus spectra relationship. The resulting calibration models are able to provide estimated concentration ranges (which reflect both point and uncertainty estimates) for the analytes of interest in an unknown sample based on its observed Raman spectrum. The calibration procedure integrates three unique methodology components. (i) Stochastic kriging with time-series errors was adapted to model Raman spectra as a function on analyte concentrations. (ii) Built on the kriging modeling, bootstrap resampling methods were adapted to quantify the uncertainty of analyte concentration estimates. (iii) Based on the uncertainty quantification capability, a two-stage experimental design method was developed for efficient sampling: How to use a minimum amount of experimental effort to achieve calibration models with desired uncertainty of analyte estimates? Simulation studies were derived from laboratory experimental data, and used to demonstrate the efficiency of the calibration procedure over the methods.","abstract_has_math":false,"creators":["Shi, Xiaofei"],"institution":null,"degree_name":"PhD","degree_level":"Dissertation","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":["Feng Yang","Nianqiang Wu","Bhaskaran Gopalakrishnan","Xinjian He"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:25:14Z","subjects":["Chemometrics","Kriging","Design of experiments","Inverse modeling","Uncertainty quantification","Operational Research"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/7443"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/7443","href":"https://researchrepository.wvu.edu/etd/7443","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.7443","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.7443","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-8452","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Feng Yang","Nianqiang Wu","Bhaskaran Gopalakrishnan","Xinjian He"]},{"key":"dc:creator","label":"Author","values":["Shi, Xiaofei"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-02T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Dissertation"]},{"key":"thesis:degree_name","label":"Degree Name","values":["PhD"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Chemometrics","Kriging","Design of experiments","Inverse modeling","Uncertainty quantification","Operational Research"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.7443","https://researchrepository.wvu.edu/etd/7443"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Raman spectroscopy, recognized as a powerful analytical technique, has been widely employed in many fields especially in the detection of hazard material containing in food or water. However, multiplexed analyte quantification based on Raman spectra remains a challenge due to the difficulties in accurate and precise modeling of the relationship between multiple analyte concentrations and dense spectral data with noise. In this work, a statistical procedure was developed to efficiently generate high-quality calibration models quantifying the analyte concentrations versus spectra relationship. The resulting calibration models are able to provide estimated concentration ranges (which reflect both point and uncertainty estimates) for the analytes of interest in an unknown sample based on its observed Raman spectrum. The calibration procedure integrates three unique methodology components. (i) Stochastic kriging with time-series errors was adapted to model Raman spectra as a function on analyte concentrations. (ii) Built on the kriging modeling, bootstrap resampling methods were adapted to quantify the uncertainty of analyte concentration estimates. (iii) Based on the uncertainty quantification capability, a two-stage experimental design method was developed for efficient sampling: How to use a minimum amount of experimental effort to achieve calibration models with desired uncertainty of analyte estimates? Simulation studies were derived from laboratory experimental data, and used to demonstrate the efficiency of the calibration procedure over the methods."]},{"key":"dc:title","label":"Title","values":["Chemometric Calibration of Surface enchanced Raman Spectra for Quantitative Analysis"]}]}],"canonical_facts":{"dc:contributor":["Feng Yang","Nianqiang Wu","Bhaskaran Gopalakrishnan","Xinjian He"],"dc:creator":["Shi, Xiaofei"],"dc:date.available":["2019-12-02T08:00:00Z"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["Raman spectroscopy, recognized as a powerful analytical technique, has been widely employed in many fields especially in the detection of hazard material containing in food or water. However, multiplexed analyte quantification based on Raman spectra remains a challenge due to the difficulties in accurate and precise modeling of the relationship between multiple analyte concentrations and dense spectral data with noise. In this work, a statistical procedure was developed to efficiently generate high-quality calibration models quantifying the analyte concentrations versus spectra relationship. The resulting calibration models are able to provide estimated concentration ranges (which reflect both point and uncertainty estimates) for the analytes of interest in an unknown sample based on its observed Raman spectrum. The calibration procedure integrates three unique methodology components. (i) Stochastic kriging with time-series errors was adapted to model Raman spectra as a function on analyte concentrations. (ii) Built on the kriging modeling, bootstrap resampling methods were adapted to quantify the uncertainty of analyte concentration estimates. (iii) Based on the uncertainty quantification capability, a two-stage experimental design method was developed for efficient sampling: How to use a minimum amount of experimental effort to achieve calibration models with desired uncertainty of analyte estimates? Simulation studies were derived from laboratory experimental data, and used to demonstrate the efficiency of the calibration procedure over the methods."],"dc:identifier":["https://doi.org/10.33915/etd.7443","https://researchrepository.wvu.edu/etd/7443"],"dc:subject":["Chemometrics","Kriging","Design of experiments","Inverse modeling","Uncertainty quantification","Operational Research"],"dc:title":["Chemometric Calibration of Surface enchanced Raman Spectra for Quantitative Analysis"],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Dissertation"],"thesis:degree_name":["PhD"]},"updated_at":"2026-11-19T09:25:14Z"}