{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-8486"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-8486","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Can Fitts' Throughput Be A Predictor Of Muscle Fatigue – A Study Based On Metacarpal Gloves?","abstract":"In this study, Fitts’ throughput was used to estimate throughput for metacarpal gloves. Fitts’ throughput combines speed and accuracy during target transfer/movement tasks into a single performance index. It was hypothesized that the throughput will be affected by the glove condition and it will exhibit a relationship with the physiological response of hand muscles and perceived exertions. Fifteen healthy participants (10 males, 5 females) were recruited for data collection. Each participant performed a series of target transfer tasks using four glove conditions: (1) a pigskin leather (glove 1); (2) a synthetic fiber glove (glove 2); (3) a goat-grain leather glove (glove 3); (4) bare hand. The physiological response of hand muscles was recorded during a separate gripping study. The participants performed 60-second static gripping tasks using each glove condition at force levels of 35% of their maximum gripping strength. Surface electromyography (SEMG) was used to record activation levels of four-hand muscles: (i) Flexor Digitorum Superficialis, (ii) Flexor Carpi Radialis, (iii) Extensor Carpi Radialis Longus, and (iv) Extensor Digitorum. Glove condition had a significant effect on throughput (p<0.05). The highest throughput was observed for bare hand (3.17 bits/s), followed by Glove 3 (2.44 bits/s). High throughput signifies high accuracy and low task completion time. Glove 2 and Glove 1 had a similar throughput of 2.34 bits/s. The lowest muscle activation was observed for bare hand (51%), followed by glove 1 (59%), glove 2 (60%) and glove 3 (64%). A drop in the median frequency of SEMG data, which is an indication of muscle fatigue was significantly affected by the glove condition (p<0.05). The lowest drop was observed for bare hand (9%), followed by glove 2 (17%), glove 1 (18%) and glove 3 (23%). A similar trend was also observed for perceived exertions. Overall, the results of this study indicate that during gloved exertions, a direct relationship exists between throughput and the physiological response of hand muscles. The Fitts’ throughput holds the potential to be used as a performance measure to evaluate and compare different types of gloves.","abstract_html":"In this study, Fitts’ throughput was used to estimate throughput for metacarpal gloves. Fitts’ throughput combines speed and accuracy during target transfer/movement tasks into a single performance index. It was hypothesized that the throughput will be affected by the glove condition and it will exhibit a relationship with the physiological response of hand muscles and perceived exertions. Fifteen healthy participants (10 males, 5 females) were recruited for data collection. Each participant performed a series of target transfer tasks using four glove conditions: (1) a pigskin leather (glove 1); (2) a synthetic fiber glove (glove 2); (3) a goat-grain leather glove (glove 3); (4) bare hand. The physiological response of hand muscles was recorded during a separate gripping study. The participants performed 60-second static gripping tasks using each glove condition at force levels of 35% of their maximum gripping strength. Surface electromyography (SEMG) was used to record activation levels of four-hand muscles: (i) Flexor Digitorum Superficialis, (ii) Flexor Carpi Radialis, (iii) Extensor Carpi Radialis Longus, and (iv) Extensor Digitorum. Glove condition had a significant effect on throughput (p&lt;0.05). The highest throughput was observed for bare hand (3.17 bits/s), followed by Glove 3 (2.44 bits/s). High throughput signifies high accuracy and low task completion time. Glove 2 and Glove 1 had a similar throughput of 2.34 bits/s. The lowest muscle activation was observed for bare hand (51%), followed by glove 1 (59%), glove 2 (60%) and glove 3 (64%). A drop in the median frequency of SEMG data, which is an indication of muscle fatigue was significantly affected by the glove condition (p&lt;0.05). The lowest drop was observed for bare hand (9%), followed by glove 2 (17%), glove 1 (18%) and glove 3 (23%). A similar trend was also observed for perceived exertions. Overall, the results of this study indicate that during gloved exertions, a direct relationship exists between throughput and the physiological response of hand muscles. The Fitts’ throughput holds the potential to be used as a performance measure to evaluate and compare different types of gloves.","abstract_has_math":false,"creators":["Sah, Sachin"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Industrial and Managements Systems Engineering","degree_department":null,"school":null,"contributors":["Ashish D. Nimbarte","Eduardo Sosa","Leily Farrokhvar"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:25:22Z","subjects":["Metacarpal Gloves; Fitt’s Law; Throughput; Muscle Activity","Ergonomics","Industrial Engineering"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/7409"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/7409","href":"https://researchrepository.wvu.edu/etd/7409","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.7409","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.7409","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-8486","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Ashish D. Nimbarte","Eduardo Sosa","Leily Farrokhvar"]},{"key":"dc:creator","label":"Author","values":["Sah, Sachin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2019-12-05T08:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2019-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Industrial and Managements Systems Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Metacarpal Gloves; Fitt’s Law; Throughput; Muscle Activity","Ergonomics","Industrial Engineering"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.7409","https://researchrepository.wvu.edu/etd/7409"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["In this study, Fitts’ throughput was used to estimate throughput for metacarpal gloves. Fitts’ throughput combines speed and accuracy during target transfer/movement tasks into a single performance index. It was hypothesized that the throughput will be affected by the glove condition and it will exhibit a relationship with the physiological response of hand muscles and perceived exertions. Fifteen healthy participants (10 males, 5 females) were recruited for data collection. Each participant performed a series of target transfer tasks using four glove conditions: (1) a pigskin leather (glove 1); (2) a synthetic fiber glove (glove 2); (3) a goat-grain leather glove (glove 3); (4) bare hand. The physiological response of hand muscles was recorded during a separate gripping study. The participants performed 60-second static gripping tasks using each glove condition at force levels of 35% of their maximum gripping strength. Surface electromyography (SEMG) was used to record activation levels of four-hand muscles: (i) Flexor Digitorum Superficialis, (ii) Flexor Carpi Radialis, (iii) Extensor Carpi Radialis Longus, and (iv) Extensor Digitorum. Glove condition had a significant effect on throughput (p<0.05). The highest throughput was observed for bare hand (3.17 bits/s), followed by Glove 3 (2.44 bits/s). High throughput signifies high accuracy and low task completion time. Glove 2 and Glove 1 had a similar throughput of 2.34 bits/s. The lowest muscle activation was observed for bare hand (51%), followed by glove 1 (59%), glove 2 (60%) and glove 3 (64%). A drop in the median frequency of SEMG data, which is an indication of muscle fatigue was significantly affected by the glove condition (p<0.05). The lowest drop was observed for bare hand (9%), followed by glove 2 (17%), glove 1 (18%) and glove 3 (23%). A similar trend was also observed for perceived exertions. Overall, the results of this study indicate that during gloved exertions, a direct relationship exists between throughput and the physiological response of hand muscles. The Fitts’ throughput holds the potential to be used as a performance measure to evaluate and compare different types of gloves."]},{"key":"dc:title","label":"Title","values":["Can Fitts' Throughput Be A Predictor Of Muscle Fatigue – A Study Based On Metacarpal Gloves?"]}]}],"canonical_facts":{"dc:contributor":["Ashish D. Nimbarte","Eduardo Sosa","Leily Farrokhvar"],"dc:creator":["Sah, Sachin"],"dc:date.available":["2019-12-05T08:00:00Z"],"dc:date.created":["2019-01-01T08:00:00Z"],"dc:description.abstract":["In this study, Fitts’ throughput was used to estimate throughput for metacarpal gloves. Fitts’ throughput combines speed and accuracy during target transfer/movement tasks into a single performance index. It was hypothesized that the throughput will be affected by the glove condition and it will exhibit a relationship with the physiological response of hand muscles and perceived exertions. Fifteen healthy participants (10 males, 5 females) were recruited for data collection. Each participant performed a series of target transfer tasks using four glove conditions: (1) a pigskin leather (glove 1); (2) a synthetic fiber glove (glove 2); (3) a goat-grain leather glove (glove 3); (4) bare hand. The physiological response of hand muscles was recorded during a separate gripping study. The participants performed 60-second static gripping tasks using each glove condition at force levels of 35% of their maximum gripping strength. Surface electromyography (SEMG) was used to record activation levels of four-hand muscles: (i) Flexor Digitorum Superficialis, (ii) Flexor Carpi Radialis, (iii) Extensor Carpi Radialis Longus, and (iv) Extensor Digitorum. Glove condition had a significant effect on throughput (p<0.05). The highest throughput was observed for bare hand (3.17 bits/s), followed by Glove 3 (2.44 bits/s). High throughput signifies high accuracy and low task completion time. Glove 2 and Glove 1 had a similar throughput of 2.34 bits/s. The lowest muscle activation was observed for bare hand (51%), followed by glove 1 (59%), glove 2 (60%) and glove 3 (64%). A drop in the median frequency of SEMG data, which is an indication of muscle fatigue was significantly affected by the glove condition (p<0.05). The lowest drop was observed for bare hand (9%), followed by glove 2 (17%), glove 1 (18%) and glove 3 (23%). A similar trend was also observed for perceived exertions. Overall, the results of this study indicate that during gloved exertions, a direct relationship exists between throughput and the physiological response of hand muscles. The Fitts’ throughput holds the potential to be used as a performance measure to evaluate and compare different types of gloves."],"dc:identifier":["https://doi.org/10.33915/etd.7409","https://researchrepository.wvu.edu/etd/7409"],"dc:subject":["Metacarpal Gloves; Fitt’s Law; Throughput; Muscle Activity","Ergonomics","Industrial Engineering"],"dc:title":["Can Fitts' Throughput Be A Predictor Of Muscle Fatigue – A Study Based On Metacarpal Gloves?"],"thesis:degree_discipline":["Industrial and Managements Systems Engineering"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:25:22Z"}