{"id":{"repo_id":"wvu","oai_identifier":"oai:researchrepository.wvu.edu:etd-9020"},"canonical_url":"https://search.ndltd.org/etd/wvu/oai:researchrepository.wvu.edu:etd-9020","repository":{"repo_id":"wvu","name":"West Virginia University","base_url":"https://researchrepository.wvu.edu/do/oai/"},"display":{"title":"Effect of Pad Design and Bracket Manufacturing Method on Bracket Bond Strength","abstract":"Objective: The objective is to determine if there is a significant difference in shear bond strength and debonding characteristics between one-piece metal brackets made by metal injection molding (MIM) and multi-piece metal brackets made by machining then soldering/brazing with differing pad designs. Methods: A total of thirteen metal orthodontic brackets manufactured by 8 different companies were divided into two groups: one-piece MIM and multi-piece brackets. Each group consisted of 10 brackets for a total of 130 brackets. Brackets were bonded to stainless steel tubes with a universal bonding technique. Samples were tested on the universal Instron testing machine to measure the shear bond strength. Force required to debond each bracket was recorded. Brackets were observed after debond and an ARI score assigned. Data were analyzed using a two sample t-test. Results: The mean shear bond strength and ARI scores for the entire study sample were 3.7±1.7 and 4.2±0.7, respectively. The results of two sample t test showed that there was no significant difference between the one-piece MIM brackets (3.5±1.7) and the multi-piece brackets (4.0±1.8) in mean shear bond strength (t(128)=1.33, p=0.18). But the mean of ARI scores of the multi-piece brackets (4.4±0.7) was significantly higher than the one-piece MIM brackets (4.0±0.7) (t(128)=3.5, p=0.006). Conclusion: One-piece metal orthodontic brackets manufactured by MIM and multi-piece brackets manufactured by machining then soldering/brazing exhibit similar shear bond strengths. However, one-piece brackets showed a significantly lower ARI score than multi-piece brackets, indicating a higher percentage of adhesive left on the one-piece bracket surface after debond.","abstract_html":"Objective: The objective is to determine if there is a significant difference in shear bond strength and debonding characteristics between one-piece metal brackets made by metal injection molding (MIM) and multi-piece metal brackets made by machining then soldering/brazing with differing pad designs. Methods: A total of thirteen metal orthodontic brackets manufactured by 8 different companies were divided into two groups: one-piece MIM and multi-piece brackets. Each group consisted of 10 brackets for a total of 130 brackets. Brackets were bonded to stainless steel tubes with a universal bonding technique. Samples were tested on the universal Instron testing machine to measure the shear bond strength. Force required to debond each bracket was recorded. Brackets were observed after debond and an ARI score assigned. Data were analyzed using a two sample t-test. Results: The mean shear bond strength and ARI scores for the entire study sample were 3.7±1.7 and 4.2±0.7, respectively. The results of two sample t test showed that there was no significant difference between the one-piece MIM brackets (3.5±1.7) and the multi-piece brackets (4.0±1.8) in mean shear bond strength (t(128)=1.33, p=0.18). But the mean of ARI scores of the multi-piece brackets (4.4±0.7) was significantly higher than the one-piece MIM brackets (4.0±0.7) (t(128)=3.5, p=0.006). Conclusion: One-piece metal orthodontic brackets manufactured by MIM and multi-piece brackets manufactured by machining then soldering/brazing exhibit similar shear bond strengths. However, one-piece brackets showed a significantly lower ARI score than multi-piece brackets, indicating a higher percentage of adhesive left on the one-piece bracket surface after debond.","abstract_has_math":false,"creators":["Osborne, Dustin"],"institution":null,"degree_name":"MS","degree_level":"Thesis","degree_discipline":"Orthodontics","degree_department":null,"school":null,"contributors":["Chris Martin","Peter Ngan","Susan Morgan"],"advisors":[],"committee_chairs":[],"committee_members":[],"year":null,"date_issued":"","date_published":null,"updated_at":"2026-11-19T09:26:05Z","subjects":["SBS","MIM","ARI","milled","brazed","soldered","base","Orthodontics and Orthodontology"],"languages":[],"rights":[],"rights_urls":[],"identifier_entries":[{"key":"dc:identifier","label":"Identifier","values":["https://researchrepository.wvu.edu/etd/8130"],"render_values":[{"text":"https://researchrepository.wvu.edu/etd/8130","href":"https://researchrepository.wvu.edu/etd/8130","code":true}]}],"person_identifier_entries":[]},"links":{"outbound_url":"https://doi.org/10.33915/etd.8130","outbound_label":"DOI","outbound_source":"dc:identifier","record_url":"https://doi.org/10.33915/etd.8130","record_label":"Repository record","record_kind":"doi","record_source":"dc:identifier","download_url":null,"download_label":null,"download_source":null,"access_status":null,"embargo_until":null,"access_note":null},"source_record":{"url":"https://researchrepository.wvu.edu/do/oai/?verb=GetRecord&metadataPrefix=oai_etdms&identifier=oai%3Aresearchrepository.wvu.edu%3Aetd-9020","prefix":"oai_etdms"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor","label":"Contributor","values":["Chris Martin","Peter Ngan","Susan Morgan"]},{"key":"dc:creator","label":"Author","values":["Osborne, Dustin"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.available","label":"Dc Date Available","values":["2021-04-12T07:00:00Z"]},{"key":"dc:date.created","label":"Dc Date Created","values":["2021-01-01T08:00:00Z"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Orthodontics"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Thesis"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MS"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["SBS","MIM","ARI","milled","brazed","soldered","base","Orthodontics and Orthodontology"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier","label":"Identifier","values":["https://doi.org/10.33915/etd.8130","https://researchrepository.wvu.edu/etd/8130"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Objective: The objective is to determine if there is a significant difference in shear bond strength and debonding characteristics between one-piece metal brackets made by metal injection molding (MIM) and multi-piece metal brackets made by machining then soldering/brazing with differing pad designs. Methods: A total of thirteen metal orthodontic brackets manufactured by 8 different companies were divided into two groups: one-piece MIM and multi-piece brackets. Each group consisted of 10 brackets for a total of 130 brackets. Brackets were bonded to stainless steel tubes with a universal bonding technique. Samples were tested on the universal Instron testing machine to measure the shear bond strength. Force required to debond each bracket was recorded. Brackets were observed after debond and an ARI score assigned. Data were analyzed using a two sample t-test. Results: The mean shear bond strength and ARI scores for the entire study sample were 3.7±1.7 and 4.2±0.7, respectively. The results of two sample t test showed that there was no significant difference between the one-piece MIM brackets (3.5±1.7) and the multi-piece brackets (4.0±1.8) in mean shear bond strength (t(128)=1.33, p=0.18). But the mean of ARI scores of the multi-piece brackets (4.4±0.7) was significantly higher than the one-piece MIM brackets (4.0±0.7) (t(128)=3.5, p=0.006). Conclusion: One-piece metal orthodontic brackets manufactured by MIM and multi-piece brackets manufactured by machining then soldering/brazing exhibit similar shear bond strengths. However, one-piece brackets showed a significantly lower ARI score than multi-piece brackets, indicating a higher percentage of adhesive left on the one-piece bracket surface after debond."]},{"key":"dc:title","label":"Title","values":["Effect of Pad Design and Bracket Manufacturing Method on Bracket Bond Strength"]}]}],"canonical_facts":{"dc:contributor":["Chris Martin","Peter Ngan","Susan Morgan"],"dc:creator":["Osborne, Dustin"],"dc:date.available":["2021-04-12T07:00:00Z"],"dc:date.created":["2021-01-01T08:00:00Z"],"dc:description.abstract":["Objective: The objective is to determine if there is a significant difference in shear bond strength and debonding characteristics between one-piece metal brackets made by metal injection molding (MIM) and multi-piece metal brackets made by machining then soldering/brazing with differing pad designs. Methods: A total of thirteen metal orthodontic brackets manufactured by 8 different companies were divided into two groups: one-piece MIM and multi-piece brackets. Each group consisted of 10 brackets for a total of 130 brackets. Brackets were bonded to stainless steel tubes with a universal bonding technique. Samples were tested on the universal Instron testing machine to measure the shear bond strength. Force required to debond each bracket was recorded. Brackets were observed after debond and an ARI score assigned. Data were analyzed using a two sample t-test. Results: The mean shear bond strength and ARI scores for the entire study sample were 3.7±1.7 and 4.2±0.7, respectively. The results of two sample t test showed that there was no significant difference between the one-piece MIM brackets (3.5±1.7) and the multi-piece brackets (4.0±1.8) in mean shear bond strength (t(128)=1.33, p=0.18). But the mean of ARI scores of the multi-piece brackets (4.4±0.7) was significantly higher than the one-piece MIM brackets (4.0±0.7) (t(128)=3.5, p=0.006). Conclusion: One-piece metal orthodontic brackets manufactured by MIM and multi-piece brackets manufactured by machining then soldering/brazing exhibit similar shear bond strengths. However, one-piece brackets showed a significantly lower ARI score than multi-piece brackets, indicating a higher percentage of adhesive left on the one-piece bracket surface after debond."],"dc:identifier":["https://doi.org/10.33915/etd.8130","https://researchrepository.wvu.edu/etd/8130"],"dc:subject":["SBS","MIM","ARI","milled","brazed","soldered","base","Orthodontics and Orthodontology"],"dc:title":["Effect of Pad Design and Bracket Manufacturing Method on Bracket Bond Strength"],"thesis:degree_discipline":["Orthodontics"],"thesis:degree_level":["Thesis"],"thesis:degree_name":["MS"]},"updated_at":"2026-11-19T09:26:05Z"}