{"id":{"repo_id":"york","oai_identifier":"oai:yorkspace.library.yorku.ca:10315/36775"},"canonical_url":"https://search.ndltd.org/etd/york/oai:yorkspace.library.yorku.ca:10315/36775","repository":{"repo_id":"york","name":"York University","base_url":"https://yorkspace.library.yorku.ca/oai/request"},"display":{"title":"Assessing the Use of Ultrasound to Quantify Spine Kinematics","abstract":"This thesis described the use of ultrasound in measuring multiplanar in-vivo lumbar spine motion in various positions of flexion and axial rotation using two separate ultrasound-based methods and was compared to surface-based optoelectronic motion capture. 14 instances of outlier range of motion were detected with the sagittal imaging method and complex movement sequences were uncovered with the transverse imaging method. Two error metrics were described and evaluated: (1) repeatability, which described the likeness of repeated images and subsequent image analysis; (2) robustness, which described the tolerance of the ultrasound measurement system to systematically induced error. The sagittal imaging method was considered robust and repeatable however the transverse method was less repeatable, with error potentially resulting from soft tissue creep. This thesis demonstrated that it is possible to measure multiplanar intervertebral motion via US and may help identify risky movement sequences which may appear normal in a surface-based motion capture investigation.","abstract_html":"This thesis described the use of ultrasound in measuring multiplanar in-vivo lumbar spine motion in various positions of flexion and axial rotation using two separate ultrasound-based methods and was compared to surface-based optoelectronic motion capture. 14 instances of outlier range of motion were detected with the sagittal imaging method and complex movement sequences were uncovered with the transverse imaging method. Two error metrics were described and evaluated: (1) repeatability, which described the likeness of repeated images and subsequent image analysis; (2) robustness, which described the tolerance of the ultrasound measurement system to systematically induced error. The sagittal imaging method was considered robust and repeatable however the transverse method was less repeatable, with error potentially resulting from soft tissue creep. This thesis demonstrated that it is possible to measure multiplanar intervertebral motion via US and may help identify risky movement sequences which may appear normal in a surface-based motion capture investigation.","abstract_has_math":false,"creators":["Desroches, Daniel Alain"],"institution":null,"degree_name":"MSc - Master of Science","degree_level":"Master's","degree_discipline":"Kinesiology & Health Science","degree_department":null,"school":null,"contributors":[],"advisors":["Drake, Janessa D. M."],"committee_chairs":[],"committee_members":[],"year":2019,"date_issued":"2019-11-22","date_published":"2019-11-22","updated_at":"2026-11-19T09:44:31Z","subjects":["Health sciences"],"languages":["en"],"rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10315/36775","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10315/36775","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ayork%3Aoai%3Ayorkspace.library.yorku.ca%3A10315%2F36775","prefix":"oai_dc"},"source_record":{"url":"https://yorkspace.library.yorku.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Ayorkspace.library.yorku.ca%3A10315%2F36775","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Drake, Janessa D. M."]},{"key":"dc:creator","label":"Author","values":["Desroches, Daniel Alain"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2019-11-22T18:54:30Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2019-11-22T18:54:30Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2019-07"]},{"key":"dc:date.issued","label":"Date","values":["2019-11-22"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2019-11-22T18:54:30Z"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Kinesiology & Health Science"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MSc - Master of Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Health sciences"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Biomechanics","Spine","Health","Mechanics","Kinesiology","Lumbar","Intervertebral","Kinematics"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10315/36775"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["This thesis described the use of ultrasound in measuring multiplanar in-vivo lumbar spine motion in various positions of flexion and axial rotation using two separate ultrasound-based methods and was compared to surface-based optoelectronic motion capture. 14 instances of outlier range of motion were detected with the sagittal imaging method and complex movement sequences were uncovered with the transverse imaging method. Two error metrics were described and evaluated: (1) repeatability, which described the likeness of repeated images and subsequent image analysis; (2) robustness, which described the tolerance of the ultrasound measurement system to systematically induced error. The sagittal imaging method was considered robust and repeatable however the transverse method was less repeatable, with error potentially resulting from soft tissue creep. This thesis demonstrated that it is possible to measure multiplanar intervertebral motion via US and may help identify risky movement sequences which may appear normal in a surface-based motion capture investigation."]},{"key":"dc:title","label":"Title","values":["Assessing the Use of Ultrasound to Quantify Spine Kinematics"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Drake, Janessa D. M."],"dc:creator":["Desroches, Daniel Alain"],"dc:date.accessioned":["2019-11-22T18:54:30Z"],"dc:date.available":["2019-11-22T18:54:30Z"],"dc:date.copyright":["2019-07"],"dc:date.issued":["2019-11-22"],"dc:date.updated":["2019-11-22T18:54:30Z"],"dc:description.abstract":["This thesis described the use of ultrasound in measuring multiplanar in-vivo lumbar spine motion in various positions of flexion and axial rotation using two separate ultrasound-based methods and was compared to surface-based optoelectronic motion capture. 14 instances of outlier range of motion were detected with the sagittal imaging method and complex movement sequences were uncovered with the transverse imaging method. Two error metrics were described and evaluated: (1) repeatability, which described the likeness of repeated images and subsequent image analysis; (2) robustness, which described the tolerance of the ultrasound measurement system to systematically induced error. The sagittal imaging method was considered robust and repeatable however the transverse method was less repeatable, with error potentially resulting from soft tissue creep. This thesis demonstrated that it is possible to measure multiplanar intervertebral motion via US and may help identify risky movement sequences which may appear normal in a surface-based motion capture investigation."],"dc:identifier.uri":["http://hdl.handle.net/10315/36775"],"dc:language":["en"],"dc:rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"dc:subject":["Health sciences"],"dc:subject.keyword":["Biomechanics","Spine","Health","Mechanics","Kinesiology","Lumbar","Intervertebral","Kinematics"],"dc:title":["Assessing the Use of Ultrasound to Quantify Spine Kinematics"],"dc:type":["Electronic Thesis or Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Kinesiology & Health Science"],"thesis:degree_level":["Master's"],"thesis:degree_name":["MSc - Master of Science"]},"updated_at":"2026-11-19T09:44:31Z"}