{"id":{"repo_id":"york","oai_identifier":"oai:yorkspace.library.yorku.ca:10315/37894"},"canonical_url":"https://search.ndltd.org/etd/york/oai:yorkspace.library.yorku.ca:10315/37894","repository":{"repo_id":"york","name":"York University","base_url":"https://yorkspace.library.yorku.ca/oai/request"},"display":{"title":"Thermal Performance of Unloaded Spiral Strand and Locked-Coil Cables for Bridge Infrastructure","abstract":"There are no contemporary code requirements for the fire resistance of bridge infrastructure, nor is there guidance available for practitioners who wish to design cable-supported structures for fire. This research seeks to develop an understanding of the thermal response of steel stay-cables under exposure to a pool fire. Multiple varieties of stay-cable are instrumented with thermocouples and heated by a methanol pool fire. Novel imaging techniques observe the cables surface during heating and cooling and enable the calculation of thermal strains and deformations. Results show a normalization of cross-sectional temperatures outside of the localized heating region for cable diameters up to 140 mm, provide comparisons of heat transfer behaviours for different cable sizes and configurations, present a novel thermal rotational effect, and calculate cable thermal expansion values. Predictive thermal expansion values provided by the Eurocode were shown to underpredict cable thermal expansion in most cases.","abstract_html":"There are no contemporary code requirements for the fire resistance of bridge infrastructure, nor is there guidance available for practitioners who wish to design cable-supported structures for fire. This research seeks to develop an understanding of the thermal response of steel stay-cables under exposure to a pool fire. Multiple varieties of stay-cable are instrumented with thermocouples and heated by a methanol pool fire. Novel imaging techniques observe the cables surface during heating and cooling and enable the calculation of thermal strains and deformations. Results show a normalization of cross-sectional temperatures outside of the localized heating region for cable diameters up to 140 mm, provide comparisons of heat transfer behaviours for different cable sizes and configurations, present a novel thermal rotational effect, and calculate cable thermal expansion values. Predictive thermal expansion values provided by the Eurocode were shown to underpredict cable thermal expansion in most cases.","abstract_has_math":false,"creators":["Nicoletta, Benjamin Justin Salvatore"],"institution":null,"degree_name":"MASc - Master of Applied Science","degree_level":"Master's","degree_discipline":"Civil Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Gales, John A."],"committee_chairs":[],"committee_members":[],"year":2020,"date_issued":"2020-11-13","date_published":"2020-11-13","updated_at":"2026-11-19T09:47:30Z","subjects":["Civil engineering"],"languages":["en"],"rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10315/37894","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10315/37894","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ayork%3Aoai%3Ayorkspace.library.yorku.ca%3A10315%2F37894","prefix":"oai_dc"},"source_record":{"url":"https://yorkspace.library.yorku.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Ayorkspace.library.yorku.ca%3A10315%2F37894","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Gales, John A."]},{"key":"dc:creator","label":"Author","values":["Nicoletta, Benjamin Justin Salvatore"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2020-11-13T13:48:11Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2020-11-13T13:48:11Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2020-08"]},{"key":"dc:date.issued","label":"Date","values":["2020-11-13"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2020-11-13T13:48:11Z"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Civil Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MASc - Master of Applied Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Civil engineering"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Bridges","Bridge fire","Cables","Tension member","Steel","Fire","Thermal performance","Cable-supported","Structure fire","Pool fire","Digital image correlation","Narrow-spectrum illumination","Structural engineering","Bridge engineering","Fire safety","Fire safety engineering"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10315/37894"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["There are no contemporary code requirements for the fire resistance of bridge infrastructure, nor is there guidance available for practitioners who wish to design cable-supported structures for fire. This research seeks to develop an understanding of the thermal response of steel stay-cables under exposure to a pool fire. Multiple varieties of stay-cable are instrumented with thermocouples and heated by a methanol pool fire. Novel imaging techniques observe the cables surface during heating and cooling and enable the calculation of thermal strains and deformations. Results show a normalization of cross-sectional temperatures outside of the localized heating region for cable diameters up to 140 mm, provide comparisons of heat transfer behaviours for different cable sizes and configurations, present a novel thermal rotational effect, and calculate cable thermal expansion values. Predictive thermal expansion values provided by the Eurocode were shown to underpredict cable thermal expansion in most cases."]},{"key":"dc:title","label":"Title","values":["Thermal Performance of Unloaded Spiral Strand and Locked-Coil Cables for Bridge Infrastructure"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Gales, John A."],"dc:creator":["Nicoletta, Benjamin Justin Salvatore"],"dc:date.accessioned":["2020-11-13T13:48:11Z"],"dc:date.available":["2020-11-13T13:48:11Z"],"dc:date.copyright":["2020-08"],"dc:date.issued":["2020-11-13"],"dc:date.updated":["2020-11-13T13:48:11Z"],"dc:description.abstract":["There are no contemporary code requirements for the fire resistance of bridge infrastructure, nor is there guidance available for practitioners who wish to design cable-supported structures for fire. This research seeks to develop an understanding of the thermal response of steel stay-cables under exposure to a pool fire. Multiple varieties of stay-cable are instrumented with thermocouples and heated by a methanol pool fire. Novel imaging techniques observe the cables surface during heating and cooling and enable the calculation of thermal strains and deformations. Results show a normalization of cross-sectional temperatures outside of the localized heating region for cable diameters up to 140 mm, provide comparisons of heat transfer behaviours for different cable sizes and configurations, present a novel thermal rotational effect, and calculate cable thermal expansion values. Predictive thermal expansion values provided by the Eurocode were shown to underpredict cable thermal expansion in most cases."],"dc:identifier.uri":["http://hdl.handle.net/10315/37894"],"dc:language":["en"],"dc:rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"dc:subject":["Civil engineering"],"dc:subject.keyword":["Bridges","Bridge fire","Cables","Tension member","Steel","Fire","Thermal performance","Cable-supported","Structure fire","Pool fire","Digital image correlation","Narrow-spectrum illumination","Structural engineering","Bridge engineering","Fire safety","Fire safety engineering"],"dc:title":["Thermal Performance of Unloaded Spiral Strand and Locked-Coil Cables for Bridge Infrastructure"],"dc:type":["Electronic Thesis or Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Civil Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["MASc - Master of Applied Science"]},"updated_at":"2026-11-19T09:47:30Z"}