{"id":{"repo_id":"york","oai_identifier":"oai:yorkspace.library.yorku.ca:10315/43835"},"canonical_url":"https://search.ndltd.org/etd/york/oai:yorkspace.library.yorku.ca:10315/43835","repository":{"repo_id":"york","name":"York University","base_url":"https://yorkspace.library.yorku.ca/oai/request"},"display":{"title":"Fluorometric Detection of Multiple Bacteria in Water Using Cell Imprinted Polymer Thin Films Integrated into a Microfluidic Channel","abstract":"Waterborne pathogens threaten public health, but standard detection methods—culture plating and molecular assays—are slow, laborious, and confined to centralized labs. Biosensors promise rapid, on-site monitoring, yet antibody-based designs demand cold-chain handling and are fragile. This thesis introduces a fluorescence microfluidic sensor built on whole-cell imprinted polymers (CIPs), offering a robust, reagent-free alternative for duplex detection in water. CIP thin films were formed in situ within microchannels by polymerizing around target bacterial cells, creating selective cavities. Multiple CIP regions on a single chip enable parallel capture of different species. After trapping cells, optimized FITC injection generates a fluorescence signal proportional to bacterial concentration. In singleplex tests with Salmonella, the sensor achieved a limit of detection (LOD) of 1.47 × 10³ CFU/mL, a limit of quantification (LOQ) of 5.28 × 10³ CFU/mL, and a linear response from 10³ to 10⁷ CFU/mL. Selectivity assays showed preferential Salmonella binding over non-targets. Duplex mode captured both Salmonella and E. coli concurrently at concentrations above 10⁵ CFU/mL. Although multiplexing reduced sensitivity, the CIP-based sensor requires minimal sample volume, no complex prep, and avoids cold storage, underscoring its field-ready potential. Future work will focus on polymer optimization, signal amplification, and validation with real environmental samples.","abstract_html":"Waterborne pathogens threaten public health, but standard detection methods—culture plating and molecular assays—are slow, laborious, and confined to centralized labs. Biosensors promise rapid, on-site monitoring, yet antibody-based designs demand cold-chain handling and are fragile. This thesis introduces a fluorescence microfluidic sensor built on whole-cell imprinted polymers (CIPs), offering a robust, reagent-free alternative for duplex detection in water. CIP thin films were formed in situ within microchannels by polymerizing around target bacterial cells, creating selective cavities. Multiple CIP regions on a single chip enable parallel capture of different species. After trapping cells, optimized FITC injection generates a fluorescence signal proportional to bacterial concentration. In singleplex tests with Salmonella, the sensor achieved a limit of detection (LOD) of 1.47 × 10³ CFU/mL, a limit of quantification (LOQ) of 5.28 × 10³ CFU/mL, and a linear response from 10³ to 10⁷ CFU/mL. Selectivity assays showed preferential Salmonella binding over non-targets. Duplex mode captured both Salmonella and E. coli concurrently at concentrations above 10⁵ CFU/mL. Although multiplexing reduced sensitivity, the CIP-based sensor requires minimal sample volume, no complex prep, and avoids cold storage, underscoring its field-ready potential. Future work will focus on polymer optimization, signal amplification, and validation with real environmental samples.","abstract_has_math":false,"creators":["Mahmoud, Islam"],"institution":null,"degree_name":"MASc - Master of Applied Science","degree_level":"Master's","degree_discipline":"Mechanical Engineering","degree_department":null,"school":null,"contributors":[],"advisors":["Rezai, Pouya"],"committee_chairs":[],"committee_members":[],"year":2026,"date_issued":"2026-07-24","date_published":"2026-07-24","updated_at":"2026-11-19T09:47:00Z","subjects":["Biomedical engineering","Environmental engineering","Mechanical engineering"],"languages":["en"],"rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"rights_urls":[],"identifier_entries":[],"person_identifier_entries":[]},"links":{"outbound_url":"https://hdl.handle.net/10315/43835","outbound_label":"Handle","outbound_source":"dc:identifier.uri","record_url":"https://hdl.handle.net/10315/43835","record_label":"Repository record","record_kind":"handle","record_source":"dc:identifier.uri","access_status":null,"embargo_until":null,"access_note":null},"oai_pmh_record":{"url":"https://union.ndltd.org/oai-pmh/?verb=GetRecord&metadataPrefix=oai_dc&identifier=oai%3Aunion.ndltd.org%3Arepo%3Ayork%3Aoai%3Ayorkspace.library.yorku.ca%3A10315%2F43835","prefix":"oai_dc"},"source_record":{"url":"https://yorkspace.library.yorku.ca/oai/request?verb=GetRecord&metadataPrefix=dim&identifier=oai%3Ayorkspace.library.yorku.ca%3A10315%2F43835","prefix":"dim"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.advisor","label":"Advisor","values":["Rezai, Pouya"]},{"key":"dc:creator","label":"Author","values":["Mahmoud, Islam"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2026-07-24T15:31:34Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2026-07-24T15:31:34Z"]},{"key":"dc:date.copyright","label":"Dc Date Copyright","values":["2025-06-06"]},{"key":"dc:date.issued","label":"Date","values":["2026-07-24"]},{"key":"dc:date.updated","label":"Dc Date Updated","values":["2026-07-24T15:31:33Z"]},{"key":"dc:type","label":"Dc Type","values":["Electronic Thesis or Dissertation"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["Master's"]},{"key":"thesis:degree_name","label":"Degree Name","values":["MASc - Master of Applied Science"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Biomedical engineering","Environmental engineering","Mechanical engineering"]},{"key":"dc:subject.keyword","label":"Dc Subject Keyword","values":["Imprinted polymers","Microfluidic sensors","Fluorescence biosensors","Whole-cell imprinting","Duplex detection","Waterborne pathogens","Thin-film fabrication","Environmental monitoring"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language","label":"Dc Language","values":["en"]},{"key":"dc:rights","label":"Dc Rights","values":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.uri","label":"Identifier URI","values":["https://hdl.handle.net/10315/43835"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["Waterborne pathogens threaten public health, but standard detection methods—culture plating and molecular assays—are slow, laborious, and confined to centralized labs. Biosensors promise rapid, on-site monitoring, yet antibody-based designs demand cold-chain handling and are fragile. This thesis introduces a fluorescence microfluidic sensor built on whole-cell imprinted polymers (CIPs), offering a robust, reagent-free alternative for duplex detection in water. CIP thin films were formed in situ within microchannels by polymerizing around target bacterial cells, creating selective cavities. Multiple CIP regions on a single chip enable parallel capture of different species. After trapping cells, optimized FITC injection generates a fluorescence signal proportional to bacterial concentration. In singleplex tests with Salmonella, the sensor achieved a limit of detection (LOD) of 1.47 × 10³ CFU/mL, a limit of quantification (LOQ) of 5.28 × 10³ CFU/mL, and a linear response from 10³ to 10⁷ CFU/mL. Selectivity assays showed preferential Salmonella binding over non-targets. Duplex mode captured both Salmonella and E. coli concurrently at concentrations above 10⁵ CFU/mL. Although multiplexing reduced sensitivity, the CIP-based sensor requires minimal sample volume, no complex prep, and avoids cold storage, underscoring its field-ready potential. Future work will focus on polymer optimization, signal amplification, and validation with real environmental samples."]},{"key":"dc:title","label":"Title","values":["Fluorometric Detection of Multiple Bacteria in Water Using Cell Imprinted Polymer Thin Films Integrated into a Microfluidic Channel"]},{"key":"others:access_status","label":"Others Access Status","values":["open.access"]}]}],"canonical_facts":{"dc:contributor.advisor":["Rezai, Pouya"],"dc:creator":["Mahmoud, Islam"],"dc:date.accessioned":["2026-07-24T15:31:34Z"],"dc:date.available":["2026-07-24T15:31:34Z"],"dc:date.copyright":["2025-06-06"],"dc:date.issued":["2026-07-24"],"dc:date.updated":["2026-07-24T15:31:33Z"],"dc:description.abstract":["Waterborne pathogens threaten public health, but standard detection methods—culture plating and molecular assays—are slow, laborious, and confined to centralized labs. Biosensors promise rapid, on-site monitoring, yet antibody-based designs demand cold-chain handling and are fragile. This thesis introduces a fluorescence microfluidic sensor built on whole-cell imprinted polymers (CIPs), offering a robust, reagent-free alternative for duplex detection in water. CIP thin films were formed in situ within microchannels by polymerizing around target bacterial cells, creating selective cavities. Multiple CIP regions on a single chip enable parallel capture of different species. After trapping cells, optimized FITC injection generates a fluorescence signal proportional to bacterial concentration. In singleplex tests with Salmonella, the sensor achieved a limit of detection (LOD) of 1.47 × 10³ CFU/mL, a limit of quantification (LOQ) of 5.28 × 10³ CFU/mL, and a linear response from 10³ to 10⁷ CFU/mL. Selectivity assays showed preferential Salmonella binding over non-targets. Duplex mode captured both Salmonella and E. coli concurrently at concentrations above 10⁵ CFU/mL. Although multiplexing reduced sensitivity, the CIP-based sensor requires minimal sample volume, no complex prep, and avoids cold storage, underscoring its field-ready potential. Future work will focus on polymer optimization, signal amplification, and validation with real environmental samples."],"dc:identifier.uri":["https://hdl.handle.net/10315/43835"],"dc:language":["en"],"dc:rights":["Author owns copyright, except where explicitly noted. Please contact the author directly with licensing requests."],"dc:subject":["Biomedical engineering","Environmental engineering","Mechanical engineering"],"dc:subject.keyword":["Imprinted polymers","Microfluidic sensors","Fluorescence biosensors","Whole-cell imprinting","Duplex detection","Waterborne pathogens","Thin-film fabrication","Environmental monitoring"],"dc:title":["Fluorometric Detection of Multiple Bacteria in Water Using Cell Imprinted Polymer Thin Films Integrated into a Microfluidic Channel"],"dc:type":["Electronic Thesis or Dissertation"],"others:access_status":["open.access"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["Master's"],"thesis:degree_name":["MASc - Master of Applied Science"]},"updated_at":"2026-11-19T09:47:00Z"}