Estudo da tratabilidade do lixiviado de aterro sanitário pelos processos oxidativos avançados foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio / Study of treatability of landfill leachate by advanced oxidation processes photo-Fenton, ozone and ozone combined with hydrogen peroxide

Monteiro, Luciano do Valle 05 June 2012 (has links)
O lixiviado de aterro sanitário possui constituição complexa e é altamente poluente. Neste contexto, os processos oxidativos avançados se destacam como pré-tratamento, objetivando a remoção ou diminuição da recalcitrância do lixiviado. Neste trabalho foram utilizados os Processos Oxidativos Avançados (POAs) foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio. Avaliou-se a influência do pré-tratamento por air-stripping, a variação na produção de ozônio em 80 e 100%, a melhor dose de peróxido de hidrogênio correspondente a 20, 40 e 80% da dose de 6g O3/L empregada nos tratamentos com ozônio, a remoção de matéria orgânica, nitrogênio amoniacal total (NAT), alcalinidade, sólidos dissolvidos totais (SDT) (cloretos), produção de nitrito e nitrato, melhor razão molar [H2O2]/[Fe2+] para o tempo de contato de 80 min no foto-Fenton, uso do número médio de oxidação do carbono (NMOC) e a quantificação do ácido oxálico formado após a aplicação dos POAs. O tratamento por O3/H2O2 (1,2 g H2O2/L e produção de O3 em 80%) obteve a maior remoção de matéria orgânica, 0,14 g massa removida de Carbono Orgânico Total (COT) / massa consumida de O3 e 0,43 g/g para a Demanda Química de Oxigênio (DQO). Quanto ao foto-Fenton, averiguou-se o máximo de 74% remoção de COT e 65% remoção DQO para a razão molar [H2O2]/[Fe2+] igual a 2. Também se notou formação de sólidos sedimentáveis neste processo aplicado ao lixiviado bruto. O pré-tratamento por air-stripping não promoveu incremento na remoção de matéria orgânica. As concentrações de NAT, alcalinidade, SDT (cloretos) se mantiveram elevadas após a aplicação dos POA. Ocorreu formação de nitrato em todos os tratamentos. O uso do NMOC foi adequado e demonstrou ocorrência de oxidação nos processos. A quantificação do ácido oxálico formado após a aplicação dos POAs não foi apropriada nesta pesquisa. / The landfill leachate is a major waste produced by the landfill and its constitution complex and highly polluting motivate research in order to adapt their disposal on the environment. In this context, the advanced oxidation processes stand out as a pretreatment, in order to remove or decrease the recalcitrance of the leachate. In this work we used the photo-Fenton AOPs, ozone and ozone combined with hydrogen peroxide. We evaluated the effect of pretreatment for air-stripping, the variation in the production of ozone 80 and 100%, the best dose of hydrogen peroxide equal to 20, 40 and 80% of the dose of 6g O3/ L used in the treatments with ozone, the removal of organic matter, total ammonia nitrogen, alkalinity, dissolved solids (chlorides), production of nitrite and nitrate, best molar ratio [H2O2]/[Fe2+] to the contact time of 80 min in the photo-Fenton, average number of carbon oxidation use and the measurement of oxalic acid formed after application of the AOPs. The AOP O3/H2O2 (1.2g H2O2/L and O3 production by 80%) had the highest removal of organic matter, 0.14 g of TOC removed mass/ mass consumed O3 and 0.43 g/g for COD. As for the photo-Fenton, it was found a maximum of 74% removal of TOC and 65% for COD removal molar ratio [H2O2]/[Fe2+] equal to 2. It was also noted the formation of settle able solids in the process applied to the raw leachate. Pretreatment by air-stripping did not promote an increase in organic matter removal. Total ammonia nitrogen concentrations, alkalinity, dissolved solids (chlorides) remained high after application of the AOP, indicating possible oxidant demand. For nitrate formation occurred in all treatments, while only the photo-Fenton was no formation of nitrite. The use of average number of carbon oxidation was adequate and showed occurrence of oxidation processes. The quantification of oxalic acid formed after the application of AOPs was not appropriate in this research.
2

Estudo da tratabilidade do lixiviado de aterro sanitário pelos processos oxidativos avançados foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio / Study of treatability of landfill leachate by advanced oxidation processes photo-Fenton, ozone and ozone combined with hydrogen peroxide

Luciano do Valle Monteiro 05 June 2012 (has links)
O lixiviado de aterro sanitário possui constituição complexa e é altamente poluente. Neste contexto, os processos oxidativos avançados se destacam como pré-tratamento, objetivando a remoção ou diminuição da recalcitrância do lixiviado. Neste trabalho foram utilizados os Processos Oxidativos Avançados (POAs) foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio. Avaliou-se a influência do pré-tratamento por air-stripping, a variação na produção de ozônio em 80 e 100%, a melhor dose de peróxido de hidrogênio correspondente a 20, 40 e 80% da dose de 6g O3/L empregada nos tratamentos com ozônio, a remoção de matéria orgânica, nitrogênio amoniacal total (NAT), alcalinidade, sólidos dissolvidos totais (SDT) (cloretos), produção de nitrito e nitrato, melhor razão molar [H2O2]/[Fe2+] para o tempo de contato de 80 min no foto-Fenton, uso do número médio de oxidação do carbono (NMOC) e a quantificação do ácido oxálico formado após a aplicação dos POAs. O tratamento por O3/H2O2 (1,2 g H2O2/L e produção de O3 em 80%) obteve a maior remoção de matéria orgânica, 0,14 g massa removida de Carbono Orgânico Total (COT) / massa consumida de O3 e 0,43 g/g para a Demanda Química de Oxigênio (DQO). Quanto ao foto-Fenton, averiguou-se o máximo de 74% remoção de COT e 65% remoção DQO para a razão molar [H2O2]/[Fe2+] igual a 2. Também se notou formação de sólidos sedimentáveis neste processo aplicado ao lixiviado bruto. O pré-tratamento por air-stripping não promoveu incremento na remoção de matéria orgânica. As concentrações de NAT, alcalinidade, SDT (cloretos) se mantiveram elevadas após a aplicação dos POA. Ocorreu formação de nitrato em todos os tratamentos. O uso do NMOC foi adequado e demonstrou ocorrência de oxidação nos processos. A quantificação do ácido oxálico formado após a aplicação dos POAs não foi apropriada nesta pesquisa. / The landfill leachate is a major waste produced by the landfill and its constitution complex and highly polluting motivate research in order to adapt their disposal on the environment. In this context, the advanced oxidation processes stand out as a pretreatment, in order to remove or decrease the recalcitrance of the leachate. In this work we used the photo-Fenton AOPs, ozone and ozone combined with hydrogen peroxide. We evaluated the effect of pretreatment for air-stripping, the variation in the production of ozone 80 and 100%, the best dose of hydrogen peroxide equal to 20, 40 and 80% of the dose of 6g O3/ L used in the treatments with ozone, the removal of organic matter, total ammonia nitrogen, alkalinity, dissolved solids (chlorides), production of nitrite and nitrate, best molar ratio [H2O2]/[Fe2+] to the contact time of 80 min in the photo-Fenton, average number of carbon oxidation use and the measurement of oxalic acid formed after application of the AOPs. The AOP O3/H2O2 (1.2g H2O2/L and O3 production by 80%) had the highest removal of organic matter, 0.14 g of TOC removed mass/ mass consumed O3 and 0.43 g/g for COD. As for the photo-Fenton, it was found a maximum of 74% removal of TOC and 65% for COD removal molar ratio [H2O2]/[Fe2+] equal to 2. It was also noted the formation of settle able solids in the process applied to the raw leachate. Pretreatment by air-stripping did not promote an increase in organic matter removal. Total ammonia nitrogen concentrations, alkalinity, dissolved solids (chlorides) remained high after application of the AOP, indicating possible oxidant demand. For nitrate formation occurred in all treatments, while only the photo-Fenton was no formation of nitrite. The use of average number of carbon oxidation was adequate and showed occurrence of oxidation processes. The quantification of oxalic acid formed after the application of AOPs was not appropriate in this research.
3

Recuperação da amônia liberada no processo de \"air stripping\" aplicado ao tratamento do lixiviado de aterros sanitários / Recovery of ammonia released from air stripping process applied to sanitary landfill leachate treatment

Ferraz, Fernanda de Matos 26 March 2010 (has links)
O lixiviado de aterros sanitários é um efluente líquido poluente devido, principalmente, à sua elevada concentração de amônia. Seu tratamento faz-se necessário para que sejam atendidas as exigências das legislações ambiental e trabalhista, além de minimizados os impactos ambientais de seu lançamento nos corpos d\'água. Esta pesquisa propõe a remoção da amônia presente no lixiviado por meio do processo físico-químico \"air stripping\", que promove a transferência da amônia da fase líquida para gasosa. Para que não se contribua com a poluição atmosférica, o efluente gasoso do \"air stripping\" deve ser tratado em solução de ácido sulfúrico ou água. A neutralização da amônia com solução de ácido sulfúrico gera o sulfato de amônio, e com água, a aquamônia. Tais subprodutos podem ser usados como fertilizantes. Nesta pesquisa, para remoção da amônia do lixiviado foi utilizada uma torre de PVC, com 2,24 m de altura e 15 cm de diâmetro, recheada com anéis do tipo Rashing de polietileno corrugados, com diâmetro de 1,5 cm e 5 cm de comprimento. As vazões de ar utilizadas foram 1200, 1600 e 3600 L/h e as vazões de lixiviado foram 18 e 30 L/h. Para ajuste no pH do lixiviado, utilizou-se hidróxido de cálcio (padrão analítico) e cal comercial. Os fluxos de líquido e ar eram em contracorrente. Para o recolhimento da amônia foram usados dois frascos de 6 L, preenchidos com 4 L de solução de ácido sulfúrico 0,4 mol/L ou água. Os resultados obtidos indicaram remoção praticamente completa de toda a amônia contida no lixiviado. Nas diferentes condições operacionais avaliadas, a concentração de amônia remanescente no lixiviado foi igual ou inferior aos 20 mg/L determinados pela Resolução 397/08 do CONAMA. Quanto ao recolhimento da amônia, a eficiência média obtida nos frascos lavadores próxima a 80%, tanto ) quando utilizada a solução de ácido sulfúrico 0,4 mol/L quanto quando utilizada água. / Sanitary landfill leachate is a pollutant liquid effluent mainly due to its high ammonia concentration. Its treatment is necessary due to environmental and labour legislation requirements, besides prevention of environmental impacts of leachate release in water bodies. This research proposes ammonia removal from leachate by air stripping process, which transfers ammonia from liquid to gaseous phase. In order to prevent atmospheric pollution, air stripping gaseous effluent must be treated with sulphuric acid solution or water. Ammonia neutralization by sulfuric generates ammonium sulfate and by water, aquammonia is generated. Such by-products may be used as fertilizer. In this research, in order to remove leachate ammonia it was used a PVC tower of 2.24 m high and 15 cm diameter, packed with Rashing rings of corrugated polyethylene of 1.5 cm diameter and 5 cm length. Air flows were 1200, 1600 and 3600 L/h and leachete flows were 18 e 30 L/h. Calcium carbonate (standard grade) and commercial hydrated lime were used for pH adjustments. Air and liquid flows were countercurrent. In order to recover ammonia, two flasks of 6 L were used and filled with 4 L of 0.4 mol/L sulfuric acid solution or water. Results showed that ammonia was almost completely removed from leachate. In all operational conditions evaluated, remaining ammonia concentration in leachate was equal or less than 20 mg/L, value established by Resolution 397/08 of Brazilian Council of the Environment. Ammonia recovery with water or a 0.4 mol/L sulfuric acid solution was about 80%.
4

Recuperação da amônia liberada no processo de \"air stripping\" aplicado ao tratamento do lixiviado de aterros sanitários / Recovery of ammonia released from air stripping process applied to sanitary landfill leachate treatment

Fernanda de Matos Ferraz 26 March 2010 (has links)
O lixiviado de aterros sanitários é um efluente líquido poluente devido, principalmente, à sua elevada concentração de amônia. Seu tratamento faz-se necessário para que sejam atendidas as exigências das legislações ambiental e trabalhista, além de minimizados os impactos ambientais de seu lançamento nos corpos d\'água. Esta pesquisa propõe a remoção da amônia presente no lixiviado por meio do processo físico-químico \"air stripping\", que promove a transferência da amônia da fase líquida para gasosa. Para que não se contribua com a poluição atmosférica, o efluente gasoso do \"air stripping\" deve ser tratado em solução de ácido sulfúrico ou água. A neutralização da amônia com solução de ácido sulfúrico gera o sulfato de amônio, e com água, a aquamônia. Tais subprodutos podem ser usados como fertilizantes. Nesta pesquisa, para remoção da amônia do lixiviado foi utilizada uma torre de PVC, com 2,24 m de altura e 15 cm de diâmetro, recheada com anéis do tipo Rashing de polietileno corrugados, com diâmetro de 1,5 cm e 5 cm de comprimento. As vazões de ar utilizadas foram 1200, 1600 e 3600 L/h e as vazões de lixiviado foram 18 e 30 L/h. Para ajuste no pH do lixiviado, utilizou-se hidróxido de cálcio (padrão analítico) e cal comercial. Os fluxos de líquido e ar eram em contracorrente. Para o recolhimento da amônia foram usados dois frascos de 6 L, preenchidos com 4 L de solução de ácido sulfúrico 0,4 mol/L ou água. Os resultados obtidos indicaram remoção praticamente completa de toda a amônia contida no lixiviado. Nas diferentes condições operacionais avaliadas, a concentração de amônia remanescente no lixiviado foi igual ou inferior aos 20 mg/L determinados pela Resolução 397/08 do CONAMA. Quanto ao recolhimento da amônia, a eficiência média obtida nos frascos lavadores próxima a 80%, tanto ) quando utilizada a solução de ácido sulfúrico 0,4 mol/L quanto quando utilizada água. / Sanitary landfill leachate is a pollutant liquid effluent mainly due to its high ammonia concentration. Its treatment is necessary due to environmental and labour legislation requirements, besides prevention of environmental impacts of leachate release in water bodies. This research proposes ammonia removal from leachate by air stripping process, which transfers ammonia from liquid to gaseous phase. In order to prevent atmospheric pollution, air stripping gaseous effluent must be treated with sulphuric acid solution or water. Ammonia neutralization by sulfuric generates ammonium sulfate and by water, aquammonia is generated. Such by-products may be used as fertilizer. In this research, in order to remove leachate ammonia it was used a PVC tower of 2.24 m high and 15 cm diameter, packed with Rashing rings of corrugated polyethylene of 1.5 cm diameter and 5 cm length. Air flows were 1200, 1600 and 3600 L/h and leachete flows were 18 e 30 L/h. Calcium carbonate (standard grade) and commercial hydrated lime were used for pH adjustments. Air and liquid flows were countercurrent. In order to recover ammonia, two flasks of 6 L were used and filled with 4 L of 0.4 mol/L sulfuric acid solution or water. Results showed that ammonia was almost completely removed from leachate. In all operational conditions evaluated, remaining ammonia concentration in leachate was equal or less than 20 mg/L, value established by Resolution 397/08 of Brazilian Council of the Environment. Ammonia recovery with water or a 0.4 mol/L sulfuric acid solution was about 80%.