• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception et conduite de systèmes d'électrolyse à haute température alimentés par des énergies renouvelables

Petipas, Floriane 17 May 2013 (has links) (PDF)
Le " Power-to-Gas " pourrait devenir une solution attractive pour le stockage des énergies renouvelables, pourvu que des électrolyseurs soient capables de fonctionner efficacement dans des conditions intermittentes à un coût abordable. Ce travail a pour objectif d'évaluer la faisabilité technique du fonctionnement intermittent de systèmes d'électrolyse à oxyde solide (SOEC) autour de 1073 K. Des conditions réalistes défavorables sont considérées, consistant en un système autonome sans source externe de chaleur et intégrant une compression d'hydrogène à 3 MPa. La problématique se compose de deux aspects : i) la gamme de fonctionnement du système, limitée à 60-100% en raison de gradients thermiques, est étendue via des stratégies de contrôle efficaces, ii) des procédures sont définies pour minimiser l'impact de l'intermittence sur la durée de vie. Premièrement, une stratégie de contrôle modulaire est proposée, consistant en l'utilisation de plusieurs unités indépendantes qui fonctionnent dans une gamme de puissance tolérable, ou sont arrêtées. La gamme de fonctionnement du système est ainsi étendue à 15-100% dans le cas de quatre unités. Une stratégie de contrôle complémentaire, consistant en un chauffage électrique interne, permet d'étendre la gamme de fonctionnement en réduisant les gradients thermiques, mais elle est susceptible de diminuer la durée de vie. Elle n'est donc appliquée qu'à une unité afin de suivre la courbe de charge et d'étendre la gamme de fonctionnement du système à 3-100%. Deuxièmement, 1800 cycles électriques on-off sont appliqués à une SOEC sans impact sur la dégradation, ce qui montre que des arrêts/démarrages répétés ne diminuent pas la durée de vie. De plus, des procédures de démarrage, standby et arrêt sont définies. Enfin, deux études de systèmes Eolien-SOEC et Solaire-SOEC fonctionnant pendant un an montrent que, avec les stratégies de contrôle implémentées, le système SOEC stocke la puissance appliquée avec un rendement de 92% sur PCS en moyenne, alors que les unités fonctionnent dans des conditions tolérables mis à part une unité qui suit la courbe de charge et est susceptible d'avoir une durée de vie diminuée.
2

Power-to-gas : développement d’un réacteur catalytique pour la production de méthane de synthèse / Power-to-gas : development of a catalytic methanation reactor

Fache, Axel 12 February 2019 (has links)
Un frein majeur au développement des énergies renouvelables à finalité électrogène réside dans l’inadéquation entre les moments de forte disponibilité des ressources, et les moments de forte demande de la part des consommateurs. Un élément de solution éventuel consisterait à utiliser l’énergie électrique excédentaire, en périodes de surproduction, pour produire du méthane de synthèse (power-to-gas). Cette approche présente l’avantage d’autoriser un lissage à l’échelle des saisons, car le méthane peut être stocké, transporté et utilisé facilement avec les systèmes existants. La réaction de méthanation CO_2+4.H_2⇄CH_4+2.H_2 O, étape clé de la chaine de power-to-gas, peut être réalisée dans un réacteur catalytique à lit fixe refroidi par la paroi. La conception d’un tel réacteur présente des difficultés d’ordre théorique et technologique. Du fait de la forte exothermicité de la réaction, cette dernière tend à être instable (emballement vs. extinction). De plus, la puissance électrique excédentaire varie au cours du temps : le régime de fonctionnement du réacteur (débit de mélange réactif à convertir) doit pouvoir varier en conséquence. L’exigence de fonctionnement dynamique, pour une réaction instable, fait apparaitre des difficultés spécifiques auxquelles ne sont pas confrontés les réacteurs fonctionnant en régime permanent (risque d’emballement transitoire). Dans ce contexte, un projet impliquant le Laboratorie de Thermique, Energétique et Procédés et la start-up industrielle ENOSIS a été mis en place pour contribuer au développement d’un réacteur performant et sûr. Ce projet bénéficie du financement de la région Nouvelle-Aquitaine.Dans la présente thèse, un critère théorique est introduit pour quantifier la marge de sécurité dont bénéficie un réacteur vis-à-vis des instabilités transitoires. Un logiciel est développé pour simuler, au premier ordre, le fonctionnement dynamique d’un réacteur. Cela permet d’illustrer l’optimisation d’un réacteur, en prenant en compte la contrainte de stabilité transitoire. Il est montré que l’utilisation d’un catalyseur dont la dilution est étagée, stratégie connue pour améliorer la sécurité et la performance des réacteurs en fonctionnement permanent, peut se réveler contre-productive en regard de critères transitoires de performance et/ou de sécurité. Une caractéristique clé du fonctionnement intermittent réside dans le temps de démarrage (ou de redémarrage à chaud) de la réaction, lors de l’injection soudaine de réactifs. Aussi, un examen de la durée de (re)démarrage d’un réacteur en fonction de sa température juste avant injection est mené. La relation entre température et vitesse de (re)démarrage se révèle approximativement affine. Dans un second temps, un modèle plus précis est développé et le logiciel correspondant est écrit, afin de distinguer le comportement thermique des grains catalytiques proprement-dits du comportement de grains inertes. Ces derniers, outre leur rôle de diluant, peuvent également présenter des propriétés thermiques dont l’exploitation autoriserait possiblement une stabilisation des transitoires critiques. Aussi, quelques simulations sont lancées sur des configurations de réacteur non-conventionnelles (grains inertes pouvant être chauffés par induction, grains à changement de phase). Les résultats obtenus permettent de mieux appréhender certaines difficultés qui seront à résoudre pour permettre l’utilisation éventuelle de ces technologies disruptives. En complément du travail théorique et numérique, une micro-campagne expérimentale a été menée au sein du Combustion and Catalysis Laboratory de New-York (mise en place d’un dispositif, collecte de premières données en vue d’une validation).En parallèle de ces différents axes de recherche, une solution technologique brevetable (non détaillée dans le présent manuscrit) a également été trouvée. / The development of renewable energy for electricity generation is significantly hindered by the discrepancy between the moments when high amounts of energy are available and the moments when consumers demand most power supply. A prospective solution consists in using electric power surplus to produce synthetic methane, during extra production periods (power-to-gas). This solution would enable to smoothen the electric balance from a season to another, since methane can be easily stored, transported and used in existing devices. The methanation reaction CO_2+4.H_2⇄CH_4+2.H_2 O is a key step in power-to-gas. It can be completed in a fixed-bed wall-cooled reactor. Designing such a reactor leads to theoretical and technological difficulties. Because the reaction is highly exothermic, it tends to be unstable (runaway vs. blow-out). Moreover, power surplus varies over time: the reactor must therefore enable dynamic operation (reactants flow rate variations). Dynamic completion of an unstable reaction leads to specific issues which do not exist for steady-state operating reactors (risk of a transient runaway). In this context, a project involving the Laboratoire de Thermique, Energétique et Procédés and the start-up company ENOSIS has been set up (with the financial support of French region Nouvelle-Aquitaine), to obtain a contribution to the development of a safe and efficient reactor. In the present work, a theoretical criterion is introduced to quantify the safety margin of a reactor towards transient instabilities. A software is developed to perform a simplified simulation of a reactor’s dynamic operation. This simulation tool is used to illustrate the process of optimizing a reactor, taking into account the transient stability constraint. It is shown that using a staggered catalyst dilution – a well known strategy to improve safety and efficiency for steady state operating reactors – can be counter-productive when it comes to transient safety/efficiency criteria. A key characteristic of intermittent operation lies in the start-up time (or warm restart-up time) of the reaction, when reactants are injected sharply. Therefore, we examined the (re)start-up time of a reactor as a function of its temperature just before injection begins. The temperature-(re)start time relation turns out to be nearly linear.Secondly, a more accurate model is developed and the corresponding software is encoded, with the aim of distinguishing the catalytic pellets from the inert pellets, in terms of thermal behavior. Not only do inert pellets play a diluting role, but they can also have specific thermal properties to stabilize critical transient sequences. A few simulations are thus performed on non-conventional reactor configurations (inert grains can be heated by induction, or undergo a phase change). The results provide a better understanding of some difficulties that should be solved before such disruptive technologies could eventually be operational.As a complement to the theoretical and numerical work, a micro experimental campaign is performed in the Combustion and Catalysis Laboratory of New-York (setting-up an experimental device, collecting data for future validation of the simulator).Alongside these lines of research, a patentable technological solution has also been found (not detailed in this manuscript).
3

Conception et conduite de systèmes d’électrolyse à haute température alimentés par des énergies renouvelables / Design and control of high temperature electrolyser systems fed with renewable energies

Petipas, Floriane 17 May 2013 (has links)
Le « Power-to-Gas » pourrait devenir une solution attractive pour le stockage des énergies renouvelables, pourvu que des électrolyseurs soient capables de fonctionner efficacement dans des conditions intermittentes à un coût abordable. Ce travail a pour objectif d'évaluer la faisabilité technique du fonctionnement intermittent de systèmes d'électrolyse à oxyde solide (SOEC) autour de 1073 K. Des conditions réalistes défavorables sont considérées, consistant en un système autonome sans source externe de chaleur et intégrant une compression d'hydrogène à 3 MPa. La problématique se compose de deux aspects : i) la gamme de fonctionnement du système, limitée à 60-100% en raison de gradients thermiques, est étendue via des stratégies de contrôle efficaces, ii) des procédures sont définies pour minimiser l'impact de l'intermittence sur la durée de vie. Premièrement, une stratégie de contrôle modulaire est proposée, consistant en l'utilisation de plusieurs unités indépendantes qui fonctionnent dans une gamme de puissance tolérable, ou sont arrêtées. La gamme de fonctionnement du système est ainsi étendue à 15-100% dans le cas de quatre unités. Une stratégie de contrôle complémentaire, consistant en un chauffage électrique interne, permet d'étendre la gamme de fonctionnement en réduisant les gradients thermiques, mais elle est susceptible de diminuer la durée de vie. Elle n'est donc appliquée qu'à une unité afin de suivre la courbe de charge et d'étendre la gamme de fonctionnement du système à 3-100%. Deuxièmement, 1800 cycles électriques on-off sont appliqués à une SOEC sans impact sur la dégradation, ce qui montre que des arrêts/démarrages répétés ne diminuent pas la durée de vie. De plus, des procédures de démarrage, standby et arrêt sont définies. Enfin, deux études de systèmes Eolien-SOEC et Solaire-SOEC fonctionnant pendant un an montrent que, avec les stratégies de contrôle implémentées, le système SOEC stocke la puissance appliquée avec un rendement de 91% sur PCS en moyenne, alors que les unités fonctionnent dans des conditions tolérables mis à part une unité qui suit la courbe de charge et est susceptible d'avoir une durée de vie diminuée. / Power-to-Gas could become an attractive solution for renewable electricity storage, provided that affordable electrolysers are able to operate efficiently under intermittent conditions. This work aims to assess the technical feasibility of operating intermittently a Solid Oxide Electrolysis Cell (SOEC) system around 1073 K. Realistic unfavourable conditions are considered, consisting in a standalone system operated with no external heat source and integrating hydrogen compression to 3 MPa. Two challenges are tackled in this work: i) the system power load range, limited to 60-100% due to thermal gradients, is extended via efficient control strategies, ii) procedures are defined to minimise the impact of the intermittency on the lifetime. First, a modular control strategy is proposed, consisting in the use of several SOEC units which are either operated in a tolerable power load range, or switched off. The system power load range is hence extended to 15-100% in the case of four units. A complementary control strategy, consisting in internal electrical heating, enables to extend the load range by reducing thermal gradients, but it may decrease the lifetime. Thus, it is applied to only one unit for it to follow the load curve and extend the system power load range to 3-100%. Secondly, 1800 on-off electric cycles are applied to an SOEC with no degradation increase, which shows that repeated start/stops do not decrease the lifetime. Start-up, standby and shut-down procedures are also defined. Finally, two case studies of Wind-SOEC and Solar-SOEC systems operated over one year show that, with the implemented control strategies, the SOEC system stores the applied power with an average efficiency of 91% vs. HHV, while units operate under tolerable conditions apart from one unit which follows the load curve and may have a decreased lifetime.

Page generated in 0.1662 seconds