• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 6
  • 6
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

STUDY ON STRATEGIES TO REDUCE MEMBRANE SCALING AND FOULING IN DRINKING WATER AND WATER REUSE MEMBRANE SYSTEMS

Yan, Dongxu January 2011 (has links)
Central Arizona Project (CAP) water was treated using the process of slowsand filtration, chemical pretreatment and RO membrane. Both bench scale plate and frame reactor and pilot scale tests suggested RO membrane fouling by clay and organic matter with minor scaling by CaCO3 and BaSO4. Several strategies were studied to reduce RO membrane fouling and scaling. The first is choosing optimized operation conditions through bench scale tests. The second is to modify the traditional concentration polarization model for a better fouling/scaling prediction. This modified model was also used to optimize concentrate spacer design, which leads to reduced concentration polarization index. The third is to develop a method for anti-scalant test and comparison, which can be used for anti-scalant selection and dose optimization.Additional to these strategies, pre-oxidation pretreatment for RO membrane in water reuse application was investigated at bench and pilot scale. In the MBR-Ozone-RO train study, ozone showed certain impact on RO membrane fouling, but no significant difference was made on membrane cleaning frequency. UV and UV/AOP impacts on RO membrane fouling tests were done on plate and frame reactor. UV did not show any competency to reduce membrane fouling, while UV/AOP tests showed promising results by reducing RO membrane fouling rate by 50%.
2

The separation of hydrogen and carbon monoxide using polymer membranes

Hinchliffe, Anthony Bernard January 1991 (has links)
This work studies the development of polymer membranes for the separation of hydrogen and carbon monoxide from a syngas produced by the partial oxidation of natural gas. The CO product is then used for the large scale manufacture of acetic acid by reaction with methanol. A method of economic evaluation has been developed for the process as a whole and a comparison is made between separation of the H2/CO mixture by a membrane system and the conventional method of cryogenic distillation. Costs are based on bids obtained from suppliers for several different specifications for the purity of the CO fed to the acetic acid reactor. When the purity of the CO is set at that obtained by cryogenic distillation it is shown that the membrane separator offers only a marginal cost advantage. Cost parameters for the membrane separation systems have been defined in terms of effective selectivity and cost permeability. These new parameters, obtained from an analysis of the bids, are then used in a procedure which defines the optimum degree of separation and recovery of carbon monoxide for a minimum cost of manufacture of acetic acid. It is shown that a significant cost reduction is achieved with a membrane separator at the optimum process conditions. A method of "targeting" the properties of new membranes has been developed. This involves defining the properties for new (hypothetical -yet to be developed) membranes such that their use for the hydrogen/carbon monoxide separation will produce a reduced cost of acetic acid manufacture. The use of the targeting method is illustrated in the development of new membranes for the separation of hydrogen and carbon monoxide. The selection of polymeric materials for new membranes is based on molecular design methods which predict the polymer properties from the molecular groups making up the polymer molecule. Two approaches have been used. One method develops the analogy between gas solubility in liquids and that in polymers. The UNIFAC group contribution method is then used to predict gas solubility in liquids. In the second method the polymer Permachor number, developed by Salame, has been correlated with hydrogen and carbon monoxide permeabilities. These correlations are used to predict the permeabilities of gases through polymers. Materials have been tested for hydrogen and carbon monoxide permeabilities and improvements in expected economic performance have been achieved.
3

In-line coagulation to reduce high-pressure membrane fouling in an integrated membrane system

Zevenhuizen, Emily Lauren 31 July 2013 (has links)
Membrane fouling is a chronic problem for many nanofiltration (NF) membrane plants. Foulant material can range from colloidal, particulate, inorganic minerals and natural organic matter (NOM) (Schäfer et al., 2006). This research project worked with a small community integrated membrane facility (low-pressure membrane followed by high-pressure) in Nova Scotia with membrane fouling concerns associated with dissolved NOM as the primary foulant. Membrane autopsies conducted in our laboratory have demonstrated that NOM deposits on the NF membrane decreased pore space on the membrane (Lamsal et al., 2012). The membrane fouling resulted in a requirement for increased pressure to produce a constant permeate flow. By adding in-line coagulation prior to low-pressure filtration in an integrated membrane system, the goal was to remove more organic material by MF thereby improving the quality of the feed-water entering the NF membranes. Previous work has shown that for some IMS installations there is a need to reduce the amount of dissolved organic matter prior to NF (Cho et al., 2000; Lamsal et al., 2012; Nilson and DiGiano, 1996; Schäfer et al., 2001). An improved membrane feed-water quality reduces fouling on the membrane and membrane operating cost, and increases productivity and lifespan of the membrane (Choi, 2008). A negative aspect to adding in-line coagulation is it adds another step to the treatment process and sludge removal is required. This study examined the use of in-line coagulation using coagulants aluminum sulphate, ferric chloride and polyaluminum chloride to improve membrane feed-water quality. The addition of in-line coagulation prior to microfiltration will remove NOM with the MF producing improved feed water quality for NF. After determining the optimal dose of each coagulant, 20 L of post-coagulation MF permeate was batched and run through the bench-scale NF membrane for 200 hours. The water quality of the feed tank, concentrate and permeate were monitored constantly as well as the operational properties of pressure and flow. To simulate a full-scale plant the operating conditions of Collins Park water treatment plant on Fletchers Lake were used in the bench-scale set-up. After the 200h NF run time the membranes were analyzed to assess the fouling on the membrane and the performance of each coagulant. Coagulation was found to reduce NF pressure fouling by reduction of NOM in the NF feed-water. Ferric chloride was found to perform best of the three coagulants at a low dose of 0.5mg/L of Fe at a pH of 5.0. / n/a
4

Optimisation of membrane technology for water reuse

Raffin, Marie January 2011 (has links)
Increasing freshwater scarcity is making reclamation of wastewater effluent more economically attractive as a means of preserving freshwater resources. The use of an integrated membrane system (IMS), the combination of micro/ultra-filtration (MF/UF) followed by reverse osmosis (RO) membranes, represents a key process for municipal wastewater reuse. A major drawback of such systems is the fouling of both the MF/UF and RO membranes. The water to be treated by the IMS system varies from one wastewater treatment plant (WWTP) to another, and its fouling propensity changes correspondingly. It is thus preferable to conduct pilot trials before implementing a full-scale plant. This thesis aims to look at the sustainability of IMS technology dedicated to indirect potable reuse (IPR) in terms of fouling minimisation and cost via a 600 m3 .d- 1 pilot plant. Wastewater reuse plants, using IMS, as well as statistical methods for membrane optimisation were reviewed. Box-Behnken design was used to define optimum operating envelopes of the pilot plant for both the microfiltration and the reverse osmosis in terms of fouling minimisation. Same statistical method was used to enhance the efficiency of the MF cleaning-in place through bench-scale test. Data from the pilot plant MF process allow to determine relationship between reversible and irreversible fouling, and operating parameters and feed water quality. Life cycle cost analysis (LCCA) of the both trains (MF/RO/AOP and MF/AOP) of the pilot plant was performed and compared with the LCCA of two full-scale plant.
5

Integration testing of heterotic systems

Stannett, M., Gheorghe, Marian 15 June 2015 (has links)
Yes / Computational theory and practice generally focus on single-paradigm systems, but relatively little is known about how best to combine components based on radically different approaches (e.g. silicon chips and wetware) into a single coherent system. In particular, while testing strategies for single-technology artefacts are generally well developed, it is unclear at present how to perform integration testing on heterotic systems: can we develop a test-set generation strategy for checking whether specified behaviours emerge (and unwanted behaviours do not) when components based on radically different technologies are combined within a single system? In this paper, we describe an approach to modelling multi-technology heterotic systems using a general-purpose formal specification strategy based on Eilenberg's X-machine model of computation. We show how this approach can be used to represent disparate technologies within a single framework, and propose a strategy for using these formal models for automatic heterotic test-set generation. We illustrate our approach by showing how to derive a test set for a heterotic system combining an X-machine-based device with a cell-based P system (membrane system).
6

Studies On The Application Of Liquid Membranes For The Removal Of Dissolved Metals From Effluents

Kumar, Vijaya S 06 1900 (has links)
Separation of dissolved metals from aqueous solutions using liquid membrane technology is highly advantageous owing to the degree of separation achieved, efficiency and application potential. In the present investigation four types of liquid membranes - bulk liquid membrane (BLM), emulsion liquid membrane (ELM), electrostatic pseudo liquid membrane (ESPLIM) and unified liquid membrane (ULM) have been extensively studied, for their application in extraction and concentration of dissolved metals from effluents. Experiments were conducted with various metal systems to optimize both system and process conditions and to find out the effect of various parameters on the performance of the process. Different mass transport models were proposed for each type, taking diffusional and kinetic resistances into account. Models were extended for simultaneous extraction systems and were verified by different metal-carrier experiments. Good agreement was found between the concentration profiles obtained from the models and the experimental data, thereby establishing the validity of models for all the four types of liquid membranes. The stirred cell employed in BLM process eliminates emulsification and demulsification processes. It also provides simultaneous contact of the organic liquid membrane phase with aqueous feed and strip phases. Overall rate expressions for extraction and stripping in BLM are based on an assumed kinetic mechanism to explain the process qualitatively. It was found that the magnitude^ of diffusional and kinetic resistances determines the overall mass transfer coefficient. The relative magnitude of mass transfer coefficient, reaction rate constants and equilibrium constants enables to visualize the controlling regime of the process. The problem of low flux rate due to high diffusion resistances, inefficient operation and exorbitant costs encountered in bulk and supported liquid membranes (SLM) are overcome in an ELM. In the ELM process, an emulsion of organic membrane phase and aqueous inner phase, is dispersed in the continuous aqueous feed phase. This gives a highly selective and ultra thin liquid film generating a large mass transfer area for separation. Experimental results on membrane instability and emulsion swelling indicate that volumetric leakage rate depends linearly on the stirring speed and that the nature of surfactant does not have any appreciable effect on emulsion swelling. A general permeation model was developed taking into account the external mass transfer around the emulsion drop, diffusion in the drop, reaction at the aqueous-organic interface, leakage of the internal phase to the external phase due to membrane breakup and emulsion swelling due to osmotic pressure difference. Model equations with appropriate boundary conditions were numerically solved by orthogonal collocation technique for a set of model parameters obtained either from known correlations or from independent experiments. Comparison of the model predictions with experimental data from the batch permeation of chromium and other metals using carrier Alamine 336 or LIX 64N, shows that the model predictions are in very good agreement with the experimental findings. Further this model can be used to simulate the effects of various experimental conditions such as metal and hydrogen ion concentrations, carrier concentration, drop diameters, etc., for similar systems. Studies on ESPLIM were conducted with the aim of demonstrating the effectiveness of this new separation process and to develop a simple transport model for metal permeation. In the ESPLIM process, a high electrical field (3-5 kV A.C.) is used for phase dispersion. This system consists of a rectangular reactor filled with membrane solution divided into extraction and stripping cells by a centrally placed integrated type baffle which also acts as an electrode. Two more electrodes were placed in the extraction and stripping cells, where feed and strip phases are introduced from the top of the reactor. When high electrical field is applied across the electrodes, fine droplets of feed and strip are formed and are dispersed in extraction and stripping cells where simultaneous extraction and stripping occurs. The process can be viewed as simultaneous counter current extraction and stripping. The aqueous drops coalesce in the settlers at the bottom of the reactor and are removed continuously. Steady state mass transport model proposed for ESPLIM system accounts for the vertical counter-current extraction and stripping processes taking place in the extraction and stripping cells, together with the lateral transport process of the metal-complex and carrier across the two cells through the integrated baffle zone. The model equations were solved analytically to obtain concentration profiles as a function of the height of the reactor. The required parameters such as mass transfer coefficients, diffusion coefficients etc. were estimated using different correlations. Model predictions agreed remarkably well with the experimental data under various process conditions. From this investigation, it was found that ESPLIM is a simple, efficient and economical process and can be applied in a variety of situations. Based on a suitable combination of solvent extraction, dispersion and liquid membrane technique, a new type of separation system called " Unified Liquid Membrane " was developed. The ULM unit was designed and fabricated, and experiments were conducted to evaluate its performance. The ULM is basically derived from ESPLIM by changing the reactor, baffle design and dispersion technique. Aqueous feed and strip phases were atomized using compressed air through a fine nozzle and are dispersed on either side of an integrated baffle plate that divides the reactor into extraction and stripping cells. Tapering bottom of the reactor reduces the dead volume of the liquid in the settlers and the baffle plate remarkably reduces the leakage problem as well as the resistance through the baffle. Experiments were conducted using LIX 64N and Alamine 336 as carriers for copper and chromium and / or zinc. Mass transport model proposed considers both chemical and phase equilibria in extraction and stripping cells, vertical and lateral transport of carrier and complex across the extraction and stripping cells through the baffle zone. The model equations were solved using initial conditions at the top of the reactor, and equilibrium data for extraction and stripping cells. Effect of various experimental conditions and process parameters was simulated using this model and the model predictions are found to be in excellent agreement with the experimental data. The ULM system developed in this investigation overcomes the major limitations encountered with the other types of liquid membranes while retaining all the advantages of this technology. The problem of high mass transfer resistance from bulk phase to metal permeation as in the case of BLM was eliminated by good phase dispersion. Additional resistance to mass transport from solid membrane as in the case of SLM was removed by using an integrated baffle which also avoids problems of membrane instability, pore clogging and selectivity. The complex problems of emulsification and demulsification were completely eliminated making the system much simpler and efficient. Very good phase dispersion was obtained by atomization without the need for either stirring the whole system or application of high electrical field in the reactor. The membrane liquid within the integrated baffle elements allows easy transport of different species between extraction and stripping cells while completely preventing the mixing of the two aqueous phases. The problems of leakage, swelling and occlusion were avoided due to very short residence time of the aqueous drops in the reactor. It was found that the new ULM configuration is simple, elegant, highly efficient and superior to the other types of liquid membrane systems.

Page generated in 0.0676 seconds