• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 9
  • 9
  • 1
  • 1
  • 1
  • Tagged with
  • 56
  • 56
  • 14
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Experimental study of thermosiphon performance

Sivanagere, Sumeeth S. January 2002 (has links)
Thesis (M.S.)--West Virginia University, 2002. / Title from document title page. Document formatted into pages; contains vii, 66 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 29).
22

Design of a clamp-on ultrasonic flow meter for wet gas pipelines

Vedapuri, Damodaran. January 2001 (has links)
Thesis (Ph. D.)--Ohio University, June, 2001. / Title from PDF t.p. Includes bibliographical references (leaves 191-193).
23

Development of multiphase flow metering set-up utilizing coriolis meters

Al-Taweel, Ahmed Baqer. January 1997 (has links) (PDF)
Thesis (M.S.)--King Fahd University of Petroleum and Minerals, 1997 / Title from document title page. Includes bibliographical references. Available in PDF format via the World Wide Web.
24

Development & application of a field instrumentation system for the investigation of surf zone hydrodynamics /

Greer, Matthew Noble. January 1980 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology and Woods Hole Oceanographic Institute, 1979. / Grant no.: 04-7-158-44079. Photocopy of typescript. Bibliography: p. 142-144.
25

Medição de vazão em tubos de pequeno diâmetro utilizando orifícios integrais

Filardi, Marcelo [UNESP] 05 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-05Bitstream added on 2014-06-13T19:09:38Z : No. of bitstreams: 1 filardi_m_me_ilha.pdf: 7008979 bytes, checksum: eba937cf230e2e2361031743f60bdbb2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Orifício integral é um medidor de vazão industrial útil para as linhas de pequeno diâmetro (tipicamente até 38 mm), que permite um alinhamento muito preciso do conjunto. No presente trabalho, foram realizados vários experimentos utilizando orifícios integrais em tubos de PVC de 1⁄2 polegada, para verificar a influência da rugosidade do tubo, da excentricidade do furo e da geometria do orifício nas medições de vazão. Experimentos adicionais foram feitos para verificar influências de fabricação e a interferência da rugosidade do tubo sobre a operação do equipamento. Os coeficientes de descarga foram obtidos em função do número de Reynolds e, posteriormente, comparados entre si e com a literatura (fabricantes e normas). Os resultados mostraram que os orificios concêntricos com borda em canto vivo permitem operação em uma ampla faixa de Reynolds, além de apresentarem um processo de produção mais barato e uma boa precisão. Uma equação representativa do coeficiente de descarga foi proposta para este tipo de placa / Integral orifice is an industrial flowmeter useful for small diameter lines (typically up to 38 mm), which provides a very precise alignment. In the present work, experiments have been performed using integral orifices in 1⁄2 inch PVC pipes, in order to check the influence of the tube roughness, the eccentricity of the hole and orifice geometry in the flow measurements. Additional experiments have been carried out to verify the influence of the manufacturing process and the roughness in tubes on the equipment operation. Discharge coefficients have been obtained for the different orifices as a function of the Reynolds number. Results have been compared to each other and with data from the literature (manufacturers and standards). Results show that concentric plates with square edge permit operation in a wide Reynolds number range, allied a cheaper manufacturing process and a good accuracy. A representative equation for the discharge coefficient of such a plate has been determined
26

Caracterização das flutuações do sinal doppler do fluxo microvascular / Characterization of laser doppler signal fluctuations in microvascular flow

FOLGOSI CORREA, MELISSA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:05Z (GMT). No. of bitstreams: 0 / Tese (Doutoramento) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
27

Medição de vazão em tubos de pequeno diâmetro utilizando orifícios integrais /

Filardi, Marcelo. January 2012 (has links)
Orientador: Sérgio Said Mansur / Coorientador: Edson Del Rio Vieira / Banca: João Batista Campos Silva / Banca: Vicente Luiz Scalon / Resumo: Orifício integral é um medidor de vazão industrial útil para as linhas de pequeno diâmetro (tipicamente até 38 mm), que permite um alinhamento muito preciso do conjunto. No presente trabalho, foram realizados vários experimentos utilizando orifícios integrais em tubos de PVC de 1⁄2 polegada, para verificar a influência da rugosidade do tubo, da excentricidade do furo e da geometria do orifício nas medições de vazão. Experimentos adicionais foram feitos para verificar influências de fabricação e a interferência da rugosidade do tubo sobre a operação do equipamento. Os coeficientes de descarga foram obtidos em função do número de Reynolds e, posteriormente, comparados entre si e com a literatura (fabricantes e normas). Os resultados mostraram que os orificios concêntricos com borda em canto vivo permitem operação em uma ampla faixa de Reynolds, além de apresentarem um processo de produção mais barato e uma boa precisão. Uma equação representativa do coeficiente de descarga foi proposta para este tipo de placa / Abstract: Integral orifice is an industrial flowmeter useful for small diameter lines (typically up to 38 mm), which provides a very precise alignment. In the present work, experiments have been performed using integral orifices in 1⁄2 inch PVC pipes, in order to check the influence of the tube roughness, the eccentricity of the hole and orifice geometry in the flow measurements. Additional experiments have been carried out to verify the influence of the manufacturing process and the roughness in tubes on the equipment operation. Discharge coefficients have been obtained for the different orifices as a function of the Reynolds number. Results have been compared to each other and with data from the literature (manufacturers and standards). Results show that concentric plates with square edge permit operation in a wide Reynolds number range, allied a cheaper manufacturing process and a good accuracy. A representative equation for the discharge coefficient of such a plate has been determined / Mestre
28

Frequency Response Characteristics Of Respiratory Flow-meters

January 2013 (has links)
abstract: Flow measurement has always been one of the most critical processes in many industrial and clinical applications. The dynamic behavior of flow helps to define the state of a process. An industrial example would be that in an aircraft, where the rate of airflow passing the aircraft is used to determine the speed of the plane. A clinical example would be that the flow of a patient's breath which could help determine the state of the patient's lungs. This project is focused on the flow-meter that are used for airflow measurement in human lungs. In order to do these measurements, resistive-type flow-meters are commonly used in respiratory measurement systems. This method consists of passing the respiratory flow through a fluid resistive component, while measuring the resulting pressure drop, which is linearly related to volumetric flow rate. These types of flow-meters typically have a low frequency response but are adequate for most applications, including spirometry and respiration monitoring. In the case of lung parameter estimation methods, such as the Quick Obstruction Method, it becomes important to have a higher frequency response in the flow-meter so that the high frequency components in the flow are measurable. The following three types of flow-meters were: a. Capillary type b. Screen Pneumotach type c. Square Edge orifice type To measure the frequency response, a sinusoidal flow is generated with a small speaker and passed through the flow-meter that is connected to a large, rigid container. True flow is proportional to the derivative of the pressure inside the container. True flow is then compared with the measured flow, which is proportional to the pressure drop across the flow-meter. In order to do the characterization, two LabVIEW data acquisition programs have been developed, one for transducer calibration, and another one that records flow and pressure data for frequency response testing of the flow-meter. In addition, a model that explains the behavior exhibited by the flow-meter has been proposed and simulated. This model contains a fluid resistor and inductor in series. The final step in this project was to approximate the frequency response data to the developed model expressed as a transfer function. / Dissertation/Thesis / M.S.Tech Electrical Engineering 2013
29

Caracterização das flutuações do sinal doppler do fluxo microvascular / Characterization of laser doppler signal fluctuations in microvascular flow

FOLGOSI CORREA, MELISSA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:05Z (GMT). No. of bitstreams: 0 / O sinal de fluxo cutâneo obtido via fluxometria Laser Doppler (SFLD) tem flutuações de baixas frequências que estão relacionadas a mecanismos de controle do fluxo microvascular. Análises espectrais, via transformada de Fourier e transformada de wavelet, têm sido usadas para correlacionar as flutuações de SFLD com os seguintes mecanismos de controle de fluxo: metabólico, metabólico NO-dependente, neurogênico e miogênico, nos respectivos intervalos de frequência 0,005-0,0095 Hz, 0,0095-0,02 Hz, 0,02-0,05 Hz e 0,05-0,15 Hz. A potência do sinal, em cada intervalo de frequência, geralmente é usada como uma medida da atividade do mecanismo de controle microvascular relacionado. Uma vez que os métodos usados de análise são espectrais, as características das flutuações do SFLD, em cada intervalo de frequência, no domínio do tempo são desconhecidas. Como consequência, há ausência de critérios objetivos para medir adequadamente, em cada intervalo de frequência, os parâmetros hemodinâmicos relacionados. O objetivo deste trabalho foi caracterizar e quantificar flutuações temporais, espaciais e espaço-temporais do SFLD em cada faixa de frequência, usando um método no domínio do tempo. Os fluxos basais (320C) e termicamente estimulados à (420C) das regiões volares de antebraços de 20 voluntários saudáveis foram coletados em duas regiões próximas e analisados. As análises dos dados obtidos indicam que janelas temporais pequenas (1 minuto) são aceitáveis para a quantificação do fluxo médio, e que janelas temporais maiores são necessários para quantificar as flutuações de fluxo. A análise espaço-temporal revelou uma forte correlação entre sinais (em todas as bandas, exceto na banda B5) das duas regiões investigadas, durante longos intervalos de tempo, quando as duas regiões estudadas foram termicamente estimuladas, e menor variabilidade intragrupo quando comparada à obtida para os valores médios das flutuações, sugerindo que o intervalo de tempo de correlação é um parâmetro promissor para estudar mecanismos de controle do fluxo microvascular. / Tese (Doutoramento) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
30

Development of a calcium carbonate scale formation experimental set-up for the evaluation of physical water treatment devices

Da Veiga, Reinaldo 19 November 2008 (has links)
D.Ing.

Page generated in 0.2311 seconds