• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] HOLMIUM-166M: MULTI-GAMA STANDARD TO DETERMINE THE ACTIVITY OF RADIONUCLIDES IN SEMICONDUCTOR DETECTORS. / [es] HOLMIO-166M: PADRÓN MULTI-GAMMA PARA LA DETERMINACIÓN DE ACTIVIDAD DE RADIONUCLÍDEOS / [pt] HÓLMIO-166M: PADRÃO MULTI-GAMA PARA A DETERMINAÇÃO DE ATIVIDADE DE RADIONUCLÍDEOS POR MEIO DE DETECTORES SEMICONDUTORES

ESTELA MARIA DE OLIVEIRA BERNARDES 16 October 2001 (has links)
[pt] Para estabelecer com exatidão as curvas em eficiência de detectores a germânio, usam-se radionuclídeos que possuem decaimento complexo, como o 152 Eu e 133 Ba. Porém, por possuírem poucas linhas gama de boa intensidade e irregularmente distribuídas no espectro, esses radionuclídeos não podem ser usados sozinhos. Para superar tais dificuldades, o 166m Ho mostra-se conveniente como padrão único destinado à calibração em eficiência dos espectrômetros a germânio, pois decai por emissão b - , com emissões subseqüentes de 40 linhas gama intensas e bem distribuídas entre 80 e 1500 keV. Além disso, sua longa meia-vida (1200 anos) e raios X característicos entre 40 e 50 keV, o tornam um padrão excelente para calibração de detectores de germânio. É preciso, no entanto, conhecer com exatidão as probabilidades de emissão de fótons de suas principais linhas, uma vez que a literatura tem apresentado estes valores com discrepâncias. Neste trabalho é proposta uma metodologia para determinar, com rigor metrológico, a probabilidade de emissão de suas principais linhas, por meio do uso combinado de espectrometria gama e técnicas de coincidência (4pb-g ). Os resultados experimentais apresentaram-se convergentes em relação aos dados de outros autores, com incertezas menores ou compatíveis. / [en] The efficiency and calibration curves as function of gamma- ray energy for a germanium detector are usually established by using many standard gamma-ray sources of radionuclides decaying with few gamma rays or radionuclides having complex decay scheme, as 152 Eu or 133 Ba. But these radionuclides cannot be used alone, because they have a few gamma lines with high intensity and these lines have a irregular distribution in the energy spectrum. 166m Ho is found to be a convenient single source for such calibration, because it decays by b - with subsequent emission of about 40 strong and well distributed gamma lines between 80 and 1500 keV. Moreover, its long half - life (1200 years) and X-rays characteristics between 40 and 50 keV makes it a good standard for calibration of germanium detectors. However, it is necessary to know with accuracy and precision the gamma ray intensities of their main lines, due to the fact that literature has showed discrepant values. Then, a methodology to determine the emission probability of its main lines is proposed by means of combined use of gamma spectrometry and coincidence 4pb - g techniques. The experimental results show consistence to the others authors, with lower or compatible uncertainties. / [es] Para estabelecer con exactitud las curvas en eficiencia de detectores la germánio, se utilizan radionuclídeos que poseen decaimiento complejo, como el 152 Eu y 133 Ba. Sin embargo, como poseen pocas líneas gama de buena intensidad y irregularmente distribuidas en el espectro, esos radionúcleos no pueden ser usados separadamente. Para superar tales dificuldades, el 166m Ho muestra se conveniente como padrón único destinado a la calibración en eficiencia de los espectrómetros la germánio, pues decae por emisión b , con emisiones subsecuentes de 40 líneas gama intensas y bien distribuidas entre 80 y 1500 keV. Además, su larga media vida (1200 anos) y rayos X característicos entre 40 y 50 keV, el tornan un padrón excelente para calibración de detectores de germanio. Es preciso conocer con exactitud las probabilidades de emisión de fóptons de sus principales líneas, una vez que la literatura ha presentado estos valores con discrepancias. En este trabajo se propone una metodología para determinar, con rigor metrológico, la probabilidad de emisión de sus principales líneas, por medio del uso combinado de espectrometría gama y técnicas de coincidencia (4pb g ). Los resultados experimentales presentaran se convergentes en relación a los datos de otros autores, con incertezas menores o compatibles.
2

Magnetic Spectrometer Calibration for Gamma-Ray Intensities

Staveley, Anne 10 1900 (has links)
A study has been made of the external conversion spectrum of gamma-rays of less than 200 kev. A set of semi-empirical curves relating the photoelectric peak height to the gamma-ray intensity has been established using antimony radiators. These results will be discussed. A method of preparing thin beta sources will also be described. / Thesis / Master of Science (MSc)

Page generated in 0.0491 seconds