Spelling suggestions: "subject:"[een] HYDROLYSIS DEGRADATION"" "subject:"[enn] HYDROLYSIS DEGRADATION""
1 |
Nanofibras de poli(ε-caprolactona) e poli(óxido de etileno): fabricação pela técnica de eletrofiação e efeitos radiolíticosGONÇALVES, Gonçalves 28 August 2015 (has links)
Submitted by Fabio Sobreira Campos da Costa (fabio.sobreira@ufpe.br) on 2016-04-19T11:42:18Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Natércia Antunes Gonçalves.pdf: 4208190 bytes, checksum: b60c1953389fb9ccc50987db955906d5 (MD5) / Made available in DSpace on 2016-04-19T11:42:19Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Dissertação Natércia Antunes Gonçalves.pdf: 4208190 bytes, checksum: b60c1953389fb9ccc50987db955906d5 (MD5)
Previous issue date: 2015-08-28 / FACEPE / O poli(ε-caprolactona) (PCL) é um poliéster biocompatível, biodegradável e
semicristalino utilizado na confecção de artefatos médico-farmacêuticos, especialmente
como suporte para cultivo de células e tecidos. Por outro lado, sua hidrofobicidade e
baixas taxas de hidrólise in vivo impedem a expansão do uso destes polímeros em
aplicações biológicas. Nesta pesquisa, empregamos três estratégias na tentativa de
aumentar a taxa de hidrólise da PCL: a) preparação do material em morfologia fibrilar,
para aumentar a superfície de contato com o meio; b) irradiação com raios gama, para
induzir dano molecular e acelerar a hidrólise; e c) blenda com o polímero hidrofílico e
lixiviável poli(óxido de etileno) (PEO), para aumentar a molhabilidade e permitir maior
percolação da água. Tapetes de PCL, apresentando nanofibras com diâmetros menores
que 100nm e de microfibras com diâmetros entre 1,9 e 7,5μm da blenda PCL/PEO 10%
m/m foram preparados pela técnica de eletrofiação, irradiados com raios gama em doses
de 25 e 50kGy e submetidos à hidrólise por submersão em tampão fosfato salino (PBS)
pH 7,4 a 37 0C. Para comparação, filmes de PCL e da blenda de PCL/PEO foram
confeccionados por derrame em solução (film casting) e submetidos ao mesmo
tratamento. Nada se pode afirmar sobre as mudanças de Massa Molar Viscosimétrica
Média (Mv) em filmes de PCL irradiados, pois não foi possível observar nem o efeito
de cisão, nem reticulação da cadeia principal. A irradiação gama não influenciou nas
propriedades térmicas dos filmes de PCL e os cálculos de energia de ativação para
reações de decomposição térmica evidenciaram que filmes de PCL têm boa estabilidade
térmica. Ensaios espectrométricos no Infravermelho com Transformada de Fourier
(FTIR) e difratométricos de raios X dos filmes de PCL não foi possível observar
mudanças significativas de estrutura molecular ou cristalinidade com a irradiação gama.
As estratégias adotadas para melhorar a degradação hidrolítica do PCL funcionaram.
Blendas de PCL/PEO (10% m/m) apresentaram taxa de degradação hidrolítica maiores
do que as amostras de PCL, tanto na forma de tapetes microfibrilares eletrofiados como
na forma de filmes espessos. Sendo a primeira com taxa de degradação mais acentuada.
A irradiação gama exerce influência significativa na degradação hidrolítica apenas em
blendas PCL/PEO na forma de filmes. A degradação hidrolítica dos filmes de PCL se
mostrou muito lenta, não sendo possível observar diferenças significativas entre
amostras irradiadas e não irradiadas. / Poly (ε-caprolactone) (PCL) is a biocompatible, biodegradable, semicrystalline
polyester used in medical-pharmaceutical devices, specially as scaffolds in cell and
tissue culture. Nevertheless, its hydrophobicity and low in vivo hydrolysis rates are
obstacles to the expansion of its use in biological applications. In this work, we
designed three strategies to address PCL hydrophobicity issues: a)prepare electrospun
fibers to enhace contact surface with aqueous media; b)irradiation with gamma rays to
induce molecular damage and increase hydrolysis rate; and c) blending with the
hydrophilic, leacheble polymer poly(ethylene oxide) (PEO), in order to increase
wettability and allow larger water percolation rates. Mats of PCL electrospun nanofiber
with less than 100nm in diameter; and of electrospun PCL/PEO (10%wt) blend
microfibers presenting diameters in the range of 1.9 - 7.5 μm were irradiated with
gamma rays in 25 and 50 kGy dose and submitted to in vitro hydrolysis in phosphatebuffered
saline (PBS) solution, pH 7,4 at 37 0C. PCL and PCL/PEO (10%wt) films were
also prepared by film casting and treated in the same way, for comparison. Nothing can
be said about mass changes Viscosity Average Molar Mass (Mv) in irradiated PCL
films because it was not possible to observe nor the effect of spin-off, or crosslinking of
the backbone. Good thermal stability was also evidenced by calculations of activation
energy for thermal degradation of PCL. Fourier Transform Infrared espectrometry and
X-ray difractometry data did not evidence significant changes in molecular structure or
crystallitiny of PCL after irradiation.
Strategies to improve PCL in vitro hydrolysis degradation rate were successful. Blends
of PCL/PEO (10% wt) presented higher hydrolysis rates than PCL samples, either in
mat fibers or film forms. Hydrolysis degradation of PCL films was very slow, and no
differences between non irradiated or irradiated samples were observed.
|
2 |
[pt] EFEITO DA DEGRADAÇÃO POR HIDRÓLISE NA QUANTIFICAÇÃO DA POLIACRILAMIDA SULFONADA POR SEC-UV / [en] EFFECT OF HYDROLYSIS DEGRADATION ON THE QUANTIFICATION OF SULFONATED POLYACRYLAMIDE BY SEC-UVCECILIA CAVALCANTI R GONCALVES 18 February 2025 (has links)
[pt] A quantificação da poliacrilamida sulfonada (PAM-AMPS) por cromatografia de
exclusão de tamanho com detecção ultravioleta (SEC-UV) é amplamente utilizada
para monitorar processos de recuperação avançada de petróleo (EOR) e o descarte
de água. No entanto, não é discutido na literatura como a degradação por hidrólise
durante o processo de produção pode afetar o método de monitoramento da
concentração do polímero. Assim, este trabalho tem como objetivo avaliar o efeito
da degradação por hidrólise da PAM-AMPS em sua quantificação por SEC-UV.
Para isso, foi desenvolvido um método de degradação acelerada de hidrólise
controlada. Padrões de HPAM-AMPS com diferentes graus de hidrólise (HD = 7 –
33 por cento) foram obtidos. Diferentes métodos de determinação de HD (RMN de 13C,
FTIR e retrotitulação) foram avaliados e se mostraram estatisticamente iguais. A
quantificação feita por SEC-UV mostrou que a sensibilidade do método é
dependente do HD. Erros entre 20 por cento e 40 por cento foram observados a partir de 13 por cento de
HD, mas foram irrelevantes até 10 por cento. Esses valores diminuíram com o aumento da
concentração do polímero. Os resultados indicam que existem dois fatores
compensatórios para a diminuição da absortividade molar devido à substituição de
amida por carboxilato: o grupo sulfonato atuando como um cromóforo adicional e
um deslocamento para o vermelho nos espectros de absorção devido à formação de
ligações de hidrogênio em concentrações mais altas. Assim, este estudo mostra que
o aumento da concentração nesse tipo de poliacrilamida sulfonada pode reduzir os
erros de quantificação ao minimizar o efeito do HD em amostras aquosas complexas
sujeitas à degradação química, destacando a importância de determinar o grau de
hidrólise para uma quantificação precisa de PAM-AMPS por SEC-UV. / [en] The quantification of sulfonated polyacrylamide (PAM-AMPS) by size exclusionchromatography with ultraviolet detection (SEC-UV) is widely used to monitorenhanced oil recovery (EOR) processes and water disposal. However, the literaturedoes not provide information on how hydrolysis degradation during the productionprocess can affect the method for monitoring polymer concentration. Thus, thiswork aims to evaluate the effect of hydrolysis degradation of PAM-AMPS on itsquantification by SEC-UV. For this purpose, an accelerated controlled hydrolysisdegradation method was developed. PAM-AMPS standards with different degreesof hydrolysis (HD = 7 – 33 percent) were obtained. Different methods for determiningHD (13C NMR, FTIR, and back titration) were evaluated and found to bestatistically equivalent. Quantification by SEC-UV showed that the method ssensitivity depends on the degree of hydrolysis. Errors ranged from 20 percent to 40 percent starting at 13 percent HD but were negligible below 10 percent HD. These values decreased with increasing polymer concentration. The results indicate two compensatoryfactors for the decrease in molar absorptivity due to the substitution of amide bycarboxylate: the sulfonate group acting as an additional chromophore and a red shiftin the absorption spectra due to hydrogen bonding at higher concentrations. Thus,this study demonstrates that increasing the concentration of this type of sulfonatedpolyacrylamide can reduce quantification errors by minimizing the effect of HD incomplex aqueous samples subject to chemical degradation, highlighting theimportance of determining the degree of hydrolysis for accurate PAM-AMPSquantification by SEC-UV.
|
Page generated in 0.0333 seconds