• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 257
  • 194
  • 34
  • 19
  • 16
  • 14
  • 12
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • Tagged with
  • 617
  • 199
  • 164
  • 121
  • 87
  • 51
  • 46
  • 37
  • 35
  • 32
  • 30
  • 30
  • 27
  • 26
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Occlusal stability following occlusal adjustment a stereophotogrammetric study : a thesis submitted in partial fulfillment ... periodontics ... /

Vale, Jose D. Freitas. January 1970 (has links)
Thesis (M.S.)--University of Michigan, 1970. / eContent provider-neutral record in process. Description based on print version record.
92

The effect of canine guidance angulation on mandibular movements a thesis submitted in partial fulfillment ... prosthodontics and restorative dentistry, crown and bridge ... /

Shea, Joseph Frederick. January 1989 (has links)
Thesis (M.S.)--University of Michigan, 1989.
93

Occlusal study of Armenian speaking people a thesis submitted in partial fulfillment ... in orthodontics ... /

Bieler, Warren. Gregory, Sirak K. Jacobsen, W. Manfred January 1948 (has links)
Thesis (M.S.)--University of Michigan, 1948.
94

A cephalometric analysis of mandibular postural change between rest position and occlusion thesis submitted as partial fulfillment ... orthodontics ... /

Vedder, Robert L. January 1956 (has links)
Thesis (M.S.)--University of Michigan, 1956.
95

Die Stellungsanomalien der Weisheitszähne bei den Konstitutionstypen Inaugural-Dissertation /

Sepp, Josef, January 1935 (has links)
Thesis (doctoral)--Ludwig-Maximilians-Universität, Munich, 1932.
96

Periotestwerte und Okklusion im gesunden Gebiss

Wagner, Michael, January 1988 (has links)
Thesis (doctoral)--Eberhards-Karls-Universität Tübingen, 1988.
97

Central retinal vein occlusion certain risk factors, electroretinography and an experimental treatment model /

Larsson, Jörgen. January 1998 (has links)
Thesis (doctoral)--Lund University, 1998. / Added t.p. with thesis statement inserted. Includes bibliographical references.
98

Periotestwerte und Okklusion im gesunden Gebiss

Wagner, Michael, January 1988 (has links)
Thesis (doctoral)--Eberhards-Karls-Universität Tübingen, 1988.
99

Consistency of near-infrared spectroscopy chromophores during a 10-minute vascular occlusion procedure of the thigh over 5 consecutive days

Mackintosh, Cameron Eve 07 July 2016 (has links)
The purpose of this study was to examine the consistency of near-infrared spectroscopy (NIRS) measures associated with a 10 minute vascular occlusion of the thigh during 5 consecutive days. A secondary purpose was to examine if the repeated daily occlusions modify the vascular response to such occlusions. The NIRS chromophores of oxygenated hemoglobin (HbO2), deoxygenated hemoglobin (HHb), total hemoglobin (tHb), hemoglobin difference (HbDiff), and total saturation index (TSI) were monitored at the vastus lateralis muscle during each testing session. Participants were female (age 18-30 yrs) and were randomly assigned to one of two groups. The Test Group (age 23 ± 2yrs) completed an occlusion test every day for 5 consecutive days while the Control Group (age 21 ±1.6yrs) was tested on days 1, 3 and 5. Each testing session involved 10 minutes rest in a supine position, 10 minutes of femoral artery occlusion (preset at 250mmHg), 10 minutes of recovery. At onset of occlusion, the rapid cuff inflation system inflated in 0.3 seconds to the preset 250mmHg. Following the 10 minutes of occlusion, the cuff was deflated in 0.3 seconds. Heart rate was monitored throughout all testing sessions and mean arterial pressure was calculated and compared between groups. There were no significant group or day main effects found, nor any significant interactions for the following hemoglobin chromophores measures: HbO2, HHb, HbDiff, and TSI. In all participants, the NIRS response pattern to rest, occlusion and recovery was consistent for all testing days regardless of group. The response pattern to the occlusion initiated by the rapid cuff inflation was as follows: HbO2, tHb, HbDiff, and TSI decreased then slowly plateaued over the 10 minutes while HHb increased initially and then plateaued. Following the rapid cuff deflation, HbO2, tHb, HbDiff and TSI increased to their maximum reperfusion levels and then plateaued over the remainder of the 10 minutes of recovery. During that same period, HHb decreased initially upon reperfusion and then plateaued. Unlike the other measures, TSI and tHb demonstrated inconsistencies in their response pattern regardless of group or day. The consistency of hemoglobin chromophores response pattern to daily 10 minute vascular leg occlusions over 5 consecutive days is an important finding of this study. This response indicates that there is no apparent change in vascular response to repeated occlusions and has implications for exercise studies that use occlusion in their methodology. The study also emphasizes the inconsistency of tHb and TSI as primary hemoglobin response measures to occlusion. Similarly, the results demonstrate the potential misinterpretation of results if only relying on one hemoglobin measure during occlusion. / Graduate
100

Clinical evaluation of fixation characteristics and visual acuity outcomes in human amblyopia

Cleary, Marie January 2002 (has links)
No description available.

Page generated in 0.0368 seconds