• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 20
  • 6
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 88
  • 88
  • 23
  • 15
  • 11
  • 11
  • 9
  • 8
  • 8
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Chromatic modulation systems for multiparameter measurement in physically demanding environments

Henderson, Philip James January 1989 (has links)
No description available.
2

Optical sensors for process control using fibre optic links : Digital and self-referencing systems

Philp, G. S. January 1984 (has links)
No description available.
3

Evaluation of palladium optical coatings for hydrogen sensing

Nabeerasool, Mohammed Akmez January 2012 (has links)
This thesis describes the development and characterisation of palladium optical coatings for hydrogen sensing. The main aim of the thesis was to optimise an optically interrogated palladium coated substrate to detect hydrogen at concentrations less than 1% in humid conditions (50-80%). An optical set up was constructed to investigate the change in the coatings in transmission at 650 nm on exposure to varying hydrogen concentrations in dry and wet conditions. Three different optical substrates; Polymer Optical Fibre (POF), Polymethyl methacrylate (PMMA) and glass were evaluated to determine the best support for palladium; criteria of selection were based on hydrogen detection performance in dry and humid condition (50%). PMMA was shown to be the ideal support as effect of humidity on hydrogen detection was minimal. Palladium was deposited by sputter coating technique and the coating thickness demonstrates a dependence on the deposition time and position of the substrate inside the coating chamber. The coating developed showed a response time of 1s at 5%H2, a detection range of 0-9.1% with a demonstrated detection limit of 200 parts per million (ppm) and a predicted limit of detection of 15 ppm. The rate of hydrogen detection was proposed to be diffusion limited for coating thickness up to the threshold thickness. At thicknesses less than the threshold thickness, the rate limiting step was related to the binding force between the coating and the support. The coating performance was unaffected by cross sensitive gases such as hydrogen sulphide, carbon monoxide, methane and ethene. In the presence of Relative Humidity (50-80%), the coating reached a limit of detection at 0.1% H2. However, over exposure to humidity lead to temperature effect which was compensated using a temperature compensation model developed. The surface of the coating developed was characterised by Atomic Force Microscopy (AFM), X-Ray Diffraction (XRD) and X-Ray Photoelectron Spectroscopy (XPS) and revealed that the coating developed is unaffected by the tests carried out through the PhD.
4

Arrays of Silicon P-i-N Nanowires for Antenna-enhanced and Polarisation Sensitive Detection of Light

Stewart, Corey 28 November 2013 (has links)
A novel antenna effect is demonstrated in arrays of 500, 200 and 100 silicon nanowires embedded in silicon dioxide. The gratings are analyzed using spectral and polarisation resolved photocurrent microscopy. Resonant enhancements in the electric field and photocurrent response are observed at multiple wavelengths corresponding to coupling of incident radiation into the grating's multiple-scattering electromagnetic modes. The photoresponse retains the sinusoidal polarisation anisotropy expected in single nanowires. The resonances are modeled using electromagnetic scattering theory and show excellent agreement with measurement. An experimental quality factor of Q=10 was measured for the gratings, exceeding that of a single wire, but lower than expected from theory. The difference is ascribed to the finite length of the wires and their termination at ohmic contacts. Strategies to improve Q are discussed, and a grating is presented to resonantly enhance light detection at red, green and blue wavelengths for application as a colour imaging sensor.
5

Arrays of Silicon P-i-N Nanowires for Antenna-enhanced and Polarisation Sensitive Detection of Light

Stewart, Corey 28 November 2013 (has links)
A novel antenna effect is demonstrated in arrays of 500, 200 and 100 silicon nanowires embedded in silicon dioxide. The gratings are analyzed using spectral and polarisation resolved photocurrent microscopy. Resonant enhancements in the electric field and photocurrent response are observed at multiple wavelengths corresponding to coupling of incident radiation into the grating's multiple-scattering electromagnetic modes. The photoresponse retains the sinusoidal polarisation anisotropy expected in single nanowires. The resonances are modeled using electromagnetic scattering theory and show excellent agreement with measurement. An experimental quality factor of Q=10 was measured for the gratings, exceeding that of a single wire, but lower than expected from theory. The difference is ascribed to the finite length of the wires and their termination at ohmic contacts. Strategies to improve Q are discussed, and a grating is presented to resonantly enhance light detection at red, green and blue wavelengths for application as a colour imaging sensor.
6

Development of sensor-based nitrogen recommendation algorithms for cereal crops

Asebedo, Antonio Ray January 1900 (has links)
Doctor of Philosophy / Department of Agronomy / David B. Mengel / Nitrogen (N) management is one of the most recognizable components of farming both within and outside the world of agriculture. Interest over the past decade has greatly increased in improving N management systems in corn (Zea mays) and winter wheat (Triticum aestivum) to have high NUE, high yield, and be environmentally sustainable. Nine winter wheat experiments were conducted across seven locations from 2011 through 2013. The objectives of this study were to evaluate the impacts of fall-winter, Feekes 4, Feekes 7, and Feekes 9 N applications on winter wheat grain yield, grain protein, and total grain N uptake. Nitrogen treatments were applied as single or split applications in the fall-winter, and top-dressed in the spring at Feekes 4, Feekes 7, and Feekes 9 with applied N rates ranging from 0 to 134 kg ha[superscript]-1. Results indicate that Feekes 7 and 9 N applications provide more optimal combinations of grain yield, grain protein levels, and fertilizer N recovered in the grain when compared to comparable rates of N applied in the fall-winter or at Feekes 4. Winter wheat N management studies from 2006 through 2013 were utilized to develop sensor-based N recommendation algorithms for winter wheat in Kansas. Algorithm RosieKat v.2.6 was designed for multiple N application strategies and utilized N reference strips for establishing N response potential. Algorithm NRS v1.5 addressed single top-dress N applications and does not require a N reference strip. In 2013, field validations of both algorithms were conducted at eight locations across Kansas. Results show algorithm RK v2.6 consistently provided highly efficient N recommendations for improving NUE, while achieving high grain yield and grain protein. Without the use of the N reference strip, NRS v1.5 performed statistically equal to the KSU soil test N recommendation in regards to grain yield but with lower applied N rates. Six corn N fertigation experiments were conducted at KSU irrigated experiment fields from 2012 through 2014 to evaluate the previously developed KSU sensor-based N recommendation algorithm in corn N fertigation systems. Results indicate that the current KSU corn algorithm was effective at achieving high yields, but has the tendency to overestimate N requirements. To optimize sensor-based N recommendations for N fertigation systems, algorithms must be specifically designed for these systems to take advantage of their full capabilities, thus allowing implementation of high NUE N management systems.
7

Chip Scale Integrated Optical Sensing Systems with Digital Microfluidic Systems

Luan, Lin January 2010 (has links)
<p>Data acquisition and diagnostics for chemical and biological analytes are critical to medicine, security, and the environment. Miniaturized and portable sensing systems are especially important for medical and environmental diagnostics and monitoring applications. Chip scale integrated planar photonic sensing systems that can combine optical, electrical and fluidic functions are especially attractive to address sensing applications, because of their high sensitivity, compactness, high surface specificity after surface customization, and easy patterning for reagents. The purpose of this dissertation research is to make progress toward a chip scale integrated sensing system that realizes a high functionality optical system integration with a digital microfluidics platform for medical diagnostics and environmental monitoring. </p><p>This thesis describes the details of the design, fabrication, experimental measurement, and theoretical modeling of chip scale optical sensing systems integrated with electrowetting-on-dielectric digital microfluidic systems. Heterogeneous integration, a technology that integrates multiple optical thin film semiconductor devices onto arbitrary host substrates, has been utilized for this thesis. Three different integrated sensing systems were explored and realized. First, an integrated optical sensor based upon the heterogeneous integration of an InGaAs thin film photodetector with a digital microfluidic system was demonstrated. This integrated sensing system detected the chemiluminescent signals generated by a pyrogallol droplet solution mixed with H2O2 delivered by the digital microfluidic system. </p><p>Second, polymer microresonator sensors were explored. Polymer microresonators are useful components for chip scale integrated sensing because they can be integrated in a planar format using standard semiconductor manufacturing technologies. Therefore, as a second step, chip scale optical microdisk/ring sensors integrated with digital microfluidic systems were fabricated and measured. . The response of the microdisk and microring sensing systems to the change index of refraction, due to the glucose solutions in different concentrations presented by the digital microfluidic to the resonator surface, were measured to be 95 nm/RIU and 87nm/RIU, respectively. This is a first step toward chip-scale, low power, fully portable integrated sensing systems. </p><p>Third, a chip scale sensing system, which is composed of a planar integrated optical microdisk resonator and a thin film InGaAs photodetector, integrated with a digital microfluidic system, was fabricated and experimentally characterized. The measured sensitivity of this sensing system was 69 nm/RIU. Estimates of the resonant spectrum for the fabricated systems show good agreement with the theoretical calculations. These three systems yielded results that have led to a better understanding of the design and operation of chip scale optical sensing systems integrated with microfluidics.</p> / Dissertation
8

A fibre optic based-high resolution manometer with hydrodynamic and contact pressure specificity

Bueley, Christopher Michael 01 August 2012 (has links)
Pressure within the esophagus arises from two mechanisms: intrabolus pressure, which is a hydrodynamic phenomenon, and esophageal occlusion pressure, which is a contact phenomenon. Current esophageal manometers are sensitive to both hydrodynamic and contact pressures and cannot distinguish between the two measurements in the absence of other information. It has been shown that measurement of intrabolus pressure is a clinically relevant parameter in esophageal manometry. There is no single device available that can obtain this measurement directly. This work presents a novel fibre optic-based flexible catheter for high resolution manometry with sensing pods that can be selectively sensitized to either hydrodynamic pressure alone, or contact and hydrodynamic pressure, offering sensing schemes not possible with existing high resolution manometers. The catheter is designed to be used with a time division multiplexing interrogation technique, yielding a system capable of exceeding the 36-sensor count limit of current solid state manometers. The device consists of rigid sensing pods connected by flexible tubing with in-fiber Bragg gratings acting as sensing elements within each of the pods. Absent in each sensing pod are rigid anchor points, representing a novel departure from comparable designs and resulting in increased sensitivity and decoupling from axial loading. Device functionality is demonstrated through bench top trials. A pressure sensitivity of 1.8 pm/mmHg and axial sensitivity of 11 mmHg/N of applied load is demonstrated. Crosstalk between individual sensors is characterized and a compensation scheme is developed and validated. Temperature response is demonstrated to be linear such that its confounding can be corrected for procedurally. Sensing schemes afforded by this design may yield clinically relevant parameters not achievable by any single existing device. / Graduate
9

PORTABLE MULTIPLEXED OPTICAL DETECTION FOR POINT-OF-CARE

Shen, Li 30 September 2013 (has links)
No description available.
10

Optical Sensing of Organic Contaminants through their Immobilization and Reaction Inside Perfluorosulfonic Acid Polymer Membranes

Muthukumarasamy Ayyadurai, Subasri 18 September 2014 (has links)
No description available.

Page generated in 0.0497 seconds