• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 420
  • 92
  • 32
  • 31
  • 10
  • 5
  • 5
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 741
  • 741
  • 113
  • 112
  • 112
  • 90
  • 79
  • 79
  • 68
  • 64
  • 61
  • 57
  • 53
  • 53
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

On multiple test procedures for finding deviating parameters /

Palaszewski, Bo. January 1993 (has links)
Thesis (doctoral)--Göteborg University, 1994. / Added t.p. with thesis statement inserted. Includes bibliographical references.
122

Parametric modeling and estimation of pulse propagation on microwave integrated circuit interconnections /

Siomacco, Edward Michael. January 1990 (has links) (PDF)
Dissertation (Ph.D. in Electrical Engineering)--Naval Postgraduate School, June 1990. / Dissertation supervisor(s): Tummala., Murali. "June 1990." Description based on title page as viewed on October 16, 2009. DTIC Identifier(s): Lossy lines, Dispersive lines, Circuit interconnections, Pulse propagation, Energy transmission lines, Integrated circuits, Theses. Author(s) subject terms: Microstrip, ARMA, Parametic Modeling, Parameter Estimation. Includes bibliographical references (p. 136-140). Also available online.
123

Determining the accuracy of item parameter standard error of estimates in BILOG-MG 3

Toland, Michael D. January 2008 (has links)
Thesis (Ph.D.)--University of Nebraska-Lincoln, 2008. / Title from title screen (site viewed Nov. 25, 2008). PDF text:vii, 125 p. : ill. ; 29 Mb. UMI publication number: AAT 3317288. Includes bibliographical references. Also available in microfilm and microfiche formats.
124

A high order hidden Markov model /

Schimert, James. January 1992 (has links)
Thesis (Ph. D.)--University of Washington, 1992. / Vita. Includes bibliographical references (leaves [134]-140).
125

Numerische Methoden zur Behandlung hochdimensionaler Aufgaben der Parameteridentifizierung

Schlöder, Johannes P. January 1987 (has links)
Thesis (doctoral)--Rheinische Friedrich-Wilhelms-Universität zu Bonn. / Imprint date on cover: 1988. Bibliography: p. 146-150.
126

Estimation of catch parameters from a fishery observer program with multiple objectives /

Miller, Timothy Jason, January 2005 (has links)
Thesis (Ph. D.)--University of Washington, 2005. / Vita. Includes bibliographical references (p. 354-361).
127

Um procedimento de estimação de parâmetros de linhas de transmissão baseado na teoria de decomposição modal /

Asti, Gislaine Aparecida. January 2010 (has links)
Orientador: Sérgio Kurokawa / Banca: Afonso José do Prado / Banca: José Carlos da Costa Campos / Resumo: O objetivo deste trabalho é mostrar uma metodologia para estimar os parâmetros de linhas de transmissão. O método é baseado na teoria de decomposição modal de linhas de transmissão e é desenvolvido a partir das medições das correntes e tensões nos terminais da linha. Conforme testes realizados por Kurokawa, et al., (2006), o método de estimação de parâmetros é exato se a matriz de decomposição modal é conhecida. Desse modo, neste trabalho, o método será aplicado em uma linha de transmissão trifásica de 440 kV não transposta, em uma frequência de 60 Hz, para vários comprimentos de linhas, onde será utilizada a matriz de Clarke como sendo uma matriz de decomposição modal / Abstract: The objective of this work is to show a methodology to estimate the transmission lines parameters. The method is based the theory of modal decomposition of transmission lines and is developed from measurements of currents and voltages at the terminals of the line. According to tests realized by Kurokawa, et al. (2006), the method of parameter estimation is exact if the modal transformation matrix is known. Thus, in this work, the method will be apllied in three phase transmission line of 440 kV non transposed, in a frequency of 60 Hz, for various lengths of lines, were the matrix will be used Clarke as a modal decomposition matrix / Mestre
128

Modelagem do escoamento ao longo de evaporadores de serpentina com tubos aletados

Bueno, Sandhoerts Said [UNESP] 17 May 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-05-17Bitstream added on 2014-06-13T20:30:31Z : No. of bitstreams: 1 bueno_ss_me_ilha.pdf: 1064602 bytes, checksum: fd46f925f2d20ccedc49c80672da6280 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho, apresenta-se um modelo numérico distribuído para a simulação dos escoamentos do fluido refrigerante e do ar, no regime transiente, em evaporadores de expansão seca de serpentina com tubos aletados, comuns em sistemas de refrigeração e ar condicionado. No modelo proposto, o escoamento do fluido refrigerante no interior dos tubos é dividido em duas regiões: uma de escoamento bifásico líquido-vapor e uma de escoamento de vapor superaquecido. Considera-se a queda de pressão no interior dos tubos e a condensação do vapor d'água do ar que escoa em fluxo cruzado na parte externa dos tubos. O escoamento bifásico do fluido refrigerante é simplificado como um escoamento unidimensional, considerando o deslizamento entre as fases de líquido e de vapor. Para o escoamento do refrigerante, resolvem-se as equações de conservação da massa, da quantidade de movimento e de conservação da energia. Para o escoamento de ar, são resolvidas as equações de conservação da energia e de conservação da massa (umidade). Resolve-se, também, a equação da conservação da energia para a parede do tubo, para se obter a sua temperatura. O método de volumes finitos é utilizado na discretização das equações governantes e o método de Newton-Raphson é utilizado para a solução do sistema de equações resultante. Inicialmente, condições de regime permanente são assumidas e, posteriormente, para avaliar o comportamento transiente do evaporador, uma variação em degrau da vazão em massa de refrigerante é imposta em sua entrada. O modelo permite o cálculo da vazão de refrigerante, conhecidas as condições de operação e os parâmetros geométricos, usando-se o processo de estimativa de parâmetros, com o método de minimização de Levenberg-Marquardt. Além disso, o modelo permite a análise de algumas configurações de... . / This work presents a numerical model to simulate the unsteady refrigerant fluid flow and air flow in dry-expansion finned-tube coil evaporators, the kind widely used in air conditioning and refrigeration systems. The model considers the refrigerant flow inside the tubes divided in a region of two-phase flow and a single-phase region, where the refrigerant is in the superheated state. The refrigerant pressure drop and the moisture condensation on the air flow crossing the outside of the tubes are also taking into account. The refrigerant two-phase flow is taken as one-dimensional and the slip between the liquid and vapor phases is considered. For the refrigerant flow, mass, momentum and energy conservation equations are solved in order to evaluate the specific mass, velocity, and temperature of the refrigerant fluid, respectively. For the air flow, energy and mass (humidity) conservation equations are solved, to obtain, respectively, the temperature and absolute humidity of the air crossing the evaporator. Also, the solution of energy conservation equation for the tube wall is used to determine the wall temperature distribution. Finite Volume Method is used all over to discretize the governing equations and a Newton-Raphson Scheme is utilized for the solution of the resulting system of equations. To analyze the evaporator unsteady behavior, the steady conditions are obtained initially and later a step change in the mass flow rate is imposed at the tube inlet. Obtained results such as superheating degree along the coil and air temperature at the outlet are compared to experimental data available in the open literature. From the model the refrigerant mass flow rate can be determined, from a known operating conditions and geometry parameters, using the process of parameter estimation with the method of Levenberg-Marquardt... (Complete abstract click electronic address below).
129

Topics in image recovery and image quality assessment /Cui Lei.

Cui, Lei 16 November 2016 (has links)
Image recovery, especially image denoising and deblurring is widely studied during the last decades. Variational models can well preserve edges of images while restoring images from noise and blur. Some variational models are non-convex. For the moment, the methods for non-convex optimization are limited. This thesis finds new non-convex optimizing method called difference of convex algorithm (DCA) for solving different variational models for various kinds of noise removal problems. For imaging system, noise appeared in images can show different kinds of distribution due to the different imaging environment and imaging technique. Here we show how to apply DCA to Rician noise removal and Cauchy noise removal. The performance of our experiments demonstrates that our proposed non-convex algorithms outperform the existed ones by better PSNR and less computation time. The progress made by our new method can improve the precision of diagnostic technique by reducing Rician noise more efficiently and can improve the synthetic aperture radar imaging precision by reducing Cauchy noise within. When applying variational models to image denoising and deblurring, a significant subject is to choose the regularization parameters. Few methods have been proposed for regularization parameter selection for the moment. The numerical algorithms of existed methods for parameter selection are either complicated or implicit. In order to find a more efficient and easier way to estimate regularization parameters, we create a new image quality sharpness metric called SQ-Index which is based on the theory of Global Phase Coherence. The new metric can be used for estimating parameters for a various of variational models, but also can estimate the noise intensity based on special models. In our experiments, we show the noise estimation performance with this new metric. Moreover, extensive experiments are made for dealing with image denoising and deblurring under different kinds of noise and blur. The numerical results show the robust performance of image restoration by applying our metric to parameter selection for different variational models.
130

Modelagem do escoamento ao longo de evaporadores de serpentina com tubos aletados /

Bueno, Sandhoerts Said. January 2004 (has links)
Orientador: André Luiz Seixlack / Banca: Marco Antonio Soares de Paiva / Banca: Sérgio Said Mansur / Resumo: Neste trabalho, apresenta-se um modelo numérico distribuído para a simulação dos escoamentos do fluido refrigerante e do ar, no regime transiente, em evaporadores de expansão seca de serpentina com tubos aletados, comuns em sistemas de refrigeração e ar condicionado. No modelo proposto, o escoamento do fluido refrigerante no interior dos tubos é dividido em duas regiões: uma de escoamento bifásico líquido-vapor e uma de escoamento de vapor superaquecido. Considera-se a queda de pressão no interior dos tubos e a condensação do vapor d'água do ar que escoa em fluxo cruzado na parte externa dos tubos. O escoamento bifásico do fluido refrigerante é simplificado como um escoamento unidimensional, considerando o deslizamento entre as fases de líquido e de vapor. Para o escoamento do refrigerante, resolvem-se as equações de conservação da massa, da quantidade de movimento e de conservação da energia. Para o escoamento de ar, são resolvidas as equações de conservação da energia e de conservação da massa (umidade). Resolve-se, também, a equação da conservação da energia para a parede do tubo, para se obter a sua temperatura. O método de volumes finitos é utilizado na discretização das equações governantes e o método de Newton-Raphson é utilizado para a solução do sistema de equações resultante. Inicialmente, condições de regime permanente são assumidas e, posteriormente, para avaliar o comportamento transiente do evaporador, uma variação em degrau da vazão em massa de refrigerante é imposta em sua entrada. O modelo permite o cálculo da vazão de refrigerante, conhecidas as condições de operação e os parâmetros geométricos, usando-se o processo de estimativa de parâmetros, com o método de minimização de Levenberg-Marquardt. Além disso, o modelo permite a análise de algumas configurações de... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: This work presents a numerical model to simulate the unsteady refrigerant fluid flow and air flow in dry-expansion finned-tube coil evaporators, the kind widely used in air conditioning and refrigeration systems. The model considers the refrigerant flow inside the tubes divided in a region of two-phase flow and a single-phase region, where the refrigerant is in the superheated state. The refrigerant pressure drop and the moisture condensation on the air flow crossing the outside of the tubes are also taking into account. The refrigerant two-phase flow is taken as one-dimensional and the slip between the liquid and vapor phases is considered. For the refrigerant flow, mass, momentum and energy conservation equations are solved in order to evaluate the specific mass, velocity, and temperature of the refrigerant fluid, respectively. For the air flow, energy and mass (humidity) conservation equations are solved, to obtain, respectively, the temperature and absolute humidity of the air crossing the evaporator. Also, the solution of energy conservation equation for the tube wall is used to determine the wall temperature distribution. Finite Volume Method is used all over to discretize the governing equations and a Newton-Raphson Scheme is utilized for the solution of the resulting system of equations. To analyze the evaporator unsteady behavior, the steady conditions are obtained initially and later a step change in the mass flow rate is imposed at the tube inlet. Obtained results such as superheating degree along the coil and air temperature at the outlet are compared to experimental data available in the open literature. From the model the refrigerant mass flow rate can be determined, from a known operating conditions and geometry parameters, using the process of parameter estimation with the method of Levenberg-Marquardt... (Complete abstract click electronic address below). / Mestre

Page generated in 0.0581 seconds