• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 10
  • 1
  • Tagged with
  • 24
  • 24
  • 6
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The feasibility of utilizing grey water in Hong Kong buildings /

Leung, Suet-fai. January 2002 (has links)
Thesis (M. Sc.)--University of Hong Kong, 2002. / Includes bibliographical references.
2

Powdered activated carbon for nitrogen removal in wastewater treatment

Berndt, Craig Lester, January 1976 (has links)
Thesis--Wisconsin. / Includes bibliographical references (leaves 323-330).
3

An institutional and economic assessment of water reuse in the Tucson Basin

Lieuwen, Andrew L. January 1989 (has links) (PDF)
Thesis (Ph. D. - Hydrology and Water Resources)--University of Arizona, 1989. / Includes bibliographical references (leaves 245-252).
4

Action of autochthonous bacteria on the decay of enteric viruses in groundwater /

Wall, Katrina. January 1900 (has links)
Thesis (Ph.D.)--Murdoch University, 2006. / Thesis submitted to the Division of Science and Engineering. Includes bibliographical references (leaves 148-163)
5

Microbial reduction of sulfur dioxide in a continuous culture of Desulfovibrio Desulfuricans /

Selvaraj, Punjai T. January 1994 (has links)
Thesis (Ph.D.)--University of Tulsa, 1994. / Includes bibliographical references (leaves 141-143).
6

Removal of natural steroid hormones from wastewater using membrane contractor processes

Cartinella, Joshua L. January 2008 (has links)
Thesis (M.S.)--University of Nevada, Reno, 2006. / "August, 2006." Includes bibliographical references (leaves 67-70). Online version available on the World Wide Web.
7

Performance of water recycling technologies

Al-rifai, Jawad Hilmi. January 2008 (has links)
Thesis (Ph.D.)--University of Wollongong, 2008. / Typescript. Includes bibliographical references.
8

Small-scale constructed wetland for onsite light grey water treatment and recycling

Kadewa, Wilfred William January 2010 (has links)
This study focused on the investigation of the impact of household cleaning and personal care products on the quality of grey water and the assessment and optimisation of grey water treatment by a novel constructed wetland design. The prototype wetland design which comprised three-stage cascading beds (0.27 m 2 by 0.20 m deep) with sand media, (d10: 1.0 mm and d90: 4.0 mm) was tested for treatment performance to meet non-potable reuse standards in three versions, unplanted open beds, unplanted covered beds, and planted beds (comprising mixtures of Iris pseudacorus, Iris chrysographes, Carex elata Aurea and Mentha aquatica). The prototypes were benchmarked against a standard single-pass wetland (6 m 2 by 0.7 m) planted with Phragmites australis. Performance was measured in terms of removal of conventional water quality determinant parameters, as well as Total coliforms and E coli, and surfactants. Microbial dynamics were also monitored during the study by looking at variations in microbial compositions with time for the different wetlands. All the wetland versions effectively removed more than 98 % turbidity and organics meeting the most stringent reuse wastewater reuse standards of < 2.0 NTU and < 10 mg BOD5/L respectively. The influent grey water had low BOD:COD ratio ranging from 0.27 – 0.45, which is indicative of low biodegradability. The comparison of the cascade wetland performances showed the following: open beds > planted = covered, with the open beds version meeting reuse standards virtually throughout the monitoring period, despite recurrence of schmutsdecke in the top bed. All wetland technologies supported viable populations of microorganisms. Only phospholipid fatty acids (PLFAs) of lower carbon chain length (< C20) had concentrations greater than 1 mol %, in all the wetlands beds, confirming that the majority of the PLFAs in the media were from contribution of microbial organisms and not plant organic matter. Characterisation of microbial organisms was carried out to understand the constructed wetlands functioning and thus the treatment processes. The household products showed nutrient deficiency signifying low treatability. Product branding did not show correlation with any water quality parameters. In terms of toxicity, laundry and cleaning products were more inhibiting to soil microorganisms than were personal care products.
9

Innovative Treatment Technologies for Reclaimed Water

Bandy, Jeff January 2009 (has links)
<p>In order to meet disinfection guidelines, wastewater utilities must achieve a high level of treatment before discharging treated water for irrigation or industrial use. However, public pressure to reduce disinfection by-products and pharmaceutically-active compounds, recently-promulgated regulations on chlorine-resistant microorganisms such as Cryptosporidium parvum, and growth in population and water demand have driven an interest in alternatives to chlorination. The WateReuse Foundation has funded WRF 02-009 (Innovative Treatment Technologies for Reclaimed Water), which is a survey of current and emerging reuse water treatment technologies. The goal of the project is to evaluate treatment technologies can provide adequate recycled water effluent without the cost of reverse osmosis (RO) or the disinfection by-products (DBPs) formed during chlorination.</p><p>The inactivation of indigenous microorganisms (total and fecal coliform bacteria, and total aerobic spores) and spiked surrogate, respiratory, and enteric viruses (MS-2 bacteriophage, adenovirus type 4, reovirus type 3, and coxsackievirus type B5) and chemical degradation by wastewater treatment technologies was evaluated on the bench-scale. These include: low- and medium-pressure UV, LPUV/H<sub>2</sub>O<sub>2</sub>, ozonation, O<sub>3</sub>/H<sub>2</sub>O<sub>2</sub>, peracetic acid (PAA), LPUV/PAA, chlorination, chloramination, and ultrafiltration. The applicability of the candidate disinfection methods, especially emerging and comparatively untested methods such as PAA and advanced oxidation processes (AOPs), was studied through comparison of their performance and the important water matrix parameters (e.g., alkalinity, BOD, TSS, etc.).</p><p>Of the chemical disinfectants, molecular ozone and free chlorine were the most effective, with substantial coliform and virus kill at low doses. Combined chlorine in the form of monochloramine had a reduced disinfectant capacity than free chlorine, and peracetic acid (PAA) performed equally as well as free chlorine with respect to coliform bacteria in some instances but had little to no impact on spiked MS2 bacteriophage. None of the aforementioned disinfectants had an appreciable impact on indigenous aerobic spore-forming bacteria due to their physiology. UV and O<sub>3</sub> rapidly killed human enteric and respiratory viruses, but a consistent benefit by AOPs over their base technologies was not observed for any of their base technologies.</p><p>Low and medium-pressure UV inactivated free-floating indigenous coliform bacteria almost immediately, while slower inactivation rates at higher UV fluences illustrated the "tailing" behavior observed when bacteria are embedded in or shielded by particulate matter. Log-linear inactivation of spiked viruses and indigenous aerobic spores by UV was consistent across the utility waters. The UV-based advanced oxidation processes (UV/H<sub>2</sub>O<sub>2</sub> and UV/PAA) destroyed spiked organic compounds at much higher rates than direct UV photolysis, while O<sub>3</sub>, with or without H<sub>2</sub>O<sub>2</sub> , oxidized spiked compounds and reduced estrogenicity (EEQ) at low doses. Recalcitrant chlorinated hydrocarbons such as TCEP were only moderately removed by the tested AOPs, but low doses of O<sub>3</sub> (3 ppm residual O<sub>3</sub>) reduced estrogenic activity by 99%. Like other disinfection processes, AOP performance is dependant on pretreatment, especially concerning particulates.</p> / Dissertation
10

Development and trial of a low-cost aerobic greywater treatment system

Okalebo, Susan. January 2004 (has links)
Thesis (M.Eng.) -- University of Western Sydney, 2004. / A thesis submitted in fulfilment of the requirements for the degree of Master of Engineering at the University of Western Sydney. Includes bibliography.

Page generated in 0.0437 seconds