[en] USE OF PERACETIC ACID AS BIOCIDE IN COOLING TOWER WATER TREATMENT / [pt] USO DE ÁCIDO PERACÉTICO COMO BIOCIDA EM TRATAMENTO DE ÁGUA DE TORRE DE RESFRIAMENTO

ANA CRISTINA VICENTE 18 October 2019 (has links)
[pt] O crescimento microbiológico em águas de sistemas de resfriamento pode resultar na formação de biofilme, o qual pode causar problemas de biocorrosão, perdas de carga em tubulações, redução de taxa de transferência de calor e obstrução de fluxo. Os principais e tradicionais biocidas utilizados no controle microbiológico de águas de resfriamento são os compostos à base de cloro. Entretanto, nos últimos anos o ácido peracético tornou-se uma alternava aos compostos clorados, uma vez que este biocida deixa como resíduo apenas o acetato o qual é biodegradável e não forma subprodutos organoclorados. Este trabalho analisou a aplicação do ácido peracético comparando-o com o hipoclorito de sódio no controle microbiológico e na corrosividade de materiais, empregando uma árvore de teste em escala de laboratório. Foi investigada a taxa de corrosão dos materiais metálicos de aço carbono, cobre e aço inoxidável, além da efetividade na redução da contagem bacteriana. Os experimentos foram realizados em condições de fluxo turbulento, pH 8 e temperatura de 32 C empregando uma água de estudo real, carregada de matéria orgânica (DQO = 350 mg/L). As concentrações usadas de ácido peracético foram 0,75; 1,0 e 3,0 mg/L e de hipoclorito de sódio foram 1,0 e 3,0 mg/L. O ácido peracético na concentração de 3,0 mg/L reduziu a carga bacteriana de 1,5x10 (elevado a 5) UFC/mL para 5,24x10 (elevado a 3) UFC/mL. Comparado ao hipoclorito de sódio, o ácido peracético foi menos corrosivo para o aço carbono em todas as concentrações. Na concentração de 1,0 mg/L a taxa de corrosão do cobre em ácido peracético foi menor do que na solução de hipoclorito de sódio. Já na concentração de 3,0 mg/L ocorreu o inverso. Não foi observada corrosão significativa no aço inoxidável para os biocidas estudados. / [en] Microbiological growth in cooling systems water may result in biofilm formation, which can cause problems of bio-corrosion, pressure drop in the pipes, reduction of heat transfer rate and flow obstruction. The main and traditional biocides applied in microbiological control of cooling waters are the chlorine based compounds. However, in recent years, peracetic acid has become an alternative to chlorinated compounds, since this biocide leaves as residue only the acetate, which is biodegradable and does not form chlorinated organic byproducts. This work analyzed the application of peracetic acid comparing to sodium hypochlorite in the microbiological control and material corrosivity using a laboratory scale test tree. The corrosion rate of carbon steel, copper and stainless steel alloys in addition to the effectiveness in reducing the bacterial count. The experiments were carried out under conditions of turbulent flow, pH 8 and temperature of 32 C using a real industrial test water loaded with organics (COD = 350 mg/L). Peracetic acid concentrations used were 0.75, 1.0 and 3.0 mg/L and sodium hypochlorite were 1.0 and 3.0 mg/L. Peracetic acid at the concentration of 3.0 mg/L decreased the bacterial load from 1.5x10 (raised to 5) UFC/mL to 5.24x10 (raised to 3) UFC/mL. Peracetic acid compared to sodium hypochlorite was less corrosive to carbon steel at all concentrations. At the concentration of 1.0 mg/L the corrosion rate of copper in peracetic acid was lower than in sodium hypochlorite solution. At the concentration of 3.0 mg/L, the reverse occurred. No significant corrosion was observed in stainless steel for the biocides studied.
2

[en] COOLING WATER BIOCIDAL TREATMENT USING PERACETIC ACID / [pt] TRATAMENTO BIOCIDA DE ÁGUAS DE RESFRIAMENTO COM ÁCIDO PERACÉTICO

RENATA TOMOE MITSUYA 17 January 2019 (has links)
[pt] O objetivo deste estudo foi avaliar o efeito biocida do ácido peracético (APA) em águas de sistemas de resfriamento, de forma a buscar alternativas ao uso do cloro, que é corrosivo e reage com a matéria orgânica natural ou sintética presentes na água, formando subprodutos tóxicos. Para atingir este objetivo, experimentos utilizando amostras de água retiradas da bacia de uma torre de resfriamento de uma indústria química foram realizados. Ensaios foram executados utilizando-se uma solução comercial de APA, mantendo-se concentrações do biocida em 1,0 mgL-1 e 2,0 mgL-1 em pH 8,0 e 8,8. Cada condição de estudo foi monitorada ao longo de 5 dias, e contagens de bactérias heterotróficas mesófilas totais foram realizadas tanto antes da aplicação do biocida como em diferentes tempos de contato do biocida com a microbiota natural da água. Os tempos de contato monitorados foram de 5 min, além de 1, 2 e 4 h por dia considerando a aplicação do biocida em períodos totais de 4 h por dia. Com esta metodologia foi possível concluir que as duas dosagens aplicadas foram eficientes no combate aos microrganismos presentes naturalmente nas amostras de água, nos dois valores de pH estudados. A partir de uma carga microbiana natural da água de 106 a 107 UFC/mL, após o tratamento houve uma redução para contagens de no máximo de 104 UFC/mL em todos os experimentos, limite máximo esse adotado pelas indústrias para carga microbiana em águas de sistemas de resfriamento, entretanto, houve maior eficiência, cerca de 10 vezes maior, quando 2,0 mgL-1 de APA foi aplicado. Além disso, em pH 8,0 a ação do biocida também foi superior em 10 vezes em detrimento ao pH 8,8 para a mesma concentração de APA. / [en] The purpose of this study was to evaluate the biocidal effect of peracetic acid (PAA) in cooling water, in order to find alternatives to the use of chlorine, which is corrosive and reacts with natural and synthetic organic matter present in water, forming toxic byproducts. To achieve this goal, experiments using water samples taken from a basin of a chemical industry cooling tower were conducted. Experiments were performed using a commercial PAA solution, with concentrations of 1,0 mgL-1 and 2,0 mgL-1 and pH 8,0 and 8,8. Each study condition was monitored for 5 days and total mesophilic heterotrophic bacteria counts were made without biocide and after different contact times of the biocide and microorganisms present in water. The contact times were 5 min, and 1, 2 and 4 h per day, considering the application of the biocide in total periods of 4 h per day. This methodology has allowed concluding that two dosages applied were efficient in controlling microorganisms at the two pH values. From a water natural microbial count of 106 to 107 UFC/mL, after treatment there was a reduction to maximum counts to 104 UFC/mL in all experiments, that being the upper limit adopted by industries for microorganisms in cooling water systems. However, the results were 10 times more efficient when 2,0 mgL-1 of PAA were applied. In addition, at pH 8,0 the biocidal action was 10 times higher in comparison to pH 8,8 for the same PAA concentration.