• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] TRANSIENT HEAT TRANSFER MODELING OF THERMALLY INSULATED OIL OR GAS PIPELINES / [pt] MODELAGEM TRANSIENTE DA TRANSFERÊNCIA DE CALOR EM DUTOS DE PETRÓLEO OU GÁS, TERMICAMENTE ISOLADOS

JHOANY JHORDANN BARRERA ESCOBEDO 07 February 2006 (has links)
[pt] Linhas submarinas são utilizadas na produção e transporte de petróleo e seus derivados. Em ambas as situações, o controle da transferência de calor do fluido para o ambiente externo pode ser um fator determinante para o escoamento. No caso de produção em águas profundas, o fluido aquecido perde calor para a água do mar gelada. A perda de calor é controlada através do isolamento térmico, o qual é projetado para operações de escoamento em regime permanente. Durante eventuais paradas de operação, o fluido estagnado no interior da tubulação ao perder calor para o ambiente frio, pode atingir níveis críticos de temperatura, acarretando graves problemas, tais como formação de hidratos ou deposição de parafina nas paredes da tubulação, o que pode levar ao bloqueio da linha e interrupção de produção. No transporte de produtos, o reinício de bombeio de fluidos muitos viscosos também é um problema crítico, devido ao aumento significativo da viscosidade com a redução da temperatura. O presente trabalho apresenta uma análise da influência da capacidade térmica da parede do tubo e das camadas de revestimento no transiente térmico de linhas com muito isolamento. A perda de calor da linha para o ambiente é determinada resolvendo-se a equação transiente de condução de calor para as camadas de revestimento da tubulação, utilizando um modelo uni-dimensional na direção radial. O método de volumes finitos é empregado para resolver o escoamento transiente no interior da tubulação acoplado com o transiente térmico na parede da tubulação, a partir do instante em que uma válvula é fechada na extremidade da tubulação interrompendo o fluxo. Comparações com as previsões de softwares comerciais foram realizadas e suas limitações são discutidas. Resultados obtidos das simulações para o escoamento tanto de líquidos quanto de gases, considerando e desprezando a capacidade térmica, mostram que o efeito da mesma é relevante na determinação do tempo de resfriamento da linha e do fluido em seu interior. / [en] Subsea pipelines are employed not only for production but also for transportation. In both situations, warm oil loses heat to the cold sea water. The heat loss to the ambient is controlled by means of thermal insulation, which is designed for steady state operations. During shutdowns, the stagnant fluid in the pipeline loses heat to the cold surrounding, eventually reaching some critical temperature. As a result, several problems can occur, such as formation of hydrates or deposition of high molecular weight paraffins on the inner wall of the subsea line, which can lead to flow line blockage and production shutdown. Restart of very viscous fluid after shutdown is also critical, since viscosity increases significantly with the reduction of the temperature. This work presents an analysis of the influence of the pipe wall thermal capacitance on the transient behavior of heavily insulated lines. The heat loss from the pipeline is determined, by solving the transient heat conduction equation for the pipewall layers, utilizing a simple one-dimensional model in the radial direction. The finite volume method is employed to solve the transient flow inside the pipeline, from the time instant that a valve at the end point of the line is closed, coupled with the pipe wall thermal transient. Comparisons with the prediction of commercial softwares were performed and their limitations are addressed. Numerical results obtained for flows of both liquid and gases, considering and neglecting the thermal capacitance, revealed that accounting for the thermal capacity of the wall is relevant to the determination of cooldown times
2

[en] STUDY OF THE SYSTEM AL2O3-MNO / [pt] ESTUDO DO SISTEMA AL2O3-MNO: PROPRIEDADES TERMODINÂMICAS DO ÓXIDO AL2MNO4

ROGERIO NAVARRO CORREIA DE SIQUEIRA 16 January 2018 (has links)
[pt] No presente trabalho foram realizadas medidas de capacidade térmica à pressão constante do espinélio Al2MnO4 na faixa entre 2 e 873 K. No intervalo entre 2 e 300 K empregou-se um calorímetro de relaxação térmica. Os dados evidenciaram a presença de uma anomalia em torno de 33 K, cuja componente magnética pôde ser constatada mediante medidas de capacidade calorífica com campo magnético constante, bem como também medidas de magnetização específica como função da temperatura. A contribuição entrópica associada à mencionada anomalia foi considerada no cálculo da entropia molar a 298.15 K do óxido em questão (116.05 mais ou menos 5.2 J/mol.K), valor este consistente com valores da literatura para outros espinélios. Na faixa entre 323 e 873 K empregou-se um calorímetro diferencial de varredura. Os dados foram ajustados quantitativamente com o modelo de Berman e Brown, incluindo-se no ajuste o valor de capacidade térmica a 298.15 K, obtido via calorimetria de relaxação térmica. Empregando-se o valor de entropia molar determinado no presente trabalho, os parâmetros do modelo de Berman e Brown estimados com os dados em temperaturas elevadas, e uma estimativa disponível na literatura para a entalpia de formação do óxido Al2MnO4, construiu-se um modelo para a dependência térmica da energia de Gibbs do referido composto válido na faixa entre 298.15 e 2114 K. O modelo foi testado com sucesso no acesso termodinâmico das propriedades do sistema Al2O3-MnO. / [en] In the present work the constant pressure molar heat capacity of the spinel Al2MnO4 was measured between 2 K and 873 K. In the interval between 2 K and 300 K a relaxation calorimeter was employed. The data indicated the presence of a thermal anomaly around 33 K, whose magnetic component could be evidenced through measurements of the heat capacity with a constant applied magnetic field, and also through specific magnetization data as a function of temperature. The entropic contribution of the thermal anomaly was considered in the calculation of the molar entropy of the oxide at 298.15 K (116.05 more or less 5.2 J/mol.K), and the calculated value has proven to be consistent with values published earlier for other spinel compounds. In the interval between 323 and 873 K a differential scanning calorimeter was employed. The data were quantitatively modeled with the function proposed by Berman and Brown, including the heat capacity value obtained at 298.15 K accessed through the relaxation calorimeter route. By using the molar entropy at 298.15 K, the values of the parameter estimated for the Berman and Brown model with the heat capacity data at elevated temperatures, and an estimative for the heat of formation of the spinel Al2MnO4 extracted from the literature, it was possible to construct a model for the thermal dependence of the Gibbs energy of this compound valid between 298.15 K and 2114 K. The model was successfully tested in the thermodynamic assessment of the properties of the system Al2O3-MnO.

Page generated in 0.0304 seconds