[en] MEASUREMENT OF POLARIZATION DEPENDENT LOSS USING FREQUENCY MIXING IN PHOTODIODES / [pt] MEDIÇÃO DE PERDAS DEPENDENTES DA POLARIZAÇÃO UTILIZANDO MISTURA DE FREQUÊNCIAS EM FOTODIODOS

CAMILA SEABRA NOBRE 05 February 2016 (has links)
[pt] Este trabalho apresenta um método teórico e experimental para medir Perda Dependente de Polarização (PDL) em sistemas ópticos. Este método basea-se na forma como duas componentes de polarização ortogonais da luz moduladas em amplitude por duas frequências distintas são acopladas no detector após a transmissão pelo dispositivo sob caracterização. No presente trabalho é realizado um estudo acerca das propriedades da luz e das técnicas tradicionais utlizadas para medir PDL. Antes da caracterização das medidas de PDL, foi realizado o alinhamento do dispositivo de teste (DUT), ou seja, do sistema que vai emular a PDL, a fim de garantir que o mesmo estivesse com as perdas ópticas minimizadas. Em seguida, conectou-se o DUT à configuração montada no laboratório, sendo realizado os ajustes de polarização e supressão das portadoras ópticas. Neste método é possível calcular o valor da PDL e da na orientação na Esfera de Poincaré. / [en] This work presents a theoretic and experimental method for Polarization Dependent Loss (PDL) measurement in optical systems. This method is based on how two orthogonal polarization components both modulated in amplitude by two different frequency are coupled in the detector. In this present work a study is performed about light properties and traditional techniques used to peform PDL measurement. Before the characterization of PDL measures the alignment of the device under test (DUT) was performed to make sure that optical losses were minimized in the system which will emulate the PDL. Then, the DUT was connected to the experimental setup to optical carriers suppression and polarization alignment. In this method is possible to calculate the PDL value and its orientation on the Poincaré sphere.

Page generated in 0.0389 seconds