• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] DEVELOPMENT OF A PHOTOCHEMICAL DERIVATIZATION PROCEDURE FOR TWO SYNTHETIC GLUCOCORTICOIDS (PREDNISOLONE AND TRIAMCINOLONE ACETONIDE) AIMING THE SPECTROFLUORIMETRIC ANALYSIS OF PHARMACEUTICAL FORMULATIONS / [pt] DESENVOLVIMENTO DE PROCEDIMENTO DE DERIVATIZAÇÃO FOTOQUÍMICA PARA DOIS GLICOCORTICÓIDES SINTÉTICOS (PREDNISOLONA E TRIANCINOLONA ACETONIDO) VISANDO À ESPECTROFLUORIMÉTRICA DE FORMULAÇÕES FARMACÊUTICAS

ANETE LOPES COELHO 08 April 2005 (has links)
[pt] Os glicocorticóides sintéticos tais como a triancinolona acetonido e a prednisolona não possuem fluorescência natural e nem são induzidos a fluorescer por meio do procedimento padrão para glicocorticóides naturais, que consiste no tratamento com ácido sulfúrico concentrado. No presente trabalho, um procedimento de derivação fotoquímica para triancinolona acetonido e prednisolona foi desenvolvido e cuidadosamente otimizado com o intuito de se obter derivados fluorescentes estáveis que permitiram elaborar um método espectrofluorimétrico para determinação dos mesmos em formulações farmacêuticas. Este procedimento consistiu na exposição à radiação ultravioleta (300 nm) de soluções ácidas dos glicocorticóides sintéticos em reator fotoquímico. Parâmetros experimentais, tais como tipo e concentração do ácido, temperatura e tempo de aquecimento, sistema de solventes e tempo de exposição ao UV se mostraram críticos e por isso foram cuidadosamente estudados. As características do reator também se mostraram importantes para o sucesso do procedimento. A intensidade da fluorescência (excitação em 240 nm e emissão em 350 nm) e a estabilidade dos fotoprodutos se mostraram apropriados para permitir o desenvolvimento de um método espectrofluorimétrico. Parâmetros instrumentais importantes, tais como banda espectral de passagem e a velocidade de varredura foram otimizados, visando à obtenção da melhor razão sinal do analito/sinal do branco e da melhor resolução espectral. Parâmetros analíticos de mérito, obtidos a partir das curvas analíticas, revelaram limites de detecção de 5 e 6 ng mL-1 para triancinolona acetonido e prednisolona, respectivamente; e limites de quantificação de 17 ng mL-1 para a triancinolona acetonido e 19 ng mL-1 para a prednisolona. As faixas lineares dinâmicas, nos dois casos, se estenderam por três ordens de grandeza com coeficientes de linearidade (r2) de 0,99. Este método espectrofluorimétrico foi testado em formulações farmacêuticas, obtendo-se os melhores resultados para os comprimidos e soluções injetáveis. Estudos para avaliar o efeito de dois potenciais interferentes (polimixina B e benzocaína) também foram realizados. Resultados de recuperação foram avaliados tomando como referência os valores indicados na bula do medicamento e também valores obtidos com o procedimento de referência (HPLC com detecção fotométrica UVvis) utilizado no Jockey Club Brasileiro, obtendo resultados entre 97 ± 14 e 104 ± 6 %. / [en] The synthetic glucocorticoid such as triamcinolone acetonide and prednisolone neither present natural fluorescence nor fluorescence can be induced by means of the standard procedure used for natural glucocorticoids which consists on a treatment with concentrated sulfuric acid. In the present work, a photochemical derivatization procedure for these two synthetic glucocorticoids was developed and carefully optimized aiming the obtantion of fluorescent derivatives stable enough to allow the development of a spectrofluorimetric method for determination of these analytes in pharmaceutical formulations. The photochemical derivatization procedure consisted on the exposure of acidic solutions of these synthetic glucocorticoids to the ultraviolet radiation (300 nm) in a photochemical reactor. Experimental parameters such as type and concentration of the acid, temperature and heating time, solvent system and UV exposition time have shown to be critical and therefore they were carefully studied. The design of the photochemical reactor) has also shown to be relevant for the success of the procedure. The intensity of the fluorescence (with maximum excitation and emission wavelenghts at 240 nm and 350 nm respectively) and the stability of these photoproducts, have shown to be appropriated for the development of a spectrofluorimetric method. Important instrumental parameters such as spectral bandpass and scan velocity have been optimized aiming the achievement of best signal-to-blank ratio and spectral resolution. Analytical parameters of merit, obtained from the analytical curve, have indicated limits of detention of 5 and 6 ng mL-1 for triamcinolone acetonide and prednisolone, respectively, and limits of quantification of 17 ng mL-1 for triamcinolone acetonide and 18 ng mL-1 for prednisolone. The linear dynamic range for both analytes extended over three orders of magnitude with linear coefficients (r2) of 0,99. The spectrofluorimetric method was tested by the analysis of pharmaceutical formulations, with best performance for tablets and injectable solutions. A study to evaluate the effect of two potential interferents (polimixine B and benzocaine) has also been made. Recovery results were evaluated using both, the reference values indicated in the medicine instructions and concentration values obtained using the reference procedure (HPLC with UV-visible photometric detection) used in the Brazilian Jockey Club. Satisfactory recovery results were achieved (between 97 ± 14 and 104 ± 6 %).

Page generated in 0.035 seconds