• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] MODELO DE TOLERÂNCIA ÀS TRINCAS CURTAS APLICADO A ANÁLISE ESTRUTURAL DE FRAGILIZAÇÃO PELO HIDROGÊNIO EM SISTEMAS DE SALMOURA CONTENDO H2S E HIDROGÊNIO GASOSO EM ALTA PRESSÃO / [en] TOLERANCE TO SHORT CRACK MODELING APPLIED TO THE STRUCTURAL ANALYSIS OF HYDROGEN EMBRITTLEMENT UNDER H2S BRINE SYSTEMS AND HIGH-PRESSURE GASEOUS HYDROGEN

RODRIGO VIEIRA LANDIM 10 October 2024 (has links)
[pt] O desenvolvimento de novas tecnologias com Hidrogênio como fonte de energia ressalta um antigo desafio nos meios de transporte e armazenamento desse, visto que todos materiais estruturais têm susceptibilidade a fragilização pelo hidrogênio. A forma usual de resolver esse problema é o uso de materiais nobres e mais resistentes a fragilização pelo hidrogênio. Uma alternativa para o dimensionamento mecânico em condições de fragilização pelo hidrogênio vem da modelagem de trincas curtas através da mecânica da fratura linear elástica ou Elasto-Plástica. Esses modelos consideram dois parâmetros do material, o Limite de Resistência ao Trincamento Assistido pelo Ambiente e o Limiar de Propagação de Trincas no meio. Nesse trabalho o modelo proposto é validado experimentalmente em condições de Corrosão sob Tensão Induzida por Sulfetos (aço de alta resistência e baixa liga e o aço inoxidável super martensítico UNS S41426 expostos ao sulfeto de hidrogênio), bem como o aço 17-4PH em 200bar(g) de H2. O método de teste T-WOL recomendado no código ASME BPVC para a obtenção da tenacidade à fratura sob alta pressão de H2 é avaliada para materiais com alta tenacidade, a qual não apresentou bons resultados. Como alternativa, uma metodologia modificada a partir da norma ASTM E1820 para obter a curva J-R em H2 a alta pressão é testada, obtendo o limiar de propagação de trincas em condições Elasto-Plásticas. Durante as atividades, uma célula de carga utilizada no interior da autoclave de teste falhou quando exposta a 200bar(g) de H2. Foi realizada análise de falha e redimensionamento, conforme o modelo de trincas curtas proposto, para que células semelhantes pudessem ser utilizadas nos testes subsequentes / [en] The development of new technologies with hydrogen as an energy source underscores a longstanding challenge in its transportation and storage, since all structural materials are susceptible to hydrogen embrittlement. The usual approach to solve this problem is to use nobler materials more resistant to hydrogen embrittlement. An alternative approach to mechanical design under hydrogen embrittlement conditions involves the modeling of the behavior of short cracks through linear elastic or elastoplastic fracture mechanics. These models consider two key material parameters: the Environmental Assisted Cracking Resistance Limit and the Crack Propagation Threshold in the environment. In this study, the proposed model is validated by suitable tests under sulfide stress corrosion cracking - High Strength and Low Alloy steel and a supermartensitic stainless steel UNS S41426 exposed to hydrogen sulfide, and in a 17-4PH steel exposed to high-pressure gaseous hydrogen, at 200 bar(g) of H2. A T-WOL test methodology recommended in ASME BPVC code for measuring the fracture toughness at high pressure of H2 for materials with high toughness is evaluated, and it yields unsatisfactory results. As an alternative, a modified ASTM E1820 test method is proposed to obtain the J-R curve under high-pressure H2, obtaining the crack propagation threshold at elastoplastic conditions. During these activities, a load cell used within the test autoclave failed when exposed to 200 bar(g) of H2. Failure analysis and a new design were conducted according the short crack tolerance model, to allow the use of similar load cells in the following tests.

Page generated in 0.0349 seconds