• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[pt] AVALIAÇÃO METROLÓGICA DA MEDIÇÃO DO MÓDULO DE ELASTICIDADE DE MATERIAIS POLIMÉRICOS PELA MICROSCOPIA DE FORÇA ATÔMICA, NO MODO PEAK FORCE TAPPING / [en] METROLOGICAL EVALUATION OF THE MEASUREMENT OF THE MODULUS OF ELASTICITY OF POLYMERIC MATERIALS BY ATOMIC FORCE MICROSCOPY, IN THE PEAK FORCE TAPPING MODE

JUAN DAVID CAICEDO VASQUEZ 01 September 2020 (has links)
[pt] Ao longo das últimas décadas, mais intensamente, a microscopia de força atômica (AFM) tem sido utilizada em atividades de pesquisa e desenvolvimento, notadamente para a caracterização de materiais. Não obstante os avanços e sofisticações da técnica, a determinação do módulo de elasticidade de materiais poliméricos continua sendo um desafio dada a complexidade de caracterização de materiais complexos, comumente gerando expressivo espalhamento nos resultados de medição. Esta pesquisa de mestrado apresenta mapeamentos da morfologia e medições do módulo de elasticidade de celulose comercial (fibras de bambu e de eucalipto) e lignocelulósico, referenciados a materiais poliméricos sintéticos já caracterizados (considerados como padrão). A microscopia de força atômica (AFM), no modo peak force tapping, alternativamente fundamentada no modelo Derajaguin-Muller-Toporo, DMT (que é o modelo incorporado no software da Bruker, fabricante do equipamento AFM) e no modelo JohnsonKendall-Robert, JKR (proposto neste trabalho, fazendo-se uso de um algoritmo Matlab), foi utilizada como técnica de medição do módulo de elasticidade dos materiais investigados. A partir dos ensaios realizados, foi possível avaliar o método de medição com base em critérios metrológicos e determinar o modelo de cálculo mais apropriado para a caracterização dos materiais investigados. Para os materiais padrão utilizados como referência, e cujos valores do módulo de elasticidade são informados pelos respectivos fornecedores (E igual 2,7 mais ou menos 0,1 GPa, para o poliestireno e E igual 1,8 GPa, para a poliamida), o modelo JKR mostrou-se mais adequado para fundamentar o cálculo do módulo de elasticidade. Enquanto o modelo JKR reproduziu o valor do fabricante com 6,3 porcento, para o caso do poliestireno (E igual 2,540754 mais ou menos 0,056 GPa) e com 12,5 porcento, para o caso da poliamida (E igual 1,680050 mais ou menos 0,041 GPa), o modelo DMT produziu resultados com desvios superiores a 50 porcento do valor de referência considerado como padrão. Fundamentado nesses mesmos modelos DMT e JKR, o trabalho avaliou o módulo de elasticidade de outros materiais, mais especificamente: (i) filme de celulose extraída do eucalipto; (ii) filme de celulose microfobrilada comercial; (iii) filme de celulose microfibrilada, depositada no laboratório pela técnica de ultrassom e (iv) amostras de bambu (Dendrocalamus Giganteus), extraídas da seção externa e interna do colmo d o bambu. Os resultados são discutidos em conformidade ao rigor metrológico dos componentes estocásticos e determinísticos da incerteza associada às medições realizadas, confirmando que a microscopia de força atômica (AFM), no modo peak force tapping se apresenta como técnica promissora para ser utilizada como ferramenta metrológica para a caracterização de materiais poliméricos na escala nanométrica. / [en] Over the past few decades, more intensely, atomic force microscopy (AFM) has been used in research and development activities, notably for the characterization of materials. Despite the advances and sophistications of the technique, the determination of the modulus of elasticity of polymeric materials remains a challenge given the complexity of characterizing complex materials, commonly generating significant spread in the measurement results. This research presents mappings of the morphology and measurements of the elasticity modulus of commercial cellulose (bamboo and eucalyptus fibers) and lignocellulosic, referenced to already characterized synthetic polymeric materials (considered as standard). Atomic force microscopy (AFM), in the peak force tapping mode, alternatively based on the Derajaguin-Muller-Toporo model, DMT (which is the model incorporated by Bruker in its AFM software) and the Johnson-KendallRobert model, JKR (proposed in this work, using a Matlab algorithm), was used as a technique for measuring the elasticity module of the investigated materials. From the tests performed, it was possible to evaluate the measurement method based on metrological criteria and determine the most appropriate calculation model for the characterization of the investigated materials. For the standard materials used as a reference, whose elasticity modulus values are reported by the respective suppliers (E equal 2.7 more or less 0.1 GPa, for polystyrene and E equal 1.8 GPa, for polyamide), the JKR model proved to be most suitable to support the calculation of the modulus of elasticity. While the JKR model reproduced the manufacturer s value with 6.3 percent, for the case of polystyrene (E equal 2.540754 more or less 0.056 GPa) and with 12.5 percent, for the case of polyamide (E equal 1.680050 more or less 0.041 GPa), the DMT model produced results with deviations greater than 50 percent from the reference value taken as standard reference values. Based on these DMT and JKR models, the work evaluated the elasticity module of other materials, more specifically: (i) cellulose film extracted from eucalyptus; (ii) commercial microfiltered cellulose film; (iii) microfibrillated cellulose film, deposited in the laboratory by and ultrasound technique and (iv) samples of bamboo (Dendrocalamus Giganteus), extracted from the external and internal section of the bamboo stem. The results are discussed in accordance with the metrological rigor of the stochastic and deterministic components of the uncertainty associated with the measurements performed, confirming that the atomic force microscopy (AFM), in the peak force tapping mode, presents itself as a promising technique to be used as a metrological tool for the characterization of polymeric materials at the nanoscale.

Page generated in 0.0256 seconds