• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] CHARACTERIZATION OF ACTUATORS BASED ON POLYMERIC ARTIFICIAL MUSCLES WITH CAPACITIVE EFFECT / [pt] CARACTERIZAÇÃO DE ATUADORES BASEADOS EM MÚSCULOS ARTIFICIAIS POLIMÉRICOS POR EFEITO CAPACITIVO

PEDRO FERREIRA DA COSTA BLOIS DE ASSIS 07 April 2008 (has links)
[pt] É notória a necessidade de encontrar novas tecnologias para atuação de sistemas robóticos tão eficazes quanto a do músculo natural. Os atuadores tradicionais possuem grande agilidade e força quando comparados aos músculos naturais, mas suas dimensões e peso são elevados em relação à força que são capazes de exercer, e demandam muita energia para cumprirem suas tarefas. Manipuladores robóticos menores e mais baratos poderiam existir se pudessem utilizar músculos naturais para impulsioná-los. Ao mesmo tempo, as indústrias gastariam menos com os custos envolvidos em energia e compra desses manipuladores. Este trabalho estuda o comportamento de músculos artificiais baseados no polímero acrílico VHB4905, através da construção de uma bancada de teste com sensor de força, incluindo especificação de todos os equipamentos e o desenvolvimento de circuitos de alta tensão (até 10kV) para acioná-los. Durante o desenvolvimento e implementação do circuito foram encontrados problemas intrínsecos à manipulação de tensões da ordem de vários kV. Esses problemas foram apontados e soluções satisfatórias foram implementadas, de forma a tornar os experimentos possíveis. Modelos matemáticos de algumas das principais configurações possíveis para atuadores foram desenvolvidos. Os modelos desenvolvidos para uma das configurações típicas foram comparados com resultados experimentais com um erro máximo absoluto de 1% (26,7mN) do valor real. Experimentos em atuadores de molduras fixas foram feitos com resultados de 223% de deformação da região ativa, com desempenho muito superior ao dos músculos naturais. A partir de um dos modelos desenvolvidos, implementou-se um controlador PID compensado que gerou melhores resultados a entradas em degrau que o PID padrão, o qual não leva em consideração a não linearidade e a alta sensibilidade do atuador quando submetido a tensões próximas da tensão de quebra do dielétrico. A eficácia da técnica de controle proposta foi comprovada experimentalmente. / [en] It is well known the needs of finding new technologies for robotic systems actuations, with the same efficiency of the natural muscles. The common actuators have better agility and force when compared to natural muscles, but the dimensions and weight are bigger and for that the demand of energy necessary for the actuation is higher. Smaller and cheaper robot manipulators could exist if they were able to use natural muscles to drive them. At the same time, industries would spend less money with energy and manipulators. This work studies the behavior of artificial muscles based on dielectric elastomers (VHB4905) through the development of a test bench with force transducer, including the specification of all the equipments and the development of a high voltage circuit (10kV maximum). During the development and implementation of the circuit, problems inherent to high voltage manipulation were found. Those problems were shown and tolerable solutions were taken, so that the experiments were feasible. Mathematic models of some of the main configurations for actuators were developed. One of those models (from a typical configuration) was compared with experimental results with a maximum absolute error of 1% (26.7mN) of the real value. Experiments with fixed frame actuators were made with 223% of strain, showing a much higher performance compared to natural muscles. With one of the mathematic models, a PID controller with adjustable gains was developed and presented better results, for a step response, when compared to a standard PID controller. This last one do not take into account the non-linearities and for that it behaviors with great sensibility when subjected to high voltages (close to dielectric breakdown). The effectiveness of the proposed control technique was proved experimentally.
2

[en] TORQUE CONTROL OF AN EXOSKELETON ACTUATED BY PNEUMATIC ARTIFICIAL MUSCLES USING ELECTROMYOGRAPHIC SIGNALS / [pt] CONTROLE DE TORQUE DE UM EXOESQUELETO ATUADO POR MÚSCULOS PNEUMÁTICOS ARTIFICIAIS UTILIZANDO SINAIS ELETROMIOGRÁFICOS

JOAO LUIZ ALMEIDA DE SOUZA RAMOS 21 November 2013 (has links)
[pt] A robótica aplicada à reabilitação e amplificação humana está em uma fase iminente de se tornar parte de nossa vida diária. A justaposição da capacidade de controle humana e o poder mecânico desenvolvido pelas máquinas oferecem uma promissora solução para auxílio físico e de amplificação humana. O presente trabalho apresenta um exoesqueleto ativo para membros superiores controlado por uma alternativa e simples Interface Homem-Máquina (HMI) que utiliza o Modelo Muscular de Hill para aumentar a força e resistência mecânica do usuário. Músculos Pneumáticos Artificiais (PAM) são utilizados como atuadores por sua alta razão entre potência e peso e atuam o sistema através de um esquema com cabos de aço. Algoritmos Genéticos (GA) aproximam localmente os parâmetros do modelo matemático do atuador e o modelo fisiológico do músculo, que utiliza sinais eletromiográficos superficiais (sEMG) para estimar o torque na articulação do exoesqueleto. A metodologia proposta oferece três vantagens principais: (i) reduz o número de eletrodos necessários para monitorar a atividade muscular, (ii) elimina a necessidade de transdutores de força ou pressão entre o exoesqueleto e o usuário ou o ambiente e (iii) reduz o custo de processamento em tempo-real, necessário para implementações de sistemas embarcados. O exoesqueleto é restrito ao membro superior direito e a estratégia de controle é avaliada verificando o desempenho do usuário ao manipular uma carga de 3.1kg estática e dinamicamente com e sem o auxílio do equipamento assistivo. / [en] Robotics for rehabilitation and human amplification is imminent to become part of our daily life. The juxtaposition of human control capability and machine mechanical power offers a promising solution for human assistance and physical enhancement. This work presents an upper limb active exoskeleton controlled by an alternative and simple Human-Machine Interface (HMI) that uses a Hill Muscle Model for strength and endurance amplification. Pneumatic Artificial Muscles (PAM) are used as actuators for its high power-to-weight ratio and to drive the system through a cable arrangement. Genetic Algorithms (GA) approach locally optimizes the model parameters for the actuator mathematical model and the physiologic muscle model that uses the surface electromyography (sEMG) to estimate the exoskeleton joint torque. The proposed methodology offers three main advantages: (i) it reduces the number of electrodes needed to monitor the muscles, (ii) it eliminates the need for user force or pressure sensoring, and (iii) it reduces the real-time processing effort which is necessary for embedded implementation and portability. The exoskeleton is restricted to the right upper limb and the control methodology is validated evaluating the user performance while dynamically and statically handling a 3.1kg payload with and without the aid of the assistive device.

Page generated in 0.0281 seconds