• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] DETERMINATION OF SILICON AND ALUMINUM IN CRUDE OIL USING ENERGY DISPERSIVE X-RAY FLUORESCENCE SPECTROMETRY / [pt] DETERMINAÇÃO DE SILÍCIO E ALUMÍNIO EM PETRÓLEO POR ESPECTROMETRIA DE FLUORESCÊNCIA DE RAIOS-X POR DISPERSÃO DE ENERGIA

MARLIN JEANNETTE PEDROZO PEÑAFIEL 15 May 2018 (has links)
[pt] A determinação de diferentes níveis de silício e alumínio em petróleo é importante porque pequenas quantidades destes elementos podem produzir efeitos adversos nas refinarias devido à corrosão de equipamento ou afetar a qualidade dos produtos refinados. A espectrometria de fluorescência de raios-X por dispersão de energia (EDXRF) foi utilizada para desenvolver um método para a determinação de Si e Al em petróleo, onde estes elementos se encontram principalmente sob a forma de partículas sólidas de aluminossilicatos dispersas na amostra. Uma vez que os analitos não puderam ser determinados sem interferência diretamente no óleo, a fusão das amostras de petróleo foi realizada utilizando tetraborato de lítio. Em seguida, as amostras fundidas foram colocadas no centro de papéis de filtro de 10 mm de diâmetro, que foi colocado entre duas folhas de filme de polipropileno, para então ser fixado à cubeta para as medições no instrumento. A quantificação foi feita por meio de curvas analíticas no intervalo de concentração de 0 a 40 mg kg(-1) (para ambos os elementos) no material fundido final. O método desenvolvido, não sofreu interferência matriz uma vez que as amostras foram completamente decompostas e, posteriormente secas no substrato. Os resultados para os elementos foram estatisticamente comparáveis com os obtidos por espectrometria de absorção atômica com chama (FAAS). Além disso, os resultados concordaram com os obtidos nas amostras de programas de proficiência da ASTM. Amostras reais de petróleo, fornecidas pela Petrobras, também foram analisadas. As recuperações alcançadas se encontram entre 71 e 100 por cento para as diferentes amostras, o qual pode ser considerado satisfatório devido à dificuldade em se determinar esses elementos. Os limites de quantificação (10 vezes o desvio-padrão, n=10) encontrados para o Si e Al no petróleo foram de 0,7 e 1,1 mg kg(-1), respectivamente, mostrando o potencial do método proposto para a determinação de amostras com valores mais elevados destes elementos. / [en] It is important to determine silicon and aluminum at different levels in crude oils because of trace amounts of these elements may produce adverse effects in oil refining either by causing corrosion or by contaminating and affecting the quality of the refined products. Energy dispersive X-ray fluorescence spectrometry (EDXRF) was used to enable a reliable method for determination of Si and Al in crude oil, where these elements are found mainly in the form of solid aluminosilicate particles dispersed in the sample. Since the analytes could not be determined directly in the oil without interference, the fusing the crude oil samples was made using lithium tetraborate. Then, the fused samples were placed in the center of 10 mm diameter filter paper that were sandwiched between two polypropylene film foils and attached to the instrument cell for measurements. Quantification was made by using analytical curves in the concentration range from 0 to 40 mg kg (-1) (for both elements) in the final fused material. The method developed did not suffer from matrix effect once the sample matrix was completely decomposed and the sample solution dried in the substrate before measurements. The results for the elements were statistically comparable to the ones obtained by flame atomic absorption spectrometry (FAAS). In addition, for proficiency test samples, the results were in accordance to the ones reported by ASTM proficiency programs. Real samples of oil provided by Petrobras Company also were analyzed. Recoveries were achieved between 71 and 100 percent for different samples, which can be considerable satisfactory because of the difficulty in determine those elements. The limits of quantification (10 times the standard deviation. N = 10) found for silicon and aluminum in the oil were of 0.7 and 1.1 mg kg (-1), respectively, showing the potential of the proposed method to screen for samples with higher amounts of these elements.

Page generated in 0.0292 seconds