• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 1
  • Tagged with
  • 23
  • 23
  • 23
  • 23
  • 23
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

[en] ENERGY SPREAD IN VIBRATION ISOLATION SYSTEMS / [pt] TRANSFERÊNCIA DE CALOR EM ESCOAMENTO LAMINAR DE MATERIAIS VISCOPLÁSTICOS ATRAVÉS DE ESPAÇOS ANULARES

EDSON JOSE SOARES 31 May 2016 (has links)
[pt] Muitas indústrias usam em seus processos materiais viscoplásticos. Esses materiais possuem propriedades que dependem fortemente da temperatura. Não é incomum encontrar processos envolvendo escoamentos não isotérmicos de materiais viscoplásticos. Nesses casos, informações sobre a transferência de calor são extremamente necessárias para um bom atendimento e aperfeiçoamento das operações. Fluidos de perfuração são tipicamente suspensões aquosas, e, por consequência, de natureza viscoplástica.Tais fluidos devem possuir densidade correta para manter a integridade física dos poços e evitar a produção prematura de hidrocarbonetos. Além disso, suas propriedades reológicas devem garantir a capacidade de arraste das partículas de rocha geradas durante o processo de perfuração, com um mínimo de potência de bombeamento. Tais particularidades requerem fluidos com baixas viscosidades a altas taxas de cisalhamento, que ocorrem em regiões próximas à parede, e altas viscosidades quando as taxas de deformação são baixas, o que ocorre na vizinhança do cascalho. Materiais viscoplásticos apresentam este tipo de comportamento. Portanto, o sucesso do processo de extração do petróleo depende do conhecimento e controle das propriedades reológicas dos fluidos de perfuração, as quais são fortemente dependentes da temperatura. Por esse motivo, a determinação do campo de temperatura no fluido de perfuração em escoamento faz-se necessária ainda em nível de projeto, o que só é possível com o conhecimento dos coeficientes de troca de calor. Estuda-se neste trabalho o problema da transferência de calor na região de entrada de escoamentos laminares de fluidos viscoplásticos através de espaços anulares. O comportamento do material é representado pelo modelo do fluido Newtoniano generalizado, com a função viscosidade descrita pela equação de Herschel-Bulkley. As equações de conservação são resolvidas numericamente via o método de volumes finitos. Investigam-se os efeitos (no coeficiente de troca de calor) da tensão limite de escoamento, índice power-law, razão de aspecto e dos números adimensionais de Reynolds e Peclet. Dentre outras conclusões, mostra-se que o números de Nusselt é uma função muito fraca das propriedades reológicas, desviando-se muito pouco dos valores Newtonianos. Surpreendentemente, esta conclusão contrasta-se fortemente com o comportamento observando em escoamentos de materiais viscoplásticos através de tubos. Convém enfatizar a importância desse fato no que tange a projetos de processos. / [en] There are many industries that use in their processes viscoplastic materials. These materials have properties that strongly depend on temperature. It is not uncommon to find processes involving the non-isothermal flow of viscoplastic materials. For these cases, heat transfer information is needed to allow reliable process designs. Drilling muds are typically aqueous suspensions and, consequently, viscoplastic in nature. They must have the correct density to provide the pressure needed for well integrity, and for avoiding premature production of hydrocarbons. Their rheological properties must be such as to aloe carrying the drill chips with a minimum of pumping power. This requires a highly shear-thinning rheological behavior. Also, the success of a well cementing operation depends to a great extent on the knowledge and control of cement rheological properties, which are also temperature dependent. In this work, heat transfer in the entrance-region flow of viscoplastic materials through annular spaces is analyzed. The flow is laminar, and the material is assumed to behave as a Generalized Newtonian fluid, with a Herschel-Bulkley viscosity function. The conservation equations are solved numerically via a finite volume method. The effect on heat transfer of yield stress, power-law exponent, aspect ratio and dimensionless Peclet and Reynolds numbers is investigated. Among other findings, it is shown that the Nusselt number is a rather weak function of the rheological properties, deviating very little from the Newtonian values. Surprisingly, this stands in strong contrast to the behavior observed for flows of viscoplastic materials through tubes. It is worth noting that this finding has important consequences in process design.
12

[en] HEAT AND MASS TRANSFER COOLING OF A VERTICAL SURFACE BY A LIQUID FILM WITH AIR FLOW / [pt] TRANSFERÊNCIA DE CALOR E MASSA NO RESFRIAMENTO DE UMA SUPERFÍCIE VERTICAL ATRAVÉS DE UM FILME LÍQUIDO COM ESCOAMENTO DE AR

MARIA REGINA DA SILVA GALETTI 12 April 2012 (has links)
[pt] Uma das características das alternativas consideradas para o desenvolvimento de reatores nucleares com características avançadas de segurança consiste na utilização de resfriamento do vaso de contenção com um fluxo de água vindo de seu topo. Este sistema forma um escoamento de um filme líquido evaporando sobre uma superfície metálica aquecida com ar escoando em contra-corrente. O presente trabalho consiste no desenvolvimento de um modelo analítico e numérico da transferência de calor e massa que ocorre na interface entre o filme líquido e a mistura ar-vapor, neste tipo de escoamento e também em escoamentos co-correntes. Devido à ausência de dados experimentais, o modelo é validado através de comparações com resultados analíticos disponíveis na literatura para situações próximas aos casos de interesse. A influência de diversos parâmetros geométricos e operacionais é analisada e são fornecidos resultados para os números de Nusselt e de Sherwood observados na interface do escoamento das fases. / [en] The design of so called Advanced Nuclear reactors includes many features of passive safety, one of them being a water flow system for cooling the containment vessel. This system generates a counter-current flow pattern with a downward liquid film evaporating over the heated vessel surface and na upward stream of air. This work presents an analytical and numerical model for analysis of heat and mass transfer occuring in the interface formed by water film surfece anda ir-vapor mixture in counter-curent and parallel flows. Due to the lack of experimental data, the model is validated throught comparisons with analytical results found in the flow analysed and the results for Nusselt and Sherwood numbers are presented.
13

[en] HEAT AND MASS TRANSFER BETWEEN LIQUID FILM AND AIR STREAM / [pt] TRANSFERÊNCIA DE CALOR E MASSA ENTRE FILME LÍQUIDO E CORRENTE DE AR

PAULO MURILLO DE SOUZA ARAÚJO 18 October 2012 (has links)
[pt] O objetivo deste trabalho é analisar as transferências de momentum, calor e massa num canal bidimensional inclinado, onde escoam um filme líquido descendente e uma corrente turbulenta de ar de sentido oposto, ou de mesmo sentido oposto, ou de mesmo sentido. O filme líquido, suposto laminar, consiste numa solução fraca, ou degenerada, de trietileno glicol em água. A placa inferior do canal é mantida aquecida numa temperatura uniforme, de modo a facilitar a remoção de água do líquido para a fase gasosa. A corrente de ar deve ser turbulenta, para garantir taxas convenientes da massa de água transferida. Considera-se, não obstante, a possibilidade do ar também escoar liminarmente. A placa superior do canal, ou cobertura é adiabática e ambas as placas são impermeáveis à transferência de água. A parte hidrodinamica do problema é resolvida separadamente. Atribui-se maior importância à determinação dos perfis de temperatura e concentração de águas nas duas fases. Pretende-se que a aparelhagem acima descrita opere como um regenerador da substância líquida higroscópica, tendo este sido previamente usado num secador de ar, em aplicação de fim industrial ou agrícola. A tarefa proposta pelo problema é a simulação das condições operativas do trocador de massa. Como resultado desta simulação, tenciona-se predizer os valores dos coeficientes de transferências de calor e massa, variando amplamente as taxas de escoamento, tanto da fase gasosa, quanto da líquida. Na verdade, diversos pesquisadores têm revelado, nos últimos anos, um grande interesse no estudo de regeneradores do tipo aqui analisado. Toda vez que se tem disponibilidade de energia a temperaturas moderadas e baixo custo, como energia solar ou calor de rejeito industrial, parece indicado regenerar desta forma o desumidificante líquido nas instalações de condicionamento de ar por resfriamento evaporativo. Estabelecidas as equações diferenciais parciais do problema e as condições de contorno pertinentes, elas são resolvidas através de algoritmos obtidos por diferenças finitas, dentro do enfoque de volumes de controle. O procedimento numérico é interativo, usando-se o computador digital na obtenção da solução. Verifica-se que os resultados se mantêm dentro da analogia entre transferência de calor e massa, conforme era esperado. A partir dos resultados, podem-se estabelecer algumas correlações para os principais parâmetros do problema. Propõe-se, por fim, uma metodologia para o projeto do equipamento. Para isto, não é necessário fazer uso direto do método numérico, pois existem algumas poucas equações analíticas, simples, que podem ser facilmente manipuladas num microcomputador ou, até mesmo, numa calculadora eletrônica. Estas equações são deduzidas a partir da aplicação da teoria de penetração ao problema. As correlações dos resultados numéricos são, entretanto, essenciais ao bom emprego da teoria penetração. / [en] The combined momentum, heat and mass transfer is analysed in a two domensional inclined channnel for a countercurrent, or co-current turbulent air strem flowing past a liquid falling film. The film flow, supposed to be laminar, consists of a weak, or co-current tubulent air stream flowing past a liquid falling film. The film flow, supposed to be laminar, consists of a weak, or degenerate, solution of triethylene glycol and water. The film flow, supposed to be laminar, consists of a weak, or degenerate, solution of triethylene glycol and water. The lower plate of the channel is maintained at a constant, relatively high from the liquid to the gas phase. The stream of air is usually turbulent, thus assuring convenient rates of tranferred mass of water. Nevertheless, the possibility of laminar flow in the gas is not avoided. The second plate of the channel is considered as adiabatic and both plates are impervious to water. The hydrodynamic part of the problem is solved separately, and the determination of temperature and concentration of water profiles in the two phases is of major importance. The apparatus above described is intended to be a regenerator of the hygroscopic liquid, previously used in an air dryer, for industrial or agricultural purposes. The tash suggested by the problem is then to simulate the conditions, under which this mass exchanger will operate. Following the simulation, heat and mass transfer coefficientes can be predicted for a large range of flow rates of both gas an liquid phases. In fact, in recent years several investigators have manifested an increasing interest in developing studies of such equipment. In situations where a source of energy at low temperature is freely available, and this is the case of solar energy or industrial rejects, the employment of liquid dehumidifier regenerators is particularly attractive for evaporative cooling air conditioning systems. The partial differential equations of the problem, accompanied by suitable boundary conditions, are solved by a finite difference scheme, based on the volume of control approach. There are iterative procedures involved and solutions is reached in a mainframe computer. The results seem to be in accordance with the expected analoggy between heat and mass transfer. Some correlations are presented for the principal parameters of the problem. Lastly, a methodology is proposed for the design of the equipment. In spite of the complexity of the problem, it is possible to provide the user with a few simple analytic equations, which can be solved in any micro-computer or even in a pocket calculation. Theses equations arise from the employment of the penetration theorym briefly discussed and compared with numerical results. Indubitably, the use of this theory must be in compliance with the previously obtained numerical correlations.
14

[en] HEAT TRANSFER AND HEAD LOSS IN THE TURBULENT FLOW OF INTERNALLY RIBBED TUBES / [pt] TRANSFERÊNCIA DE CALOR E PERDA DE CARGA NO ESCOAMENTO TURBULENTO EM DUTOS INTERNAMENTE ANELADOS

MARCOS HENRIQUE DE PINHO MAURICIO 13 March 2018 (has links)
[pt] Os coeficientes de transferência de calor e os dados de perda de carga foram determinados experimentalmente, para o escoamento turbulento, em dutos circulares providos internamente de anéis transversais. Os resultados foram obtidos tanto para a região de entrada como na região totalmente desenvolvida. Foram investigados os efeitos da altura do anel, do espaçamento entre os anéis e do número de Reynolds. Variou-se o número de Reynolds de 5.000 a 75.000, enquanto que a faixa de passo p/H foi de 4 a 15. Duas alturas do anel foram estudadas, a saber, 0,05 e 0,10 vezes o diâmetro interno do tubo. O fator de atrito para as geometrias periódicas mostrou ser sempre bem superior ao fator de atrito para o tubo liso, crescendo rapidamente com H/D. Para os tubos com anéis de pequena altura, o fator de atrito decresce com o aumento do passo, enquanto o oposto é observado para os tubos com anéis maiores, na faixa pesquisada. Para H/D = 0,05, o coeficiente de transferência de calor é máximo para valores de p/H em torno de 10 e para baixos números de Reynolds. Para H/D e 0,10, o maior coeficiente de transferência de calor medido foi para p/H = 10, que mostrou ser praticamente independente do número de Reynolds. Uma comparação de desempenho entre os tubos anelados e liso foi realizada sob dois tipos de restrições, a saber, a iguais vazões mássicas e iguais potências de bombeamento. Os tubos anelados mostraram um melhor desempenho em todos os casos pesquisados, exceto para H/D = 0,10 com Re > 60.000. / [en] Heat transfer coefficients and pressure drop data were determine experimentally for turbulent flow in circular ducts equipped with internal transverse ribs. Both fully developed and entrance region results were obtained. The effects of the rib height, rib spacing, and Reynolds number were investigated. The Reynolds number ranged from 5,000 to 75,000, whereas the pitch p/H was varied in the range 4 to 15. Two rib heights were investigated, namely, 0.05 e 0,10 times the tube inside diameter. The friction factor for the periodic geometric was found to be always much larger than the smooth tube friction factor, increasing rapidly with H/D. For the tubes with short ribs, the friction factor decreases with increasing pitch, but the opposite is true for the tall ribbed tubes in the range investigated. For H/D = 0.05, tha heat transfer coefficient is highest for values of p/H around 10 and low Reynolds number. For H/D = 0,10, the highest heat transfer coefficients measured were for p/H = 10, where it was found to be nearly independent of the Reynolds number. Performance comparisons between the ribbed and smooth tubes were made under two types of constraints, namely, equal mass flow rate and equal pump power. It was found that the ribbed tubes have higher heat transfer perFormance for all cases investigated, except for H/D = 0.10 with Re > 60,000.
15

[en] HEAT TRANSFER IN NON-NEWTONIAN FLUID FLOW THROUGH AN ABRUPT HIRING / [pt] TRANSFERENCIA DE CALOR NO ESCOAMENTO DE FLUIDOS NÃO NEWTONIANOS ATRAVÉS DE UMA CONTRATAÇÃO ABRUPTA

MARCIO DA SILVEIRA CARVALHO 27 January 2012 (has links)
[pt] O trabalho analisa a transferência de calor no escoamento de fluidos não-newtonianos através de uma contração abrupta circular de razão 4:1, com temperatura prescrita nas paredes sólidas. O escoamento de fluidos elásticos nesta geometria apresenta uma região de recirculação bem maior que no caso de fluidos Newtonianos. Esta alteração no padrão do escoamento altera significativamente o processo de transferência de calor. O escoamento representa uma boa modelagem do processo de extrusão de líquidos poliméricos. Resolvem-se as equações de conservação de momentum e energia desacopladamente, já que foi adotadas a hipótese de não variação das propriedades do fluido com a temperatura. A relação tensão – taxa de deformação foi feita através de dois modelos constitutivos, Newtoniano generalizado e Maxwell convectado. A hipótese de escoamento lento não foi adotada, como é usualmente feito na literatura da área. Deste modo, analisa-se separadamente a influencia dos efeitos elásticos e inerciais. As equações diferenciais foram integradas numericamente pelo método dos volumes finitos e o aclopamento velocidade\ pressão foi feito através do algoritmo SIMPLE. Pelos resultados obtidos, observa-se a importância da modelagem não newtoniana e da inclusão dos termos inerciais no estudo do escoamento e da transferência de calor no processo de extrusão de polímeros. / [en] It is well known that the flow of a non-Newtonian fluid through a sudden contraction exhibits a vortex in the corner region bigger than the one observed in the corresponding flow of a Newtonian Fluid. This change of pattern of the flow affects significantly the heat transfer at the wall. It was investigated the case og a a 4:1 circular contraction, with uniform temperature distrubuition at the solid walls. This problem represents a first approach for the analysis of the polymeric liquids extrusion process. The flow and temperature field have been obtained from the numerical integration of the conservation equations. To account for the flow dependence of the stress tensor, a generalized Newtonian model and a convected Maxwell model have been employed. The creeping flow hypothesis has not been adopted, so it was possible to analyse the elastic effects and the inertial effects separately. The nuemerical solution have been obtained via a finite-volume method. The results show the importance of the non-Newtonian modeling and of the inclusion of inertial terms in the study of the flow and beat transfer in the polymeric liquids extrusion process.
16

[en] NUMERICAL HEAT TRANSFER ANALYSIS OF A STEEL RIBBON SUBJECTED TO HEATING IN A CONTINUOUS FURNACE / [pt] ANÁLISE NUMÉRICA DA TRANSFERÊNCIA DE CALOR NUMA TIRA DE AÇO SUBMETIDA A AQUECIMENTO EM FORNO CONTÍNUO

ADELMO CRESPO MACHADO 03 October 2012 (has links)
[pt] Na presente tese, a equação de energia é resolvida para uma tira de aço bi-dimensional que se move com velocidade constante através de um forno contínuo e é submetida a várias condições diferentes de radiação de convecção. As equações de discretização foram obtidas utilizando a técnica de diferenças finitas com enfoque em volume de controle. O conjunto destas equações indicou os sete parâmetros adimensionais do problema. Por se tratar de uma equação elíptica, a solução foi inicialmente encaminhada para a determinação dos comprimentos de tira antes e após o forno, além dos quais desapareceria o efeito da condução de calor axial no interior da tira. Os resultados mostraram a possibilidade de substituição da condição de contorno após o forno, passando-se então a considerar uma seção transversal da tira situada próxima à saída do forno. A nova condição de contorno foi estabelecida por um balanço de fluxos de calor por condução, convecção e emissão radiativa na referida seção da tira. A partir da análise de influência de cada parâmetro adimensional sobre a distribuição e temperatura da tira, foram selecionados como mais importantes o número de Peclet relativo à taxa de produção do forno, o parâmetro de radiação incidente relativo ao consumo de combustível e parâmetro geométrico que exprime a razão entre as dimensões da tira. Uma análise da eficiência na transferência de calor foi então realizada, avaliando os citados parâmetros diante dos requisitos de obtenção de uma determinada temperatura média da tira e de uma elevada homogeneidade de temperatura em sua reação transversal localizada próxima à saída do forno. Ao promover-se a divisão do forno em três zonas e a adoção de diferentes fluxos de radiação incidente, foi possível simular situações operacionais típicas que ocorrem nos fornos de reaquecimento de placas de uma usina siderúrgica e efetuar comparações com dados disponíveis em literatura. / [en] In the present thesis the energy equation is solved for the temperature distribution in a two dimensional steel strip, which moves with Constant velocity through a furnace and is submited to several different radiation and convection fluxes. Steady state conditions are supposed to exist, if the reference frame is attached to the furnace walls. Thus, one more term arises in the energy equation to take into account the strip movement. The non-linearity of the problem is restricted to the radiation boundary conditions. The discretized algebraic equations are set up, utilizing a finite difference, scheme with the control volume approach. The complete set of equations has shown that there are seven non-dimensional parameters to be specified. Due to the elliptic nature of the equation, it was stabilished that at some distance before and after the furnace, the axial heat conduction in the strip would vanish. A first attempt was done in order to find these distances. The results have shown that the boundary condition after the furnace, the axial heat conduction in the strip would vanish. A first attempt was done in order to find these distances. The results have shown that the boundary condition after the furnace could be substituted, taking a section of the strip closer to the furnace outlet and simply stating the heat flux balance in terms of conduction, convection and radiant emission, considering that this is an end of the strip. Examining the resultant temperature profiles and the heat exchanged by the strip, the influence of each non-dimensional parameter was investigated. Three of them are believed to be the more important: the péciét number related to the furnace rate of production, the incident radiation parameter related to the rate of fuel consumption and the geometrical aspect ratio of the strip. A thermal abalysis of the furnace was then carried out, in order to achieve prescribed data on averade temperature of the strip at the furnace outlet, degree od temperature homogenelty in the strip and heat transfer efficiency. To make a more realistic simulation of the furnace, it was also subdivided into three cones of different incident radiation fluxes and then typical operational situations could be reproduced, as they usually occur in slab reheating furnaces. These simulations were compared with data available in the literature, showing a reasonable qualitative accordance with them.
17

[en] THEORETICAL AND EXPERIMENTAL ANALYSIS OF COOLING TOWERS AND AIR WASHERS / [pt] ANÁLISE TEÓRICO-EXPERIMENTAL DE TORRES DE RESFRIAMENTO E LAVADORES DE AR

MARCOS SEBASTIAO DE PAULA GOMES 08 October 2012 (has links)
[pt] Investigou-se teórica e experimentalmente o comportamento dos equipamentos de transferência de calor e massa conhecidos como Torre de Resfriamento e Lavador de Ar. Para a torre, analisa-se um modelo de simulação, a partir de equações diferenciais ordinárias obtidas através de balanços de energia e massa em um elemento infinitesimal de volume, baseado em propriedades uniformes em uma mesma seção transversal, sendo, portanto unidimensional. O sistema resultante é resolvido numericamente. Já para o lavador de Ar, obtem-se, através dos mesmos balanços juntamente com a hipótese de temperatura da água constante, uma solução analítica. Montou-se, com o intuito de validação do modelo, um sistema experimental onde os parâmetros de interesse pudessem ser medidos e desta forma comparados com os resultados numéricos. A concordância entre valores foi bastante boa, para a faixa investigada. Este mesmo sistema permitiu que se obtivessem dados reais a respeito da operação tanto da torre como do lavador, e como consequência a determinação do produto coeficiente de transferência de massa pela área de troca (Hd Av), para cada caso. Finalmente, apresentam-se correlações para o cálculo deste parâmetro como função das vazões de ar e da área da seção transversal, as quais podem ser utilizadas em projetos futuros destes equipamentos. / [en] In the present work the cooling tower and the Air Washer were investigated, experimentally and theoretically. The one-dimensional model developed to simulate the cooling tower operation was based on mass and energy balances written for a differential colume. The resulting system of differential equations was solved numerically. For the Air Washer, the energy and mass balances, incorporating the assumption of constant water temperature, led to a system of equations wich was solved analytically. The experiments conducted were aimed at validating the models developed. The experimental results obtained were in very good agreement with the predictions, within the range of parameters investigated. Correlations were developed relating average mass transfer coefficient for the equipments with the water and air flow rates.
18

[en] HEAT TRANSFER IN TURBULENT SWIRL FLOW THROUGH RECTANGULAR DUCTS / [pt] TRANSFERÊNCIA DE CALOR PARA ESCOAMENTO ESPIRALADO TURBULENTO EM DUTOS RETANGULARES

ANTONIO CARLOS RIBEIRO NOGUEIRA 21 July 2015 (has links)
[pt] O presente trabalho investigou numericamente e experimentalmente as características de transferência de calor e queda de pressão de um escoamento espiralado, turbulento, de caindo através de um duto retangular de elevada razão de aspecto. A condição de escoamento espiralado na estrada do duto foi obtida por meio de tubos paralelos contendo fitas torcidas de modo a produzir vórtices girando em sentidos opostos, dois a dois. Coeficientes de transferência de calor locais e médios foram determinados através da utilização da técnica de sublimação de naftaleno em conjunto com a anologia entre processos de transferência de calor e massa. Os valores locais foram medidos sobre toda a superfície ativa do duto, com o auxílio de uma mesa de coordenadas controlada por microcomputador. Resultados para os coeficientes transferência de calor e da queda de pressão foram obtidas para três valores do número de Reynolds do duto e para três valores da intensidade do escoamento espiralado, dados pela utilização de fitas torcidas com diferentes relações de passo/diâmetro. Para posições axiais próximas da entrada do duto, os resultados revelaram altas taxas de aumento na transferência de calor, relativamente ao caso base, representado por escoamento turbulento sem a imposição do escoamento espiralado. Os resultados para a queda de pressão demonstraram que a presença da componente tangencial da velocidade do escoamento espiralado imposto reduziu os efeitos de recuperação de pressão existentes na região de entrada de dutos com entrada abrupta. Foi também verificado que o comprimento de desenvolvimento hidrodinâmico do escoamento aumenta com a intensidade do escoamento espiralado. As equações de conservação de massa , movimento linear e energia, incorporadndo o modelo de turbulência K – E foram resolvidas numericamente para a configuração em estudo. Os resultados numéricos apresentaram boa concordância com os experimentos, permitindo a / [en] The presente work investigated experimentally and numerically the heat transfer and pressure drop characteristics of turbulent decaying swirl flows through a rectangular duct of high aspect ratio. The swirl flow inlet condition was obtained by a set of parallel tubes with twisted-tape inserts wich produced pairs of counterrotating vortices. Local and average heat transfer coefficients were determined by the utilization of the naphthalene sublimation technique in conjunction with the analogy between heat and mass transfer. Local result were obtained along the whole active surface of the duct, utilizing a computer-assisted coordinate table and depth gage. The study encompassed the investigation of the local and average heat transfer coefficient distribution and pressure drop, for three values of the duct Reynolds number, and for three values of the swirl intensity given by different tape pitch-to-diameter rations. The results showed regions of high heat transfer augmentation situated close to the entrance of the duct, when compared to the base case results characterized by turbulent flow through a duct without the swirl flow inlet condition. The pressure drop results demonstrated that the presence of the tangencial velocity component of the imposed swirl flow was seen to reduce the pressure recover effect present in sharp-edged entrance ducts. It was also verifyied that the hydroninamic developing length increases with the intensity of the swirl flow. The equations governing conservation of mass, linear momentum and energy were solved numerically for the configuration investigated. The K-E turbulence model was employed. The numerical results displayed good agreement with the experiments and provided additional information related to velocity and temperature fields which complemented the experimental program.
19

[en] A MATHEMATICAL MODEL FOR A CONVECTIVE HEAT TRANSFER PROCESS / [pt] MODELO MATEMÁTICO DE UM PROCESSO CONVECTIVO DE TRANSFERÊNCIA DE CALOR

JOSE MARIA GARCIA CASELLES 04 August 2008 (has links)
[pt] Este trabalho visa a modelagem de um processo convectivo de transferência de calor entre vapor de água e óleo. Estudam-se as diversas possibilidades de solução do sistema de equações diferenciais a derivadas parciais com coeficientes variáveis com o tempo, concluindo-se que o método de discretização no espaço é o de maior eficácia no caso presente. Uma vez obtido o modelo teórico aplica-se o método do modelo para a identificação dos parâmetros mediante técnicas de simulação no CSMP do computador IBM-1130. / [en] This work is concerned with the modeling of a convective heat transfer process between steam and oil. By studying the different ways of solution of two simultaneous partial differential equations with time dependent parameters, it is concluded that to lump the equations with respect to the spacial coordinates is the most useful method in the present exemple. Once the theoretical model is obtained, the model method is used to identify the parameters with the CSMP in the IBM-1130 computer.
20

[en] THERMAL HYDRAULIC ANALYSIS OF SMOOTH AND FINNED ANNULAR DUCTS / [pt] ANÁLISE TERMOHIDRÁULICA DE SEÇÕES ANULARES LISAS E ALETADAS

CARLOS VALOIS MACIEL BRAGA 28 September 2012 (has links)
[pt] O presente trabalho analisa a transferência de calor e a perda de carga em escoamento turbulento através das regiões anulares lisas e aletadas. Os coeficientes de transferência de calor foram obtidos experimentalmente, utilizando-se a teoria de trocadores de calor. Também foram determinados os coeficientes de perda de carga associados a cada uma das geometrias analisadas. Os experimentos foram realizados em um trocador de calor bi-tubular concêntrico. Água (fluído quente) escoava através do tubo interno, enquanto ar (fluido frio) fluía através da região anular. Medindo-se as vazões e temperaturas na entrada e saída da seção de teste do trocador de calor, obtém-se a efetividade da mesma e, consequentemente, o coeficiente global de transferência de calor (médio). As condições de contorno adotadas foram de temperatura uniforme na superfície externa do tubo interno e de isolamento térmico na superfície externa do tubo interno e de isolamento térmico na superfície externa da região anular. Com o objetivo de obter-se condições de escoamento completamente desenvolvido, o trocador de calor possui um comprimento, a montante da seção de testes, de aproximadamente trinta diâmetros hidráulicos. Os coeficientes de transferência de calor e de perda de carga são apresentados de forma adimensional, como função do número de Reynolds do escoamento, os resultados obtidos para as regiões anulares lisas e aletadas são comparados entre si. O propósito de tal comparação foi o de estudar a influencia das aletas na perda de carga e na taxa de transferência de calor. No caso das regiões aletadas, verifica-se que a eficiência das aletas influencia a transferência de calor. Deste modo, realizou-se uma análise bi-dimensional de transferência de calor nas aletas para obter-se a eficiência das mesmas e, consequentemente, a eficiência das regiões aletadas. Também é mostrado que o desempenho térmico da região depende principalmente do número de Nusselt e da eficiência da mesma. Tais parâmetros são apresentados, em última análise, como funções do número de Reynolds e da geometria do problema. / [en] The present work is concerned with the turbulent heat transfer and pressure drop in smooth and finned annular ducts. Average heat transfer coeeficients have been obtained by means of the heat exchanger theory. In addition, friction factors have also been determined. The experiments were performed by utiling four double-pipe heat exchangers. The average heat transfer coefficients, for air flowing in the annular section, were fertmined by measuring the overall heat transfer coefficients of the heat exchangers. In order to aatain fully developed conditions, the heat exchangers had a starting length of 30 hydrualic diameters. The thermal boundary conditions consisted of uniform temperature on the inner surface, the outer surface being insulate. The heat transfer coefficients and friction factors are presented in dimensinless forms, as functions of the Reynolds number of the fow. The results for smooth and finned annular ducts were compared. The purpose of such comparison was to study the influence of the fins on the pressure drop and heat transfer rate. In the case of the finned annular ducts, it is shown that fin efficiency has some influence on the heat transfer rates. Then a two-dimensional heat transfer analysis was performed in order to obtain the fin efficiency and the annular region efficiency. It is also shown that the overall thermal performance of finned surfaces depends mainly of the Nusselt number and on the region efficiency. These parameters are presented as functiond of the Reynolds number of the flow and the geometry of the problem.

Page generated in 0.0573 seconds