• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

[en] WELDABILITY ANALISES OF API 5L X-80 STEEL USING TEKKEN TEST AND IMPLANT TEST / [pt] ANÁLISE DA SOLDABILIDADE DO AÇO API 5L X-80 POR MEIO DOS TESTES TEKKEN E DE IMPLANTE

GISELLE CALOI 28 October 2008 (has links)
[pt] Este trabalho apresenta um estudo da soldabilidade do aço API 5L X-80 utilizando os Testes Tekken e de Implante. A pesquisa avalia a soldabilidade do aço X-80 para a soldagem circunferencial com eletrodo revestido e arame tubular com relação à formação de trincas induzidas por hidrogênio. O objetivo é viabilizar diferentes opções de processos de soldagem para o aço em questão. Para o Teste Tekken foram soldados dois pares de chapas pelo processo SMAW utilizando o consumível E8010-G e mais dois pares pelo processo FCAW-G com o consumível E101T1-GM-H8. Para o Teste de Implante foram utilizados três chapas de suporte e dez implantes, sendo que quatro implantes foram soldados pelo processo SMAW com E8010-G e seis pelo processo FCAW- G com E101T1- GM-H8. Todos os implantes apresentavam 6 mm de diâmetro. Para todos os testes a temperatura de preaquecimento foi de 100°C. A quantidade de hidrogênio difusível nos metais de solda produzidos pelos dois consumíveis foi medida pelo processo de Cromatografia Gasosa. Após a realização dos testes, todas as amostras foram observadas sem e com ataque no MO e no MEV para que as trincas induzidas por hidrogênio na ZTA e no MS (no caso do Teste Tekken) pudessem ser analisadas e medidas. A partir desse procedimento foi possível observar que todas as amostras apresentaram trincas transgranulares com comprimentos da ordem de 17,68 um, muito pequenas e improváveis de serem prejudiciais ao aço. Isso possibilita dizer que o aço X- 80 pode ser soldado utilizando os consumíveis avaliados, sem riscos de danos maiores para o material. / [en] This work shows a study of the weldability of API 5L X-80 steel using the Tekken Test and the Implant Test. The research analises the weldability of HSLA X-80 steel for orbital circunferencial welding with the Shielded Metal Arc Weld and the Flux Core Arc Weld processes with regard to hydrogen induced cracking formation. The aim is to make feasible different options of welding process for the steel at issue. For the Tekken Test two pairs of plates were welded by SMAW process using E8010-G consumable and two more pairs by FCAW- G process using E101-T1-GM-H8. The Implant Test used three base plates and ten implants, being four implants welded by SMAW process and with E8010-G consumable and six by FCAW-G process with E101T1-GM-H8 consumable. All the implants have 6 mm of diameter. For all tests the preheating temperature was 100°C. The diffusible hydrogen content deposited by both consumables was measured by the Gas Chromatography Method. After the tests all the samples were examined without and with attack by means of optical microscope and SEM to allow hydrogen induced cracking in the HAZ and in the weld metal (for Tekken Test) to be viewed and measured. By means of this procedure it was possible to observe that all samples showed transgranular cracking with length of 17,68 um, too small and unlikely to the be bad to the steel. It allows saying that X-80 steel can be welded using the consumables tested, without a risk of damage of the material.

Page generated in 0.035 seconds