• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6463
  • 104
  • 102
  • 101
  • 87
  • 78
  • 71
  • 57
  • 29
  • 11
  • 10
  • 10
  • 7
  • 4
  • 4
  • Tagged with
  • 6720
  • 3516
  • 1353
  • 889
  • 877
  • 836
  • 783
  • 730
  • 691
  • 616
  • 596
  • 569
  • 514
  • 473
  • 410
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dessalinização para produção de água potável : perspectivas para Portugal

Guerreiro, Mário Luís Ferreira Brandão January 2009 (has links)
Tese de mestrado integrado. Engenharia Civil (Especialização em Hidráulica). Faculdade de Engenharia. Universidade do Porto. 2009
2

Modelo para priorização de diretrizes de combate a crises de abastecimento urbano de água / Model for priority guidelines for facing crisis of urban water supply

Silva, Welitom Ttatom Pereira da 10 December 2012 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2012. / Submitted by Liliane Simões (miix007@gmail.com) on 2013-04-08T12:55:54Z No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-04-08T14:57:45Z (GMT) No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / Made available in DSpace on 2013-04-08T14:57:45Z (GMT). No. of bitstreams: 1 2012_WelitomTtatomPereiradaSilva.pdf: 6484091 bytes, checksum: 12b0d84b88a3140f96ac28a89d7c84d9 (MD5) / As situações de crise no abastecimento urbano de água, caracterizadas pela escassez da água e por prejuízos ambientais, sociais e à saúde da população, principalmente para a população de baixa renda, têm-se tornado algo muito comum em diversas regiões brasileiras. A pesquisa realizada tem o objetivo de apresentar uma contribuição para o planejamento do enfrentamento de crise no abastecimento urbano de água (CAUA). Para isso foi proposta uma combinação de técnicas de inteligência artificial e metodologias multicriteriais de apoio à decisão (MCDA). O desenvolvimento de ferramentas computacionais (software) para auxiliar o processo de tomada de decisão e a realização de um estudo de caso fazem parte do escopo metodológico da proposta da pesquisa. Os resultados encontrados foram os seguintes: o conhecimento de possíveis diretrizes de projeto para solução de casos de CAUA; o conhecimento de fatores influentes na CAUA; o desenvolvimento de um modelo híbrido de análise de decisão, denominado de CAUA- SAD, baseado nos princípios de similaridade vetorial, de sistemas baseados em conhecimento (sistemas especialistas) e na utilização das MCDA (métodos PROMETHEEII, TOPSIS e ELECTRE III). A avaliação da qualidade dos modelos desenvolvidos indicou um percentual de concordância de 56%, e que melhorias nos modelos podem ser obtidas por meio de refinamento nos dados de entrada, em termos de qualidade e de quantidade. As conclusões obtidas da pesquisa indicam que a abordagem adotada para o tratamento do problema pode ser considerada adequada. No entanto, problemas para a obtenção do conhecimento de especialistas humanos sugerem a continuidade dos estudos. ________________________________________________________________________________________ ABSTRACT / Crisis situations in urban water supply, characterized by water scarcity and by population health, social, and environmental damages, specially for the low-income population, have become very common in several Brazilian regions. The objective of this research is to contribute to the planning for facing crisis in urban water supply (CUWS).To achieving this goal, a combination of artificial intelligence techniques and Multiple Criteria Decision Aid (MCDA) was proposed. The development of computational tools (software) to assist the process of decision making and their application to a case study are parts of the scope of the research proposal. The following results were obtained in this research: knowledge of possible design guidelines for solving CUWS cases; knowledge of factors influencing CUWS; development of a hybrid model of decision analysis, called CUWS-SAD, based on the principles of vector similarity, knowledge-based systems (expert systems) and on the use of MCDA (PROMETHEE II, TOPSIS and ELECTRE III methods). The quality assessment of the developed models indicated concordance index of 56%, and that improvements in the models can be obtained through enhancement in the quality and quantity of the input data. The conclusions of the research indicate that the proposed approach for the problem treatment can be considered adequate. However, problems to attain knowledge of human experts suggest further investigations.
3

Avaliação da remoção de fitoplâncton e formação de trialometanos em águas de abastecimento em processo de tratamento por FAD, interoxidação e desinfecção com cloro

JUSTINO, F. F. 26 August 2010 (has links)
Made available in DSpace on 2018-08-24T22:53:11Z (GMT). No. of bitstreams: 1 tese_4362_.pdf: 2733607 bytes, checksum: ae4c4942e9fdfc938d3bd56d8eb306a0 (MD5) Previous issue date: 2010-08-26 / A presença de populações algais nos reservatórios torna mais problemática a operacionalidade dos sistemas de tratamento e pode causar impactos negativos na qualidade das águas distribuídas ao gerar sabores e odores na água e interferir no processo de clarificação. Além disto, uma das grandes preocupações ambientais e de saúde pública em lagos e represas e a floração de algas e cianobactérias produtoras de toxinas. Em águas de abastecimento, a matéria orgânica natural, as algas/microalgas e as cianobactérias e seus metabólitos, inclusive suas toxinas, são os principais precursores com os quais os halogênios reagem para formar subprodutos da cloração, entre estes os trialometanos. O processo de clarificação utilizando o sistema de flotação vem sendo utilizado para remoção de algas, cianobactérias e suas toxinas em substituição ou conjuntamente com os processos de decantação e filtração direta. Este estudo consistiu da avaliação, em escala de bancada, dos processos de coagulação e floculação com sulfato de alumínio, flotação por ar dissolvido (FAD), inter-oxidação com cloro, filtração em areia e desinfecção com cloro, com o objetivo de investigar a remoção de fitoplâncton e a formação de trialometanos em águas de abastecimento com presença de microalgas e cianobactérias. O estudo de coagulação com sulfato de alumínio resultou em regiões semelhantes de remoção (pH 6,3 e 6,5 e 25 a 35mg/L Al2(SO4)3) dos parâmetros cor aparente e cor real e turbidez para os períodos de seca (71%) e de chuvas (93%). Na otimização da flotação os resultados indicaram uma melhor remoção do material particulado (95%) e cor real (74%) na velocidade ascensional de 5cm/min. Os testes de inter-oxidação resultaram em baixa demanda de cloro, indicando a eficiência da flotação na remoção da matéria orgânica. A caracterização da água do manancial Duas Bocas mostrou qualidade de água satisfatória para águas de abastecimento no período observado. Na avaliação qualiquantitativa do fitoplâncton foram registrados 22 táxons, sendo a Classe Cyanophyceae a mais representativa em riqueza e em densidade relativa total nos dois meses de estudo, destacando o domínio das espécies Synechococcus nidulans e Anabaena sp. Esta última apresenta potencial de produção de neurotoxinas e hepatotoxinas, 9 dos 15 gêneros listados são mencionados como causadores de problemas operacionais como gosto, odor, colmatação dos filtros, entre outros. No estudo comparativo entre duas linhas de tratamento, apesar de um maior gasto com coagulante e alcalinizante, o tratamento 2 (30mg/L Al2(SO4)3 em pH 6,4) mostrou-se adequado nos dois meses estudados (maio e junho). A inter-oxidação apresentou baixa eficiência de remoção dos parâmetros cor aparente, turbidez e absorbâncias 254 e 665, nos tratamentos 1 e 2. O meio filtrante misto, composto com de grãos de areia de tamanho 1,20 a 0,60mm (70%) e 0,60 a 0,30mm (30%) seguido de desinfecção com cloro (5mg Cl2/mL), mostrou-se eficiente na remoção dos parâmetros analisados para os quatro tratamentos estudados, compensando os valores menores de remoção observadas nas etapas anteriores. Todos os tratamentos estudados apresentaram resultados positivos para a formação de clorofórmio e bromodiclorometano, porém abaixo dos limites estabelecidos pela Portaria MS 518/04 para TTHM.
4

Estimativa e aplicação dos coeficientes de dispersão longitudinal e de reaeração em corpos de água naturais /

Soares, Pétrick Anderson, Pinheiro, Adilson, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2011 (has links) (PDF)
Orientador: Adilson Pinheiro. / Dissertação (mestrado) - Universidade Regional de Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Ambiental.
5

Controlo de perdas aparentes em sistemas de abastecimento de água com utilização de telecontagem

Malheiro, Rui Miguel Gonçalves January 2011 (has links)
Tese de mestrado integrado. Engenharia Civil (Hidráulica). Universidade do Porto. Faculdade de Engenharia. 2011
6

Remoção de microcistinas por meio de oxidação química com hipoclorito de sódio e validação do método de análise por cromatografia líquida com detector de massas / Microcystins removal through oxidation with sodium hypochilorite and validation of liquid chromatography coupled with mass spectrometry as analytical method

Nascimento, Maria Martins do 06 December 2011 (has links)
Dissertação (mestrado)-Universidade de Brasília, Programa de Pós-Graduação em Tecnologia Ambiental e Recursos Hídricos, 2011. / Submitted by Albânia Cézar de Melo (albania@bce.unb.br) on 2012-01-26T13:35:50Z No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / Approved for entry into archive by Elzi Bittencourt(elzi@bce.unb.br) on 2012-01-26T14:33:22Z (GMT) No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / Made available in DSpace on 2012-01-26T14:33:22Z (GMT). No. of bitstreams: 1 2011_MariaMartinsNascimento.pdf: 5276362 bytes, checksum: 4153237396eb41bdba98dcc395722010 (MD5) / As florações de cianobatérias provocadas pelo aporte de nutrientes nos corpos de água impactam a qualidade das águas. Esses micro-organismos ao serem lisados liberam toxinas para a água. O tratamento de água convencional - coagulação, floculação, sedimentação e filtração - não é eficiente na remoção dessas cianotoxinas dissolvidas, porém a oxidação no durante a etapa de desinfecção (cloração) pode ser uma alternativa para a remoção desses compostos. Sendo assim, o presente trabalho teve por objetivo estudar o processo de oxidação de microcistinas dissolvidas usando o hipoclorito de sódio como oxidante, avaliando a cinética de oxidação, influência da dose e tempo de contato, bem como a caracterização das microcistinas produzidas pela linhagem NPLJ-4 de Microcystis aeruginosa e a validação o método para determinação de microcistina-LR por cromatografia líquida com detector de massas (CL-MS/MS). Os resultados obtidos sugerem a presença de seis variantes de microcistinas produzidas pela linhagem NPLJ-4, sendo a mais abundante a [D-Leu] MCYST-LR. O método de determinação da MCYSTLR implementado apresentou, na faixa de 1-50 μg L-1, boa linearidade, com coeficiente de ajuste (r) maior que 0,99. A repetitividade do método, obtida mediante a fortificação de amostras com diferentes concentrações de microcistina-LR, apresentou resultados satisfatórios (CV % < 20). Os Limites de Detecção (LOD) e de Quantificação (LOQ) foram inferiores a 1,0 μg L-1 de MCYST-LR, valor máximo permito pela legislação brasileira sobre potabilidade da água, indicando a aplicabilidade do método para o controle de água para consumo humano. Nas condições avaliadas, microcistinas semi-purificadas oxidadas com hipoclorito de sódio em valor de pH 6, os resultados mostraram que a oxidação segue uma cinética de pseudo-primeira ordem em relação à concentração de microcistinas e a eficiência de remoção foi proporcional ao CT (concentração de cloro vezes tempo de contato). Para concentrações de microcistinas de cerca de 100, 40 e 20 μg L-1, os produtos CT mínimos necessários para obtenção de concentrações de microcistinas atendendo o padrão de potabilidade foram, respectivamente, 120, 60 e 30 mg L-1 min. ______________________________________________________________________________ ABSTRACT / Blooms of cyanobacteria caused by nutrients loads to water sources impacts water quality. When these microorganisms are lysed they release toxins into the water. The conventional water treatment, based in coagulation, flocculation, sedimentation and filtration, is not effective in removing these dissolved cyanotoxins, but the oxidation during chlorination can be an alternative for the removal of such microcontaminants. Therefore, this work aimed to study the oxidation of microcystins using sodium hypochlorite as oxidant, evaluating the oxidation kinetics, the influence of dose and oxidation time, as well as the characterization of microcystins variants produced by Microcystis aeruginosa NPLJ-4 strain and optimization and validation of the analytical method for determination of MCYST-LR by liquid chromatography coupled with mass spectrometry (LC-MS/MS). The results indicated the presence of six variants of microcystins produced by the M. aeruginosa NPLJ-4 strain, with the [D-Leu] MCYST-LR being the most abundant toxin. The LC-MS/MS method for quantification of MCYST-LR showed good linearity in the range of 1 to 50 μg L-1, with fitness coefficient (r) > 0.99. The repeatability, obtained by fortifying blank samples with different concentrations of microcystin-LR, was considered satisfactory (CV% < 20). The limits of detection (LOD) and quantification (LOQ) were lower than 1.0 mg L-1 of MCYST-LR, the Brazilian drinking water standard, suggesting the applicability of the method for the drinking water quality control. Under the conditions studied, oxidation of semi-purified microcystins with sodium hypochlorite at pH 6, the results showed that the oxidation followed a pseudo-first order kinetics regarding the microcystins concentration and the removal efficiency was related to CT product (concentration of chlorine times oxidation time). For concentrations of microcystins of around 100, 40 e 20 μg L-1, the minimum CT values of 120, 60 e 30 mg L-1 min, respectively, are necessary to guarantee residual concentrations of microcystins bellow de drinking water standard, 1.0 mg L-1.
7

Estudo da demanda de água não potável e desenvolvimento de um sistema de reuso de água cinza para habitações de interesse social.

SILVA, L. M. 22 February 2013 (has links)
Made available in DSpace on 2018-08-24T22:53:27Z (GMT). No. of bitstreams: 1 tese_6431_Dissertacao_Mestrado_LeaMarinaSilva.pdf: 9850603 bytes, checksum: 892b992c15f52044b8e338a5ffbae903 (MD5) Previous issue date: 2013-02-22 / Este trabalho estuda a demanda de água não potável e o desenvolvimento de um sistema de reúso de águas cinza para Habitações de Interesse Social (HIS). Para tanto, realiza a caracterização do perfil de consumo de água em uma comunidade formada por HIS o Residencial Jabaeté, em Vila Velha (ES); investiga quais ações de conservação de água melhor se aplicam no cotidiano da comunidade em questão, analisando o reúso frente às demais ações avaliadas; e, por fim, propõe algumas configurações possíveis de sistemas de reúso nessa comunidade por meio de projeto arquitetônico, no nível de estudo preliminar. Tais estudos apontaram um consumo médio de água nas HIS estudadas de 79 l/hab. dia e demais índices relativos à demanda de água potável em cada atividade doméstica (a mais representativa é a lavagem de roupas, responsável por aproximadamente 41% do consumo total). A metodologia utilizada foi aplicação de questionários e monitoramento do consumo de água pela leitura de hidrômetros. Através da aplicação de um método de suporte à decisão o Analytic Hierarchy Process (AHP), determinou-se a vantagem de práticas como uso de descarga dual e bacia segregadora de urina sobre a prática do reúso de água cinza. Além disso, foram realizados estudos projetuais de dois tipos de configurações de sistemas de reúso: o sistema descentralizado e o sistema semi-descentralizado, para os quais foram orçados os custos de implantação. Observou-se a vantagem econômica da adoção do sistema semi-descentralizado, cuja implantação pode ser até 112% mais barata que o sistema descentralizado.
8

Aplicação Combinada de Técnica de Otimização e Modelo de Qualidade de Água na Determinação de Eficiências de Sistemas de Tratamento de Efluentes Domésticos: uma Abordagem para Gerenciamento de Bacias Hidrográficas.

VALORY, J. P. L. 03 June 2013 (has links)
Made available in DSpace on 2018-08-24T22:53:29Z (GMT). No. of bitstreams: 1 tese_6735_Dissertação_versão_final.pdf: 1583392 bytes, checksum: b2f56f6be3d8580802ba0c47650969e4 (MD5) Previous issue date: 2013-06-03 / Este trabalho estuda a demanda de água não potável e o desenvolvimento de um sistema de reúso de águas cinza para Habitações de Interesse Social (HIS). Para tanto, realiza a caracterização do perfil de consumo de água em uma comunidade formada por HIS o Residencial Jabaeté, em Vila Velha (ES); investiga quais ações de conservação de água melhor se aplicam no cotidiano da comunidade em questão, analisando o reúso frente às demais ações avaliadas; e, por fim, propõe algumas configurações possíveis de sistemas de reúso nessa comunidade por meio de projeto arquitetônico, no nível de estudo preliminar. Tais estudos apontaram um consumo médio de água nas HIS estudadas de 79 l/hab. dia e demais índices relativos à demanda de água potável em cada atividade doméstica (a mais representativa é a lavagem de roupas, responsável por aproximadamente 41% do consumo total). A metodologia utilizada foi aplicação de questionários e monitoramento do consumo de água pela leitura de hidrômetros. Através da aplicação de um método de suporte à decisão o Analytic Hierarchy Process (AHP), determinou-se a vantagem de práticas como uso de descarga dual e bacia segregadora de urina sobre a prática do reúso de água cinza. Além disso, foram realizados estudos projetuais de dois tipos de configurações de sistemas de reúso: o sistema descentralizado e o sistema semi-descentralizado, para os quais foram orçados os custos de implantação. Observou-se a vantagem econômica da adoção do sistema semi-descentralizado, cuja implantação pode ser até 112% mais barata que o sistema descentralizado. Palavras chave: Consumo residencial de água; Água cinza; Conservação de água; Reúso; Habitação de interesse Social
9

Aplicação de metodologias relacionadas à valoração da água para as bacias dos rios Grande e Paranaíba / Application of methodologies related to water valuation for the Grande and the Paranaíba rivers basins

Oliveira, Andressa Nayara Gomes 31 July 2017 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-11-17T12:12:28Z No. of bitstreams: 1 texto completo.pdf: 1905064 bytes, checksum: 9f2d27e3d96b5f91beb728861b345c0e (MD5) / Made available in DSpace on 2017-11-17T12:12:28Z (GMT). No. of bitstreams: 1 texto completo.pdf: 1905064 bytes, checksum: 9f2d27e3d96b5f91beb728861b345c0e (MD5) Previous issue date: 2017-07-31 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O aumento da demanda pelo uso da água e a diminuição da disponibilidade hídrica tem causado cenários de escassez hídrica, o que pode ocasionar conflitos entre os usuários. A cobrança pelo uso da água proposta pela Lei no 9433/97 visa, portanto, promover a utilização mais racional dos recursos hídricos. No Brasil, a cobrança pelo uso da água já é um instrumento aplicado em algumas bacias hidrográficas. Entretanto, a metodologia atual não considera alguns aspectos importantes para o cálculo da cobrança. Dessa forma, o presente trabalho tem como objetivo a aplicação de metodologias relacionadas à valoração da água para as bacias do rio Grande e do rio Paranaíba, em função do tipo de manancial de captação, da utilização de reservatórios de regularização de vazões, da sazonalidade de vazões e da efetiva demanda hídrica das culturas. Comparou-se também os resultados obtidos com os encontrados por Ramos (2016) e Ribeiro (2016) para a bacia do Paracatu. A utilização dos critérios relacionados à sazonalidade de vazões e ao manancial de captação permitiram associar uma valoração mensal diferenciada ao longo do ano para as bacias do Grande e Paranaíba. Observou-se uma diminuição do custo da água superficial e um aumento do valor da água subterrânea no período chuvoso. Contudo, com a aproximação do período de estiagem, há uma diminuição do desconto da água superficial e do custo da água subterrânea. Vale ressaltar que a bacia do Grande apresentou menor variação sazonal da relação entre os valores de Q 7,10 mensais e anual em comparação com as bacias do Paranaíba e Paracatu. Em relação às efetivas demandas hídricas das culturas, foi possível o desestímulo do uso da água na irrigação no período de menor disponibilidade hídrica, graças à aplicação dos aprimoramentos do fator de uso da água na irrigação. A bacia do Grande apresentou as menores vazões demandadas pelas culturas em ambas as regiões homogêneas, devido a menor evapotranspiração na bacia. Por fim, o fator de deplecionamento pelo uso da água em condições de regularização associou um maior desconto mensal ao usuário, e a alteração da vazão mínima residual possibilitou um aumento expressivo da disponibilidade hídrica sem comprometer as condições à fio d’água. / Increasing in water use demand and the reduction of water availability has caused scenarios of water scarcity, which can lead to conflicts among users. The charge for water use proposed by Brazilian Law 9433/97 aims, therefore, to promote the more rational use of water resources. In Brazil, the charge for water use is already an instrument applied in some watershed. However, the current methodology does not consider some important aspects for charge calculation. Thus, the present study aims the application of methodologies related to water valuation for the Grande and the Paranaíba rivers basins, depending on the type of capitation source, use flow regulation system, seasonal availability of flows and the effective water demand of crops. The results obtained by Ramos (2016) and Ribeiro (2016) for the Paracatu basin were also compared. The use of criteria related to seasonal availability of flows and capitation source allowed to associate distinct monthly valuations throughout the year for Grande and Paranaíba rivers basins. Decreasing in valuation of the surface water and increasing in the groundwater value in the rainy season were verified. However, as the drought period draw nearer, there was a decrease in surface water discount and groundwater cost. It is noteworthy that the Grande basin presented lower seasonal variation between the monthly and annual Q 7,10 values if compared to Paranaíba and Paracatu basins. Regarding the effective water demand of crops, a discouraging of water use for irrigation in the period of less hydric availability was possible with application of improvements in the water use factor in irrigation. Grande basin presented lower flows demanded by the crops in both homogeneous regions, due to the lower evapotranspiration in the basin. Finally, the drawdown factor for water use in regularization conditions led to a higher monthly discount to the user, and the changing of minimum residual flow allowed a significant increase of water availability without compromising the conditions to run of river.
10

Estudo sobre a aplicação da espectrofotometria derivativa na análise de nitrogênio em diversas matrizes de águas / Study on the application in derivative spectrophotometry analysis of nitrogen in several matrices of waters

Silva, Maria do Socorro Pinheiro da January 2013 (has links)
SILVA, M. S. P. Estudo sobre a aplicação da espectrofotometria derivativa na análise de nitrogênio em diversas matrizes de águas. 2013. 116 f. Dissertação (Mestrado em Química) - Centro de Ciências, Universidade Federal do Ceará, Fortaleza, 2013. / Submitted by Daniel Eduardo Alencar da Silva (dealencar.silva@gmail.com) on 2014-11-24T23:43:23Z No. of bitstreams: 1 2013_dis_mspsilva.pdf: 1330387 bytes, checksum: 651f2c3fb1eb3e73ee989537d9bcc349 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa(jairo@ufc.br) on 2016-01-06T18:54:41Z (GMT) No. of bitstreams: 1 2013_dis_mspsilva.pdf: 1330387 bytes, checksum: 651f2c3fb1eb3e73ee989537d9bcc349 (MD5) / Made available in DSpace on 2016-01-06T18:54:42Z (GMT). No. of bitstreams: 1 2013_dis_mspsilva.pdf: 1330387 bytes, checksum: 651f2c3fb1eb3e73ee989537d9bcc349 (MD5) Previous issue date: 2013 / The determination of the levels of nitrates and total nitrogen (TN) in water is an important tool to assess the control levels for the protection of human health as well as to characterize the eutrophication of water bodies. The present work is a study of derivative spectrophotometry (DS) for the determination of nitrate and TN zero-peak method for DS in the second derivative maximum absorption of nitrate (225nm). In this study we evaluated the interferences commonly found in matrices where the methodology was applied, which were mineral water, added salts and surface water (reservoirs and rivers): bicarbonate, carbonate, iron, copper, sulfate, chloride, bromide, iodide, phosphate, sulphate, nitrite and dissolved organic matter (DOM). This methodology was applied in the determination of nitrate in mineral water samples, added salt and water reservoirs monitored by COGERH where the latter matrix was also determined TN. The interfering evaluated showed no interference in the second derivative of nitrate within acceptable limits, with the exception of nitrite and carbonate ions, where it was necessary to remove these by adding a solution of sulfamic acid with HCl. According to the t test (student) paired samples of mineral waters and added salts, which were analyzed nitrate levels both DS as the method of cadmium reduction column with subsequent determination by the method of sulfanilamide, showed no significant differences a confidence level of 95%. For surface water samples, the determination of nitrates by DS proved not to be applicable. Determination of TN already proved to be promising, however preliminary studies suggest that the DOM present in the samples studied the reservoirs presents spectral interference, since such, dams studied showed signs of contamination of allochthonous origin, lying mostly eutrophic. / A determinação dos níveis de nitratos e nitrogênio total (NT) em águas constitui uma ferramenta importante no sentido de avaliar o controle de seus níveis para proteção da saúde humana bem como para caracterizar a eutrofização dos corpos aquáticos. O presente trabalho faz um estudo da espectrofotometria derivativa (ED) para determinação de nitratos e NT pelo método zero-pico por ED, em segunda derivada, no máximo de absorção do nitrato (225nm). Neste estudo foram avaliados os interferentes comumente encontrados nas matrizes onde a metodologia foi aplicada, que foram águas minerais, águas adicionadas de sais e águas superficiais (açudes e rios): bicarbonato, carbonato, ferro, cobre, sulfato, cloreto, brometo, iodeto, fosfato, sulfato, nitrito e matéria orgânica dissolvida (MOD). Esta metodologia foi aplicada na determinação de nitratos em amostras águas minerais, adicionada de sais e águas de açudes monitorados pela COGERH, onde nesta última matriz foi determinado também NT. Os interferentes avaliados não apresentaram interferência na segunda derivada do nitrato dentro de limites aceitáveis, com exceção dos íons nitrito e carbonato, onde foi necessário a remoção destes pela adição de uma solução de ácido sulfâmico com HCl. Segundo o teste t (student) pareado, para amostras de águas minerais e adicionadas sais, que foram analisados os teores de nitratos tanto por ED quanto pelo método da redução em coluna de cádmio com posterior determinação pelo método da sulfanilamida, não apresentaram diferenças significativas a um nível de confiança de 95%. Para as amostras de águas superficiais, a determinação de nitratos por ED demonstrou não ser aplicável. Já determinação de NT demonstrou-se promissora, porém, estudos preliminares sugerem que a MOD presente nas amostras dos açudes estudados apresenta interferência espectral, uma vez que, tais açudes estudados apresentaram indícios de contaminação de origem alóctone, se encontrando, na maioria, eutrofizados.

Page generated in 0.0332 seconds