• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Investigação numérica e experimental do escoamento em válvulas de compressores herméticos

Anhê Junior, Sérgio Antônio [UNESP] 28 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:39Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-28Bitstream added on 2014-06-13T20:30:31Z : No. of bitstreams: 1 anhejunior_sa_me_ilha.pdf: 2550289 bytes, checksum: 4299d702522bdb3a4b51de625099c77e (MD5) / Fundação de Ensino Pesquisa e Extensão de Ilha Solteira (FEPISA) / O presente trabalho refere-se à investigação experimental e numérica do escoamento em difusores radiais, que são usados como modelos de representação de sistemas de válvulas de compressores de refrigeração. Uma bancada experimental é projetada, construída e validada para medir a distribuição de pressão, sobre o disco frontal de um difusor radial de razão de diâmetro 3, para números de Reynolds de 1500 a 9000 e afastamento entre os discos frontal e anterior variando de 0,415mm a 0,705mm aproximadamente. Paralelamente, desenvolve-se um código computacional, baseado na metodologia de Volumes Finitos para malhas desencontradas, para simular o escoamento na geometria do difusor radial. O código computacional é primeiramente validado por meio dos resultados experimentais obtidos da bancada construída. Após sua validação, o código é usado para analisar o escoamento em um difusor de razão de diâmetro igual a 1,4, para números de Reynolds variando de 500 a 2500 e afastamento entre discos na fixa de 0,125 a 1,0mm. Os resultados numéricos mostram o surgimento de recirculação extendendo-se em toda região do difusor. Além disso, os resultados de perfil de pressão sobre o disco frontal fornecem forças e quedas totais de pressão no difusor que aumentam com o número de Reynolds e afastamento entre disco. Esse comportamento produz um ponto de mínima área efetiva de força localizado na faixa de , para números de Reynolds variando de 500 a 1500. Para número de Reynolds mais elevados, , a área efetiva de força sempre aumenta com o aumento do afastamento entre discos. A área efetiva de escoamento, outro parâmetro de interesse para a simulação do compressor, apresenta um crescimento linear com o afastamento entre discos, independentemente do número de Reynolds avaliado. / In this work, an experimental and numerical investigation of the flow in radial diffusers representing the valve system of refrigeration compressor is accomplished. An experimental bench is designed, build, and validated allowing the measurement of the pressure distribution on the frontal disk surface of a radial diffuser with diameter ratio equal to 3, for Reynolds number varying from 1500 to 9000 and distances between disks in the ranges of 0.415 to 0.705mm. In addition, a computational code based on the Finite Volume Methodology for staggered mesh is developed in order to simulate the flow though the radial diffuser. The computational code is firstly validated by using the experimental data obtained from the experimental bench. After its validation, the code is used for analyzing the flow through a radial diffuser with diameter ratio equal to 1.4, for Reynolds numbers varying from 500 to 2500 and distance between disks in the range of 0.125 a 1.0 mm. The numerical results showed recirculation regions extending through the whole diffuser for the majority of the analyzed cases. The pressure profiles on the frontal disk surface produce forces and total pressure drops through the diffuser that increase with both Reynolds number and distance between disks. There is a minimum effective force area in the range of , for Reynolds numbers varying from 500 a 1500. For higher Reynolds numbers, , the effective force area always increases for increasing distance between disks. The effective flow area, another parameter used for simulating the compressor, increases linearly with the distance between disks, independently of the Reynolds number.
2

Absorção de dióxido de carbono em soluções aquosas de aminas em uma coluna de parede molhada com promotor de película. / Carbon dioxide absorption in amines aqueous solutions in a wetted wall column with film promoter.

Rodriguez Flores, Henry Alexander 11 March 2011 (has links)
O processo de absorção do CO2 em soluções aquosas de alcanolaminas foi estudado em uma coluna de parede molhada empregando-se uma tela metálica, de 28 mesh, como promotor de película e operando em contracorrente. As alcanolaminas testadas nos diferentes experimentos foram: monoetanolamina (MEA), 2-amino-2-metil-1-propanol (AMP) e piperazina (PZ). Os experimentos de absorção foram realizados nas soluções aquosas individuais da MEA e AMP; e, nas misturas MEA:AMP e AMP:PZ; visando avaliar a velocidade de absorção do CO2 em diferentes vazões do líquido, a saber: 3.10-7, 6.10-7 e 10.10-7 m3/s. O presente sistema de absorção foi caracterizado através da determinação dos principais parâmetros de transferência de massa: área interfacial efetiva, coeficiente de transferência individual da fase gasosa e o coeficiente volumétrico global médio de transferência de massa. Determinou-se a área interfacial efetiva da coluna, por meio da absorção do CO2 diluído em ar em uma solução aquosa de NaOH, para as diferentes vazões de líquido, sendo os resultados obtidos igual a 106, 126 e 144 m2/m3, respectivamente. O coeficiente volumétrico de transferência de massa da fase gasosa foi determinado por meio da absorção de SO2 diluído em ar em uma solução aquosa de NaOH. Os resultados experimentais mostram que o coeficiente volumétrico individual de transferência de massa e a área interfacial são função da vazão do líquido. As velocidades de absorção do CO2 diluído em ar, em soluções de aminas e suas misturas foram determinadas experimentalmente para diferentes vazões de líquido, sendo os resultados expressos na forma de coeficientes globais de transferência de massa e parâmetros cinético-difusivos da fase líquida. As velocidades de absorção em MEA são bem superiores aos de AMP e NaOH. No caso das misturas foram obtidas velocidades superiores em comparação às das aminas individuais. A velocidade de absorção em AMP é fortemente incrementada na presença de PZ, mesmo em baixa concentração. / The CO2 absorption process in alkanolamine aqueous solutions was studied in a wetted wall column employing a film promotor of thin stainless steel woven wire, 28 mesh, which was operated in countercurrent. The tested alkanolamines were monoethanolamine (MEA), 2-amino-2-methyl-1-propanol (AMP) and piperazine (PZ). The absorption experiments were performed in individual aqueous solutions of MEA and AMP and the mixtures MEA:AMP and AMP:PZ, with the aim of evaluating the CO2 absorption rate in different liquid flow rates, namely: 3.10-7, 6.10-7 e 10.10-7 m3/s. This absorption system was characterized through determining of the main parameters of mass transfer: effective interfacial area, individual mass transfer coefficient of the gas phase and the average overall mass transfer volumetric coefficient. The effective interfacial area was determined by the absorption of CO2 diluted in air into an aqueous solution of NaOH for the different liquid flow rates, and the results obtained are 106, 126 and 144 m2/m3, respectively. The mass transfer volumetric coefficient of the gas phase was determined by chemical method of the absorption of SO2 diluted in air into an aqueous solution of NaOH. The experimental results show that the individual mass transfer coefficient and interfacial area are a function of liquid flow rate. On the other hand, the results of the performance of CO2 absorption into amine aqueous solutions were expressed in function of the average overall mass transfer volumetric coefficient and liquid phase diffusive kinetic parameters, which were measured experimentally for different liquid flow rates. The absorption rate in MEA are higher in comparison with AMP and NaOH. In the case of the blended, the absorption rate in AMP is enhanced by piperazine, even in low concentration.
3

Absorção de dióxido de carbono em soluções aquosas de aminas em uma coluna de parede molhada com promotor de película. / Carbon dioxide absorption in amines aqueous solutions in a wetted wall column with film promoter.

Henry Alexander Rodriguez Flores 11 March 2011 (has links)
O processo de absorção do CO2 em soluções aquosas de alcanolaminas foi estudado em uma coluna de parede molhada empregando-se uma tela metálica, de 28 mesh, como promotor de película e operando em contracorrente. As alcanolaminas testadas nos diferentes experimentos foram: monoetanolamina (MEA), 2-amino-2-metil-1-propanol (AMP) e piperazina (PZ). Os experimentos de absorção foram realizados nas soluções aquosas individuais da MEA e AMP; e, nas misturas MEA:AMP e AMP:PZ; visando avaliar a velocidade de absorção do CO2 em diferentes vazões do líquido, a saber: 3.10-7, 6.10-7 e 10.10-7 m3/s. O presente sistema de absorção foi caracterizado através da determinação dos principais parâmetros de transferência de massa: área interfacial efetiva, coeficiente de transferência individual da fase gasosa e o coeficiente volumétrico global médio de transferência de massa. Determinou-se a área interfacial efetiva da coluna, por meio da absorção do CO2 diluído em ar em uma solução aquosa de NaOH, para as diferentes vazões de líquido, sendo os resultados obtidos igual a 106, 126 e 144 m2/m3, respectivamente. O coeficiente volumétrico de transferência de massa da fase gasosa foi determinado por meio da absorção de SO2 diluído em ar em uma solução aquosa de NaOH. Os resultados experimentais mostram que o coeficiente volumétrico individual de transferência de massa e a área interfacial são função da vazão do líquido. As velocidades de absorção do CO2 diluído em ar, em soluções de aminas e suas misturas foram determinadas experimentalmente para diferentes vazões de líquido, sendo os resultados expressos na forma de coeficientes globais de transferência de massa e parâmetros cinético-difusivos da fase líquida. As velocidades de absorção em MEA são bem superiores aos de AMP e NaOH. No caso das misturas foram obtidas velocidades superiores em comparação às das aminas individuais. A velocidade de absorção em AMP é fortemente incrementada na presença de PZ, mesmo em baixa concentração. / The CO2 absorption process in alkanolamine aqueous solutions was studied in a wetted wall column employing a film promotor of thin stainless steel woven wire, 28 mesh, which was operated in countercurrent. The tested alkanolamines were monoethanolamine (MEA), 2-amino-2-methyl-1-propanol (AMP) and piperazine (PZ). The absorption experiments were performed in individual aqueous solutions of MEA and AMP and the mixtures MEA:AMP and AMP:PZ, with the aim of evaluating the CO2 absorption rate in different liquid flow rates, namely: 3.10-7, 6.10-7 e 10.10-7 m3/s. This absorption system was characterized through determining of the main parameters of mass transfer: effective interfacial area, individual mass transfer coefficient of the gas phase and the average overall mass transfer volumetric coefficient. The effective interfacial area was determined by the absorption of CO2 diluted in air into an aqueous solution of NaOH for the different liquid flow rates, and the results obtained are 106, 126 and 144 m2/m3, respectively. The mass transfer volumetric coefficient of the gas phase was determined by chemical method of the absorption of SO2 diluted in air into an aqueous solution of NaOH. The experimental results show that the individual mass transfer coefficient and interfacial area are a function of liquid flow rate. On the other hand, the results of the performance of CO2 absorption into amine aqueous solutions were expressed in function of the average overall mass transfer volumetric coefficient and liquid phase diffusive kinetic parameters, which were measured experimentally for different liquid flow rates. The absorption rate in MEA are higher in comparison with AMP and NaOH. In the case of the blended, the absorption rate in AMP is enhanced by piperazine, even in low concentration.

Page generated in 0.054 seconds